ABB FS402MKB250.03 FS402MK-B25/0.03 is a 2-pole Type F AP-R high-immunity 25 A B-curve 30 mA RCBO with 10 kA breaking capacity for the SMISSLINE TP plug-in system.

SKU: 2CCG001765R0001Alt SKU: FS402MKB250.03MPN: 2CCG001765R0001
Price
List Price £263.41 ex VAT
Your Price (ex VAT) Save 35%
£171.22 35% OFF
You save £92.19 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £171.22
Trade pricing is personalised to your account

Manufacturer Lead Time

£171.22

Why Choose the ABB FS402MKB250.03 RCBO?

The ABB FS402MKB250.03, type designation FS402MK-B25/0.03, is a compact 2-pole residual current circuit breaker with overcurrent protection (RCBO) designed for the ABB SMISSLINE TP plug-in system. It combines overload, short-circuit and residual-current protection in a single device for single-phase electrical distribution circuits.

This FS402 series RCBO has a 25 A rated current, B tripping characteristic and 30 mA rated residual operating current. It uses a Type F AP-R high-immunity residual-current characteristic, providing enhanced resistance to unwanted tripping and protection suitable for circuits containing modern electronic loads.

With a 240 V AC rated operational voltage and 10 kA rated short-circuit breaking capacity according to IEC/EN 61009-1, the FS402MK-B25/0.03 provides dependable combined circuit protection. Its protected neutral and SMISSLINE TP plug-in construction support efficient installation and servicing, while the DTI function provides clear differential-trip indication.

Key Advantages

  • Combines residual-current, overload and short-circuit protection in one device.
  • 25 A rated current with B tripping characteristic.
  • 30 mA residual-current sensitivity for additional protection against electric shock.
  • Type F AP-R high-immunity protection suitable for modern electronic loads.
  • 10 kA breaking capacity according to IEC/EN 61009-1.
  • 2-pole configuration with protected neutral.
  • DTI differential-trip indication assists fault identification and maintenance.
  • Direct plug-in connection to the ABB SMISSLINE TP system.

Key Features

  • ABB FS402 series RCBO.
  • 2-pole configuration.
  • 25 A rated current.
  • B tripping characteristic.
  • 30 mA rated residual operating current.
  • Type F AP-R residual-current characteristic.
  • High-immunity design for increased resistance to unwanted tripping.
  • 240 V AC rated operational voltage.
  • 10 kA Icn rated breaking capacity according to IEC/EN 61009-1.
  • 15 kA Icu ultimate short-circuit breaking capacity according to IEC/EN 60947-2.
  • 7.5 kA Ics service short-circuit breaking capacity.
  • 500 V rated insulation voltage.
  • 50 / 60 Hz rated frequency.
  • Three-module plug-in format for the SMISSLINE TP system.

Reliable Protection for SMISSLINE Distribution Systems

RCBOs combine the protective functions of a miniature circuit breaker and a residual-current protective device. The ABB FS402MK-B25/0.03 protects single-phase circuits against overload and short-circuit currents while also detecting residual currents, providing circuit, fault and additional personal protection within one compact device.

The SMISSLINE TP plug-in architecture allows compatible protective devices to connect directly to the socket system, supporting efficient installation, replacement and servicing. The Type F AP-R high-immunity characteristic is well suited to circuits containing electronic equipment that can generate complex residual-current waveforms, while the 30 mA sensitivity provides additional protection against electric shock.

Typical Applications

  • ABB SMISSLINE TP electrical distribution boards.
  • Single-phase final circuits requiring combined RCBO protection.
  • Industrial control and power distribution panels.
  • Commercial and building electrical distribution.
  • Circuits requiring combined overcurrent and 30 mA residual-current protection.
  • Circuits supplying modern electronic, resistive and inductive loads.

Technical Specifications

Product group SMISSLINE Plug-in System
Series FS402
SKU FS402MKB250.03
ABB order code 2CCG001765R0001
EAN / GTIN 7612271522346
Product type Residual current circuit breaker with overcurrent protection (RCBO)
Number of poles 2
Neutral Protected
Rated current 25 A
Tripping characteristic B
Residual-current type Type F, AP-R high immunity
Rated residual operating current 30 mA
Rated operational voltage 240 V AC
Rated insulation voltage 500 V
Rated frequency 50 / 60 Hz
Rated breaking capacity Icn 10 kA according to IEC/EN 61009-1
Ultimate short-circuit breaking capacity Icu 15 kA according to IEC/EN 60947-2
Service short-circuit breaking capacity Ics 7.5 kA
Current limiting class 3
Protection rating IP20
Operating ambient temperature -25 to +60 °C
Flexible conductor capacity 0.75–25 mm²
Width 3 modular spacings
Weight 0.312 kg
Trip indication DTI differential trip indicator
Mounting system SMISSLINE TP plug-in system

Frequently Asked Questions

What is the ABB FS402MKB250.03 used for?

The ABB FS402MKB250.03 is a 2-pole RCBO designed to provide combined overload, short-circuit and residual-current protection for compatible ABB SMISSLINE TP electrical distribution circuits.

What is the current rating of the FS402MK-B25/0.03?

The FS402MK-B25/0.03 has a rated current of 25 A and uses a B tripping characteristic.

What residual-current sensitivity does this RCBO provide?

The FS402MK-B25/0.03 has a rated residual operating current of 30 mA and uses a Type F AP-R high-immunity residual-current characteristic.

What is the breaking capacity of the ABB FS402MK-B25/0.03?

The FS402MK-B25/0.03 has a rated short-circuit breaking capacity Icn of 10 kA according to IEC/EN 61009-1.

Which distribution system is the FS402MK-B25/0.03 designed for?

The RCBO is designed for the ABB SMISSLINE TP plug-in system, allowing direct connection to the compatible socket system for efficient installation and servicing.

Trusted ABB Protection for Electrical Distribution

ABB SMISSLINE RCBOs combine comprehensive circuit protection with efficient plug-in installation, high-immunity residual-current protection and clear fault indication for modern electrical distribution systems.