2CCS562001R1978 ABB S402M-UCZ1.6 DC MCB 2P Type Z 1.6 A

2CCS562001R1978 ABB S402M-UCZ1.6 DC MCB 2P Type Z 1.6 A

ABB S402M-UCZ1.6 is a two-pole 1.6 A Z-characteristic miniature circuit breaker for DC applications up to 440 V DC with 50 kA ultimate short-circuit breaking capacity in the SMISSLINE TP system.

SKU: 2CCS562001R1978Alt SKU: S402MUCZ1.6MPN: 2CCS562001R1978
Price
List Price £170.96 ex VAT
Your Price (ex VAT) Save 35%
£111.12 35% OFF
You save £59.84 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £111.12
Trade pricing is personalised to your account

Manufacturer Lead Time

£111.12

Why Choose the ABB S402M-UCZ1.6 DC Miniature Circuit Breaker?

The ABB S402M-UCZ1.6 is a two-pole miniature circuit breaker (MCB) designed for DC circuit protection within the ABB SMISSLINE TP plug-in distribution system. It combines overload and short-circuit protection with simultaneous two-pole switching for demanding low-current DC circuits.

As part of the ABB S400 M-UC series, the S402M-UCZ1.6 has a 1.6 A rated current and a sensitive Z tripping characteristic. The two-pole configuration is designed for applications up to 440 V DC, making it suitable for electronic, instrumentation, control and automation circuits requiring responsive overcurrent protection.

The S402M-UCZ1.6 provides a rated ultimate short-circuit breaking capacity of 50 kA for this low-current variant. It occupies two modules, weighs approximately 221 g according to current ABB catalogue data and is identified by ABB order code 2CCS562001R1978 and EAN / GTIN 7612270110278.

Key Advantages

  • Purpose-designed for DC circuit protection.
  • Two-pole configuration for simultaneous switching and protection.
  • 1.6 A rated current for low-current DC circuits.
  • Sensitive Z tripping characteristic for electronic and control applications.
  • Suitable for two-pole applications up to 440 V DC.
  • High 50 kA ultimate short-circuit breaking capacity for this variant.
  • Compact two-module construction.
  • Plug-in design supports efficient integration with the ABB SMISSLINE TP system.

Key Features

  • ABB SMISSLINE TP S400 M-UC series.
  • Two-pole DC miniature circuit breaker.
  • 1.6 A rated current.
  • Type Z tripping characteristic.
  • Suitable for two-pole DC applications up to 440 V DC.
  • 50 kA Icu for the 1.6 A variant.
  • Designed for protection of sensitive electronic and control circuits.
  • SMISSLINE plug-in mounting.
  • Two-module format.
  • Designed in accordance with IEC/EN 60947-2.

Sensitive Two-Pole DC Circuit Protection

Direct-current circuits require protective devices specifically designed to interrupt DC fault currents reliably. ABB's S400 M-UC range combines thermal overload protection and magnetic short-circuit protection with the SMISSLINE TP plug-in architecture, providing dedicated protection for DC distribution and control applications.

The Z characteristic provides sensitive magnetic operation at relatively low multiples of rated current, making the S402M-UCZ1.6 particularly suitable for electronic equipment, instrumentation and control circuits. Its two-pole configuration also supports DC applications up to 440 V DC when installed in accordance with ABB's specified connection arrangement.

Typical Applications

  • ABB SMISSLINE TP DC distribution systems.
  • Sensitive electronic circuits.
  • Industrial DC control circuits.
  • Instrumentation and measurement systems.
  • Automation and PLC auxiliary supplies.
  • DC signalling and monitoring circuits.
  • Control-panel DC power distribution.
  • Commercial and industrial low-voltage DC installations.

Technical Specifications

Product group SMISSLINE Plug-in System
Series S400 M-UC
ABB order code 2CCS562001R1978
EAN / GTIN 7612270110278
Product type Miniature circuit breaker (MCB)
Application DC circuit protection
Number of poles 2
Rated current 1.6 A
Tripping characteristic Z
Maximum two-pole DC application voltage 440 V DC
Rated ultimate short-circuit capacity Icu 50 kA
Module width 2 modules
Weight approx. 221 g
Mounting system ABB SMISSLINE TP plug-in system
Standard IEC/EN 60947-2

Frequently Asked Questions

What is the ABB S402M-UCZ1.6 used for?

The ABB S402M-UCZ1.6 is a two-pole DC miniature circuit breaker designed to provide overload and short-circuit protection for sensitive low-current circuits within compatible ABB SMISSLINE TP systems.

What is the rated current of the S402M-UCZ1.6?

The S402M-UCZ1.6 has a rated current of 1.6 A and uses a sensitive Z tripping characteristic.

What DC voltage can the ABB S402M-UCZ1.6 be used at?

The two-pole S402M-UCZ configuration is designed for applications up to 440 V DC when connected in accordance with ABB's specified DC circuit arrangement.

What is the breaking capacity of the ABB S402M-UCZ1.6?

ABB catalogue data specifies a rated ultimate short-circuit breaking capacity of 50 kA for the S402M-UCZ1.6.

What is a Type Z tripping characteristic used for?

A Z characteristic provides sensitive magnetic overcurrent operation and is particularly suitable for electronic, instrumentation and control circuits where rapid protection at relatively low fault-current multiples is required.

Trusted ABB DC Circuit Protection

ABB SMISSLINE TP S400 M-UC miniature circuit breakers combine dedicated DC protection with modular plug-in installation, providing dependable overload and short-circuit protection for electronic, control, automation and industrial distribution applications.