2CCG001772R0001 ABB FS402MK-C32/0.03 RCBO 32 A 30 mA Type F

2CCG001772R0001 ABB FS402MK-C32/0.03 RCBO 32 A 30 mA Type F

ABB FS402MK-C32/0.03 is a 32 A C-curve Type F AP-R plug-in RCBO with 30 mA residual-current sensitivity and 10 kA breaking capacity for the SMISSLINE TP system.

SKU: 2CCG001772R0001Alt SKU: FS402MKC320.03MPN: 2CCG001772R0001
Price
List Price £376.68 ex VAT
Your Price (ex VAT) Save 35%
£244.84 35% OFF
You save £131.84 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £244.84
Trade pricing is personalised to your account

Manufacturer Lead Time

£244.84

Why Choose the ABB FS402MK-C32/0.03 RCBO?

The ABB FS402MK-C32/0.03 is a high-performance plug-in residual current circuit breaker with overcurrent protection (RCBO) designed for the ABB SMISSLINE TP distribution system. Combining overload, short-circuit and residual-current protection in one compact device, it provides comprehensive protection for single-phase final circuits in commercial, industrial and building electrical installations.

As part of the ABB FS402 series, this RCBO features Type F residual-current detection with AP-R high-immunity characteristics, helping provide dependable protection while reducing unwanted tripping. The protected neutral and SMISSLINE TP plug-in design support safe circuit isolation and efficient installation within compatible distribution assemblies.

With a 32 A rated current, C tripping characteristic and 30 mA residual-current sensitivity, the FS402MK-C32/0.03 is designed for modern final circuits requiring combined personal, equipment and overcurrent protection. It provides a rated breaking capacity of 10 kA according to IEC/EN 61009-1 and incorporates an earth fault indicator to distinguish residual-current trips.

Key Advantages

  • Combines residual-current, overload and short-circuit protection in one device.
  • 32 A rated current with C tripping characteristic.
  • 30 mA residual-current sensitivity for additional protection against electric shock.
  • Type F AP-R high-immunity protection helps minimise unwanted tripping.
  • 10 kA rated breaking capacity according to IEC/EN 61009-1.
  • Integrated earth fault indicator (DTI) assists with identifying residual-current trips.
  • Direct plug-in connection to the ABB SMISSLINE TP system simplifies installation and maintenance.

Key Features

  • ABB FS402 SMISSLINE TP RCBO series.
  • 32 A rated current.
  • C tripping characteristic.
  • 30 mA rated residual operating current.
  • Type F residual-current detection with AP-R high immunity.
  • 1P+N configuration with protected neutral.
  • 10 kA breaking capacity according to IEC/EN 61009-1.
  • Contact position indication and dedicated earth fault trip indication.
  • SMISSLINE TP plug-in mounting for efficient installation and replacement.

Integrated Circuit and Residual-Current Protection

RCBOs combine the protective functions of a miniature circuit breaker and a residual-current device. The ABB FS402MK-C32/0.03 therefore protects connected circuits against overload and short-circuit currents while also detecting earth leakage conditions that can create electric-shock and fire risks.

The Type F AP-R design provides enhanced residual-current detection and high immunity to unwanted tripping, supporting continuity of service with modern electrical loads. Its integrated earth fault indicator provides a clear visual indication following differential tripping, while the SMISSLINE TP plug-in system supports efficient installation, maintenance and modification of electrical distribution assemblies.

Typical Applications

  • Single-phase final circuit protection.
  • Commercial and industrial distribution boards.
  • Building electrical distribution systems.
  • Circuits supplying resistive and inductive loads.
  • Modern loads requiring Type F residual-current protection.
  • ABB SMISSLINE TP modular distribution assemblies.

Technical Specifications

Series FS402 / SMISSLINE TP
Order code 2CCG001772R0001
EAN 7612271522414
Product type Residual current circuit breaker with overcurrent protection (RCBO)
Number of poles 1P+N, protected neutral
Rated current 32 A
Tripping characteristic C
Residual-current type Type F, AP-R high immunity
Rated residual operating current 30 mA
Rated voltage 240 / 415 V AC
Rated frequency 50 / 60 Hz
Rated breaking capacity 10 kA according to IEC/EN 61009-1
Ultimate breaking capacity Icu 15 kA according to IEC/EN 60947-2
Service breaking capacity Ics 7.5 kA according to IEC/EN 60947-2
Insulation voltage 500 V
Overvoltage category III
Pollution degree 2
Protection rating IP20
Width 3 modules / 54 mm
Dimensions (H × W × D) approx. 91 × 54 × 68 mm
Weight approx. 0.312 kg
Standards IEC/EN 61009-1, IEC/EN 61009-2-1, IEC/EN 62423
Mounting system ABB SMISSLINE TP plug-in system

Frequently Asked Questions

What is the ABB FS402MK-C32/0.03 used for?

It is a plug-in RCBO designed to provide overload, short-circuit and residual-current protection for single-phase final circuits in ABB SMISSLINE TP electrical distribution systems.

What is the rated current of the FS402MK-C32/0.03?

The RCBO has a rated current of 32 A with a C tripping characteristic.

What residual-current sensitivity does this RCBO provide?

The FS402MK-C32/0.03 has a rated residual operating current of 30 mA.

What residual-current type is the FS402MK-C32/0.03?

It is a Type F AP-R high-immunity RCBO, providing residual-current protection while helping improve resistance to unwanted tripping.

Does the FS402MK-C32/0.03 provide earth fault trip indication?

Yes. The RCBO incorporates a dedicated earth fault indicator that helps identify when the device has operated because of a residual-current fault.

Trusted ABB Circuit Protection

ABB SMISSLINE TP protective devices combine modular plug-in installation with comprehensive circuit protection, supporting flexible, safe and maintainable low-voltage electrical distribution systems.