2CCS248356R0001 ABB S804U-UCZ10 MCB 10kA 4P Type Z 10A UL489

2CCS248356R0001 ABB S804U-UCZ10 MCB 10kA 4P Type Z 10A UL489

ABB S804U-UCZ10 is a four-pole 10 A Z-characteristic UL 489 miniature circuit breaker with a 10 kA short-circuit interrupting rating for sensitive branch circuit and industrial equipment protection.

SKU: 2CCS248356R0001Alt SKU: S804UUCZ10MPN: 2CCS248356R0001
Price
List Price £811.25 ex VAT
Your Price (ex VAT) Save 35%
£527.31 35% OFF
You save £283.94 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £527.31
Trade pricing is personalised to your account

Manufacturer Lead Time

£527.31

Why Choose the ABB S804U-UCZ10 MCB?

The ABB S804U-UCZ10 is a high-performance four-pole miniature circuit breaker (MCB) designed for demanding industrial electrical distribution, control and equipment protection applications. Part of the ABB S800U high-performance circuit breaker range, it provides reliable overload and short-circuit protection while meeting the requirements of UL 489 for branch circuit protection.

This circuit breaker has a rated current of 10 A and a sensitive Z tripping characteristic. The Z characteristic is designed for circuits containing sensitive equipment where rapid magnetic operation at relatively low multiples of rated current is required, making it particularly suitable for electronic equipment, control circuits, semiconductor loads and other applications requiring sensitive overcurrent protection.

With a 10 kA short-circuit interrupting rating and a four-pole configuration, the S804U-UCZ10 provides coordinated multipole protection and switching for demanding electrical systems. ABB order code 2CCS248356R0001 uniquely identifies this 10 A Z-characteristic UL 489 circuit breaker.

Key Advantages

  • High-performance UL 489 miniature circuit breaker for branch circuit protection.
  • 10 A rated current for sensitive control and equipment circuits.
  • Z tripping characteristic provides sensitive magnetic overcurrent protection.
  • 10 kA short-circuit interrupting rating.
  • Four-pole configuration for coordinated multipole protection and switching.
  • Provides dependable overload and short-circuit protection.
  • Well suited to sensitive electronic, control and semiconductor loads.
  • Part of ABB's robust S800U high-performance circuit protection platform.

Key Features

  • ABB S800U high-performance circuit breaker series.
  • 4-pole circuit breaker.
  • 10 A rated current.
  • Z tripping characteristic.
  • 10 kA short-circuit interrupting rating.
  • UL 489 branch circuit breaker construction.
  • Thermal-magnetic overload and short-circuit protection.
  • Sensitive instantaneous protection for equipment with low permissible overcurrents.
  • Suitable for industrial control and electrical distribution applications.
  • Provides circuit protection, switching and isolation functions.

Reliable Protection for Sensitive Electrical Loads

Miniature circuit breakers protect conductors and connected equipment by automatically interrupting current when overload or short-circuit conditions occur. The ABB S804U-UCZ10 combines thermal overload protection with fast magnetic short-circuit operation, providing dependable protection for four-pole circuits and sensitive connected equipment.

The Z characteristic responds at lower multiples of rated current than characteristics intended for loads with high starting currents. This makes the S804U-UCZ10 particularly useful for electronic equipment, control systems and other sensitive loads where limiting fault-current exposure is important. Its UL 489 construction enables use as a branch circuit protective device in appropriate installations.

Typical Applications

  • Industrial control circuits.
  • Sensitive electronic equipment protection.
  • Semiconductor and automation equipment circuits.
  • Industrial electrical distribution systems.
  • Control panels and switchboards.
  • UL 489 branch circuit protection applications.
  • Circuits requiring sensitive Z-characteristic overcurrent protection.

Technical Specifications

Tick the specs you need, then view products that match.

Certification UL 489
Series S800U
ABB order code 2CCS248356R0001
Product type Miniature circuit breaker (MCB)
Number of poles 4
Rated current 10 A
Tripping characteristic Z
Short-circuit interrupting rating 10 kA
Protection function Overload and short-circuit protection
Trip technology Thermal-magnetic
Standard / approval UL 489
Application Branch circuit and equipment protection
Product group S800 / S800P / S750 MCB

Frequently Asked Questions

What is the ABB S804U-UCZ10 used for?

The S804U-UCZ10 provides overload and short-circuit protection for branch circuits and sensitive electrical loads, including industrial control, electronic and automation equipment.

What is the rated current of the ABB S804U-UCZ10?

The ABB S804U-UCZ10 has a rated current of 10 A.

What tripping characteristic does the S804U-UCZ10 use?

The breaker uses a Z tripping characteristic, providing sensitive magnetic operation for circuits and equipment that require protection against relatively low overcurrent levels.

What is the short-circuit rating of the ABB S804U-UCZ10?

The S804U-UCZ10 has a short-circuit interrupting rating of 10 kA.

Is the ABB S804U-UCZ10 a UL 489 circuit breaker?

Yes. The S804U-UCZ10 is specified as a UL 489 circuit breaker for branch circuit protection in suitable electrical installations.

Trusted High-Performance Protection from ABB

ABB S800U circuit breakers combine high-performance thermal-magnetic protection with configurations designed for demanding branch circuit applications, providing dependable protection for industrial control, distribution and sensitive electrical loads.