2CCS571001R0024 ABB S401MC2 S401M-C2 MCB 10kA 1P Type C 2A

2CCS571001R0024 ABB S401MC2 S401M-C2 MCB 10kA 1P Type C 2A

ABB S401MC2 S401M-C2 is a single-pole 2 A Type C miniature circuit breaker with 10 kA Icn and 25 kA Icu for the SMISSLINE TP plug-in system.

SKU: 2CCS571001R0024Alt SKU: S401MC2MPN: 2CCS571001R0024
Price
List Price £46.03 ex VAT
Your Price (ex VAT) Save 35%
£29.92 35% OFF
You save £16.11 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £29.92
Trade pricing is personalised to your account

Manufacturer Lead Time

£29.92

Why Choose the ABB S401MC2 Miniature Circuit Breaker?

The ABB S401MC2, type designation S401M-C2, is a single-pole miniature circuit breaker (MCB) designed for the ABB SMISSLINE TP plug-in system. Rated at 2 A with a Type C tripping characteristic, it provides overload and short-circuit protection for low-current electrical circuits in commercial, industrial and critical-power applications.

The S401M-C2 has a rated short-circuit capacity of 10 kA according to EN 60898-1 and an ultimate short-circuit breaking capacity of 25 kA according to IEC/EN 60947-2. Its current-limiting design combines a delayed thermal tripping mechanism for overload protection with an electromagnetic tripping mechanism for short-circuit protection.

Purpose-designed for the SMISSLINE TP system, the S401M-C2 uses ABB's plug-in architecture for efficient installation within compatible distribution assemblies. The breaker occupies 1 module, weighs approximately 110 g and is supplied by ABB in packaging units of 10 pieces.

Key Advantages

  • 2 A rated current for low-current branch, auxiliary and control circuits.
  • Type C tripping characteristic suitable for circuits with moderate normal inrush currents.
  • 10 kA breaking capacity according to EN 60898-1.
  • 25 kA ultimate breaking capacity according to IEC/EN 60947-2.
  • Provides combined thermal overload and electromagnetic short-circuit protection.
  • Current-limiting MCB design helps restrict fault-current energy.
  • Compact single-pole, 1-module construction.
  • Purpose-designed for the ABB SMISSLINE TP plug-in system.

Key Features

  • ABB S401M-C2 miniature circuit breaker.
  • 1-pole configuration.
  • 2 A rated current.
  • C tripping characteristic.
  • 10 kA Icn according to EN 60898-1.
  • 25 kA Icu according to IEC/EN 60947-2.
  • Delayed thermal tripping mechanism for overload protection.
  • Electromagnetic tripping mechanism for short-circuit protection.
  • 1-module format.
  • Direct plug-in integration with compatible SMISSLINE TP assemblies.

Reliable Current-Limiting Circuit Protection

The ABB S401M-C2 uses two complementary tripping mechanisms to protect connected circuits. A delayed thermal mechanism responds to sustained overload conditions, while an electromagnetic mechanism provides rapid operation during short circuits. This current-limiting construction helps reduce the electrical stress associated with high fault currents.

With a 2 A Type C rating, 10 kA Icn according to EN 60898-1 and 25 kA Icu according to IEC/EN 60947-2, the S401M-C2 provides robust protection for low-current circuits. Its SMISSLINE TP plug-in format supports efficient installation and replacement within compatible modular distribution systems.

Typical Applications

  • ABB SMISSLINE TP distribution assemblies.
  • Industrial automation and control circuits.
  • Low-current auxiliary circuits.
  • Signalling and monitoring equipment.
  • Machine and process-control panels.
  • Commercial electrical distribution systems.
  • Industrial and critical-power distribution applications.
  • Circuits requiring 2 A Type C protection with 10 kA Icn.

Technical Specifications

Product group SMISSLINE Plug-in System
Series S400 M-C
SKU S401MC2
ABB order code 2CCS571001R0024
EAN / GTIN 7612270101351
Product type Miniature circuit breaker (MCB)
Number of poles 1
Rated current 2 A
Tripping characteristic C
Rated short-circuit capacity Icn, EN 60898-1 10 kA
Ultimate short-circuit breaking capacity Icu, IEC/EN 60947-2 25 kA
Protection functions Overload and short-circuit protection
Module width 1 module
Weight 110 g
Packaging unit 10 pieces
System ABB SMISSLINE TP plug-in system

Frequently Asked Questions

What is the ABB S401MC2 used for?

The ABB S401MC2 is a single-pole miniature circuit breaker designed to protect compatible electrical circuits against overload and short-circuit currents within ABB SMISSLINE TP distribution systems.

What is the current rating of the ABB S401M-C2?

The S401M-C2 has a rated current of 2 A and uses a Type C tripping characteristic.

What is the breaking capacity of the ABB S401M-C2?

The S401M-C2 has a rated short-circuit capacity of 10 kA according to EN 60898-1 and an ultimate short-circuit breaking capacity of 25 kA according to IEC/EN 60947-2.

How does the ABB S401M-C2 provide circuit protection?

The breaker uses a delayed thermal tripping mechanism for overload protection and an electromagnetic tripping mechanism for short-circuit protection.

Which distribution system is the ABB S401M-C2 designed for?

The S401M-C2 is designed for the ABB SMISSLINE TP plug-in system and occupies 1 module within a compatible assembly.

Trusted ABB Protection for SMISSLINE Distribution

ABB S400 M miniature circuit breakers combine current-limiting overload and short-circuit protection with the modular plug-in advantages of the SMISSLINE TP system for professional electrical distribution.