2CCG001763R0001 ABB FS402MK-B20/0.03 RCBO 2P Type F 20 A 30 mA

2CCG001763R0001 ABB FS402MK-B20/0.03 RCBO 2P Type F 20 A 30 mA

ABB FS402MK-B20/0.03 SMISSLINE TP two-pole Type F AP-R RCBO with 20 A rated current, B characteristic, 30 mA residual current sensitivity and 10 kA breaking capacity.

SKU: 2CCG001763R0001Alt SKU: FS402MKB200.03MPN: 2CCG001763R0001
Price
List Price £263.41 ex VAT
Your Price (ex VAT) Save 35%
£171.22 35% OFF
You save £92.19 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £171.22
Trade pricing is personalised to your account

Manufacturer Lead Time

£171.22

Why Choose the ABB FS402MK-B20/0.03 RCBO?

The ABB FS402MK-B20/0.03 is a high-performance two-pole residual current circuit breaker with overcurrent protection (RCBO) designed for the ABB SMISSLINE TP plug-in distribution system. Combining overload, short-circuit and residual current protection in a single compact device, it provides dependable protection and isolation for commercial, industrial and building electrical installations.

As part of the ABB FS402MK Type F RCBO series, this device uses Type F AP-R high-immunity residual current protection to provide an effective balance between electrical safety and continuity of service. The FS402 design has both poles thermally and magnetically protected, making it suitable for IT network applications, while the DTI earth fault indicator allows differential trips to be identified quickly.

The FS402MK-B20/0.03 features a 20 A rated current, B tripping characteristic, 30 mA rated residual operating current and 10 kA rated breaking capacity according to IEC/EN 61009-1. Its two-pole construction and SMISSLINE TP plug-in format enable efficient installation in compatible ABB electrical distribution systems.

Key Advantages

  • Combines overcurrent and residual current protection in one compact device.
  • 20 A rated current with B tripping characteristic.
  • 30 mA Type F AP-R residual current protection for modern electrical loads.
  • High-immunity design helps improve resistance to unwanted tripping.
  • 10 kA rated breaking capacity according to IEC/EN 61009-1.
  • Both poles are thermally and magnetically protected for use on IT networks.
  • DTI earth fault indicator assists with rapid identification of differential trips.
  • Plug-in design enables efficient integration with the ABB SMISSLINE TP system.

Key Features

  • ABB SMISSLINE TP FS402MK series.
  • Two-pole RCBO configuration.
  • 20 A rated current.
  • B tripping characteristic.
  • 30 mA rated residual operating current.
  • Type F AP-R high-immunity residual current characteristic.
  • 10 kA Icn breaking capacity according to IEC/EN 61009-1.
  • 15 kA ultimate short-circuit capacity according to IEC/EN 60947-2.
  • 7.5 kA service short-circuit capacity according to IEC/EN 60947-2.
  • Integrated DTI earth fault indicator.
  • Contact position indicator for clear identification of contact status.
  • Compact three-module SMISSLINE TP plug-in format.

Reliable Circuit Protection for SMISSLINE TP Systems

RCBOs combine overcurrent and residual current protection within a single device, protecting connected circuits against overloads, short circuits and earth fault currents. This integrated approach supports compact distribution-board design while providing dedicated protection and isolation for individual electrical circuits.

The ABB FS402MK series is designed for the SMISSLINE TP plug-in system and uses Type F AP-R high-immunity residual current technology to improve continuity of service in installations containing modern electronic loads. Both poles of the FS402 are thermally and magnetically protected, allowing the device to be used in IT network applications as well as compatible conventional distribution systems.

Typical Applications

  • ABB SMISSLINE TP electrical distribution systems.
  • Commercial and industrial distribution boards.
  • IT network circuit protection.
  • Circuits supplying resistive and inductive loads.
  • Circuits incorporating modern electronic equipment.
  • Industrial automation and control installations.
  • Building services and electrical infrastructure.

Technical Specifications

Product group SMISSLINE Plug-in System
Series FS402MK
ABB order code 2CCG001763R0001
EAN / GTIN 7612271522322
Product type Residual current circuit breaker with overcurrent protection (RCBO)
Number of poles 2
Protected poles 2
Rated current 20 A
Tripping characteristic B
Residual current type Type F, AP-R high immunity
Rated residual operating current 30 mA
Rated operational voltage 240 / 415 V AC
Rated insulation voltage 500 V
Rated impulse withstand voltage 4 kV
Rated frequency 50 / 60 Hz
Rated breaking capacity Icn 10 kA according to IEC/EN 61009-1
Rated ultimate short-circuit capacity Icu 15 kA according to IEC/EN 60947-2
Rated service short-circuit capacity Ics 7.5 kA according to IEC/EN 60947-2
Energy limiting class 3
Overvoltage category III
Pollution degree 2
Protection rating IP20
Power loss 5.9 W
Width 3 modules
Installation depth 78 mm
Weight approx. 0.312 kg
Mounting system ABB SMISSLINE TP plug-in system
Standards IEC/EN 61009-1, IEC/EN 61009-2-1 and IEC/EN 62423

Frequently Asked Questions

What is the ABB FS402MK-B20/0.03 used for?

The ABB FS402MK-B20/0.03 provides combined overload, short-circuit and residual current protection for circuits installed within compatible ABB SMISSLINE TP distribution systems.

What is the rated current of the FS402MK-B20/0.03?

The RCBO has a rated current of 20 A and uses a B tripping characteristic.

What residual current protection does this RCBO provide?

The FS402MK-B20/0.03 provides Type F AP-R high-immunity residual current protection with a rated residual operating current of 30 mA.

What is the breaking capacity of the ABB FS402MK-B20/0.03?

The device has a rated breaking capacity of 10 kA according to IEC/EN 61009-1, with a rated ultimate short-circuit capacity of 15 kA according to IEC/EN 60947-2.

Can the FS402MK-B20/0.03 be used on IT networks?

Yes. The FS402 design has both poles thermally and magnetically protected, and ABB specifies the series for use on IT networks.

Trusted ABB Circuit Protection

ABB SMISSLINE TP protective devices provide integrated circuit protection in a modular plug-in platform designed for efficient installation, dependable operation and flexible electrical distribution in commercial and industrial applications.