2CCS562001R1018 ABB S402M-UCZ1 DC MCB 2P Type Z 1 A

2CCS562001R1018 ABB S402M-UCZ1 DC MCB 2P Type Z 1 A

ABB S402M-UCZ1 is a two-pole 1 A Type Z DC miniature circuit breaker providing sensitive overload and short-circuit protection with up to 440 V DC operation in the SMISSLINE TP plug-in system.

SKU: 2CCS562001R1018Alt SKU: S402MUCZ1MPN: 2CCS562001R1018
Price
List Price £170.96 ex VAT
Your Price (ex VAT) Save 35%
£111.12 35% OFF
You save £59.84 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £111.12
Trade pricing is personalised to your account

Manufacturer Lead Time

£111.12

Why Choose the ABB S402M-UCZ1 DC Miniature Circuit Breaker?

The ABB S402M-UCZ1 is a high-performance two-pole miniature circuit breaker (MCB) designed for reliable protection of DC circuits within the ABB SMISSLINE TP plug-in distribution system. With a 1 A rated current and sensitive Type Z tripping characteristic, it protects conductors and connected equipment against overload and short-circuit conditions.

As part of the ABB S400M-UC series, the S402M-UCZ1 combines thermal-magnetic circuit protection with the flexibility of the SMISSLINE TP plug-in architecture. Its two-pole configuration enables simultaneous switching and protection of two conductors, while the plug-in design supports efficient installation, maintenance and modification of compatible distribution assemblies.

The S402M-UCZ1 supports two-pole operation up to 440 V DC and has a 1 A rated current. Its Type Z characteristic is particularly suited to sensitive control, electronic, instrumentation and auxiliary circuits where rapid magnetic operation at relatively low fault-current multiples is required.

Key Advantages

  • Dedicated two-pole miniature circuit breaker for DC circuit protection.
  • 1 A rated current for low-current control and auxiliary circuits.
  • Type Z tripping characteristic suited to sensitive electronic equipment.
  • Supports two-pole operation up to 440 V DC.
  • Provides combined overload and short-circuit protection.
  • SMISSLINE TP plug-in construction supports efficient installation, replacement and system expansion.

Key Features

  • ABB S400M-UC SMISSLINE TP series.
  • 1 A rated current.
  • Type Z tripping characteristic.
  • 2-pole configuration.
  • Designed for DC circuit protection.
  • Up to 440 V DC with two-pole connection.
  • Thermal-magnetic overload and short-circuit protection.
  • IP20 protection rating.
  • SMISSLINE TP plug-in mounting for modular distribution assemblies.

Sensitive Protection for DC Control Circuits

Miniature circuit breakers automatically disconnect electrical circuits when overload or short-circuit currents exceed safe operating limits. The ABB S402M-UCZ1 uses thermal-magnetic protection to provide dependable interruption of sustained overloads and high fault currents in low-current DC circuits.

The Type Z characteristic provides sensitive magnetic tripping, making this breaker particularly suitable for electronic equipment, control systems, instrumentation and other circuits where connected components require rapid fault protection. Its two-pole configuration and SMISSLINE TP plug-in mounting also support flexible and service-friendly DC distribution designs.

Typical Applications

  • Industrial DC control circuits.
  • Electronic equipment protection.
  • PLC and automation auxiliary circuits.
  • Instrumentation and measurement systems.
  • Low-current DC signalling and monitoring circuits.
  • ABB SMISSLINE TP plug-in distribution assemblies.

Technical Specifications

Series S400M-UC / SMISSLINE TP
Order code 2CCS562001R1018
EAN / GTIN 7612270110261
Product type DC miniature circuit breaker (MCB)
Number of poles 2
Rated current 1 A
Tripping characteristic Type Z
Current type DC
Maximum DC voltage 440 V DC, 2-pole connection
Protection rating IP20
Module width 2 modules
Width approx. 36 mm
Height approx. 91 mm
Depth approx. 75 mm
Weight approx. 221 g
Operating temperature -25 to +55 °C
Standard IEC/EN 60947-2
Mounting system ABB SMISSLINE TP plug-in system

Frequently Asked Questions

What is the ABB S402M-UCZ1 used for?

The S402M-UCZ1 is a two-pole DC miniature circuit breaker designed to protect sensitive low-current circuits against overload and short-circuit conditions.

What is the rated current of the S402M-UCZ1?

The ABB S402M-UCZ1 has a rated current of 1 A.

What tripping characteristic does the S402M-UCZ1 have?

The breaker has a Type Z tripping characteristic, making it particularly suitable for sensitive electronic, control and instrumentation circuits.

What DC voltage can the ABB S402M-UCZ1 handle?

The S402M-UCZ1 supports operation up to 440 V DC when used in the specified two-pole configuration.

What mounting system does the S402M-UCZ1 use?

The breaker uses the ABB SMISSLINE TP plug-in system, enabling modular installation and efficient replacement within compatible electrical distribution assemblies.

Trusted ABB DC Circuit Protection

ABB S400M-UC miniature circuit breakers combine dependable overcurrent protection with the flexible SMISSLINE TP plug-in architecture, supporting efficient protection of DC control, automation and distribution circuits.