2CCG001761R0001 ABB FS402MKB100.03 FS402MK-B10/0.03 RCBO 2P Type F 10 A 30 mA

2CCG001761R0001 ABB FS402MKB100.03 FS402MK-B10/0.03 RCBO 2P Type F 10 A 30 mA

ABB FS402MKB100.03 FS402MK-B10/0.03 is a 2-pole Type F high-immunity 10 A B-curve 30 mA RCBO with 10 kA breaking capacity and protected poles for ABB SMISSLINE TP and IT network applications.

SKU: 2CCG001761R0001Alt SKU: FS402MKB100.03MPN: 2CCG001761R0001
Price
List Price £263.41 ex VAT
Your Price (ex VAT) Save 35%
£171.22 35% OFF
You save £92.19 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £171.22
Trade pricing is personalised to your account

Manufacturer Lead Time

£171.22

Why Choose the ABB FS402MKB100.03 RCBO?

The ABB FS402MKB100.03, type designation FS402MK-B10/0.03, is a 2-pole residual current circuit breaker with overcurrent protection (RCBO) designed for the ABB SMISSLINE TP plug-in system. It combines overload, short-circuit and residual-current protection in a compact protective device for electrical distribution circuits, with both poles thermally and magnetically protected for use in IT networks.

This FS402MK RCBO has a 10 A rated current, B tripping characteristic and 30 mA rated residual operating current. Its Type F high-immunity residual-current characteristic provides increased resistance to unwanted tripping and is suitable for modern loads incorporating electronic equipment.

With a 10 kA rated short-circuit breaking capacity according to IEC/EN 61009-1, the FS402MK-B10/0.03 provides dependable combined circuit protection. The integrated DTI differential trip indicator helps identify earth-fault tripping quickly, while the SMISSLINE TP plug-in format supports efficient installation, replacement and maintenance.

Key Advantages

  • Combines residual-current, overload and short-circuit protection in one device.
  • 10 A rated current with B tripping characteristic.
  • 30 mA residual-current sensitivity for additional protection against electric shock.
  • Type F high-immunity protection for improved continuity of service with modern electronic loads.
  • Both poles are thermally and magnetically protected, making the FS402 suitable for IT networks.
  • 10 kA breaking capacity according to IEC/EN 61009-1.
  • Integrated DTI earth-fault trip indication assists troubleshooting.
  • Plug-in construction for the ABB SMISSLINE TP system.

Key Features

  • ABB FS402MK series RCBO.
  • 2-pole configuration.
  • Both poles thermally and magnetically protected.
  • 10 A rated current.
  • B tripping characteristic.
  • 30 mA rated residual operating current.
  • Type F residual-current characteristic.
  • High-immunity design for resistance to unwanted tripping.
  • 10 kA Icn rated breaking capacity according to IEC/EN 61009-1.
  • 25 kA Icu ultimate short-circuit breaking capacity according to IEC/EN 60947-2.
  • DTI differential trip indicator for immediate identification of earth-fault tripping.
  • Contact Position Indicator (CPI) for clear contact-status indication.
  • Plug-in format for the SMISSLINE TP system.

Reliable Protection for SMISSLINE and IT Network Applications

RCBOs combine the functions of a miniature circuit breaker and a residual-current protective device. The ABB FS402MK-B10/0.03 protects connected circuits against overload and short-circuit currents while also detecting residual currents, providing coordinated protection within a single compact device.

The FS402 configuration has thermal and magnetic protection on both poles, making it suitable for IT network applications. Its Type F high-immunity characteristic offers an effective balance between safety and continuity of service, while the SMISSLINE TP plug-in architecture simplifies installation and servicing by allowing compatible protective devices to connect directly to the socket system.

Typical Applications

  • ABB SMISSLINE TP electrical distribution boards.
  • IT electrical distribution networks.
  • Industrial control and power distribution panels.
  • Commercial and infrastructure electrical distribution.
  • Circuits requiring combined overcurrent and 30 mA residual-current protection.
  • Circuits incorporating modern electronic, resistive and inductive loads.

Technical Specifications

Product group SMISSLINE Plug-in System
Series FS402MK
SKU FS402MKB100.03
ABB order code 2CCG001761R0001
EAN / GTIN 7612271522308
Product type Residual current circuit breaker with overcurrent protection (RCBO)
Number of poles 2
Protected poles 2
Rated current 10 A
Tripping characteristic B
Residual-current type Type F
Rated residual operating current 30 mA
Rated breaking capacity Icn 10 kA according to IEC/EN 61009-1
Ultimate short-circuit breaking capacity Icu 25 kA according to IEC/EN 60947-2
Trip indication DTI differential trip indicator
Contact indication Contact Position Indicator (CPI)
Application Suitable for IT networks
Weight 0.312 kg
Mounting system SMISSLINE TP plug-in system

Frequently Asked Questions

What is the ABB FS402MKB100.03 used for?

The ABB FS402MKB100.03 is a 2-pole RCBO providing combined overload, short-circuit and residual-current protection in compatible ABB SMISSLINE TP systems, with both poles protected for use in IT networks.

What is the current rating of the FS402MK-B10/0.03?

The RCBO has a rated current of 10 A and uses a B tripping characteristic.

What residual-current sensitivity does this RCBO provide?

The FS402MK-B10/0.03 has a rated residual operating current of 30 mA and uses a Type F high-immunity residual-current characteristic.

What is the breaking capacity of the ABB FS402MK-B10/0.03?

The FS402MK-B10/0.03 has a rated short-circuit breaking capacity Icn of 10 kA according to IEC/EN 61009-1.

Why is the ABB FS402MK suitable for IT networks?

The FS402 has thermal and magnetic overcurrent protection on both poles, enabling its use in IT network applications while also providing residual-current protection.

Trusted ABB Protection for Electrical Distribution

ABB SMISSLINE RCBOs combine comprehensive circuit protection with plug-in installation, clear fault indication and high operational continuity for modern electrical distribution systems.