2CCG001752R0001 ABB FS403MKC320.03 FS403MK-C32/0.03 RCBO 3P+N Type F 32 A 30 mA

2CCG001752R0001 ABB FS403MKC320.03 FS403MK-C32/0.03 RCBO 3P+N Type F 32 A 30 mA

ABB FS403MKC320.03 FS403MK-C32/0.03 is a 3P+N Type F 32 A C-curve 30 mA short-time delayed RCBO with 10 kA breaking capacity for the SMISSLINE TP plug-in system.

SKU: 2CCG001752R0001Alt SKU: FS403MKC320.03MPN: 2CCG001752R0001
Price
List Price £516.63 ex VAT
Your Price (ex VAT) Save 35%
£335.81 35% OFF
You save £180.82 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £335.81
Trade pricing is personalised to your account

Manufacturer Lead Time

£335.81

Why Choose the ABB FS403MKC320.03 RCBO?

The ABB FS403MKC320.03, type designation FS403MK-C32/0.03, is a high-performance 3P+N residual current circuit breaker with overcurrent protection (RCBO) designed for the ABB SMISSLINE TP plug-in system. It combines overload, short-circuit and residual-current protection in a single four-pole protective device for industrial and commercial electrical distribution.

This FS403MK series RCBO has a 32 A rated current, C tripping characteristic and 30 mA rated residual operating current. Its Type F residual-current characteristic with short-time delayed operation is designed for circuits incorporating modern electronic equipment and provides additional protection against electric shock while helping resist unwanted tripping caused by transient leakage currents.

With a 10 kA rated short-circuit breaking capacity according to EN 61009-1, the FS403MK-C32/0.03 provides dependable protection for three-phase circuits. Its plug-in construction enables direct connection to the SMISSLINE TP socket system, helping simplify installation, replacement and maintenance within compatible electrical distribution assemblies.

Key Advantages

  • Combines residual-current, overload and short-circuit protection in one device.
  • 32 A rated current with C tripping characteristic.
  • 30 mA residual-current sensitivity for additional protection against electric shock.
  • Type F residual-current characteristic suitable for circuits incorporating electronic loads.
  • Short-time delayed operation helps improve resistance to unwanted tripping.
  • 10 kA breaking capacity according to EN 61009-1.
  • Four-pole configuration with three protected poles plus neutral.
  • Plug-in design for efficient integration with the ABB SMISSLINE TP system.

Key Features

  • ABB FS403MK series RCBO.
  • 32 A rated current.
  • C tripping characteristic.
  • 30 mA rated residual operating current.
  • Type F residual-current characteristic.
  • Short-time delayed protection characteristic.
  • 10 kA Icn rated breaking capacity according to EN 61009-1.
  • 15 kA breaking capacity according to IEC 60947-2.
  • 4 kV rated impulse withstand voltage.
  • 3 kA surge current withstand.
  • Current-limiting class 3.
  • Four-module plug-in format for the SMISSLINE TP system.

Reliable Circuit Protection for SMISSLINE Distribution Systems

RCBOs combine the protective functions of a miniature circuit breaker and a residual-current protective device. The ABB FS403MK-C32/0.03 therefore protects connected circuits against overload and short-circuit currents while also detecting residual currents that can present electric-shock and electrical-fire hazards.

The SMISSLINE TP plug-in architecture allows compatible protective devices to connect directly to the socket system, supporting efficient installation and servicing. The Type F characteristic provides residual-current protection suitable for modern electronic loads, while the short-time delayed response helps improve operational continuity where transient leakage currents could otherwise result in unwanted tripping.

Typical Applications

  • ABB SMISSLINE TP electrical distribution boards.
  • Industrial control and power distribution panels.
  • Commercial building electrical distribution.
  • Three-phase circuits requiring combined overcurrent and residual-current protection.
  • Circuits supplying electronic equipment suitable for Type F residual-current protection.
  • Machinery and industrial automation electrical systems.

Technical Specifications

Product group SMISSLINE Plug-in System
Series FS403MK
SKU FS403MKC320.03
ABB order code 2CCG001752R0001
EAN / GTIN 7612271522216
Product type Residual current circuit breaker with overcurrent protection (RCBO)
Poles 3P+N (4 poles total)
Protected poles 3
Rated current 32 A
Tripping characteristic C
Residual-current type Type F
Rated residual operating current 30 mA
Operating characteristic Short-time delayed
Rated breaking capacity Icn 10 kA according to EN 61009-1
Rated breaking capacity 15 kA according to IEC 60947-2
Rated impulse withstand voltage 4 kV
Current-limiting class 3
Surge current withstand 3 kA
Power loss 12.6 W
Pollution degree 2
Overvoltage category III
Operating ambient temperature -25 to +60 °C
Width 4 modular spacings
Built-in depth 78 mm
Multi-wired conductor connection 0.75–25 mm²
Weight 0.42 kg
Mounting system SMISSLINE TP plug-in system

Frequently Asked Questions

What is the ABB FS403MKC320.03 used for?

The ABB FS403MKC320.03 is a 3P+N RCBO designed to provide combined overload, short-circuit and residual-current protection in compatible ABB SMISSLINE TP distribution systems.

What is the current rating of the FS403MK-C32/0.03?

The RCBO has a rated current of 32 A and uses a C tripping characteristic.

What residual-current protection does this RCBO provide?

The FS403MK-C32/0.03 has a rated residual operating current of 30 mA and uses a Type F residual-current characteristic with short-time delayed operation.

What is the breaking capacity of the ABB FS403MK-C32/0.03?

Its rated short-circuit breaking capacity Icn is 10 kA according to EN 61009-1.

Which distribution system is the FS403MK-C32/0.03 designed for?

It is a plug-in protective device designed for the ABB SMISSLINE TP system, enabling direct connection to the compatible SMISSLINE socket system.

Trusted ABB Protection for Electrical Distribution

ABB SMISSLINE protective devices combine modular plug-in installation with dependable circuit protection, helping panel builders and electrical engineers create efficient, serviceable and robust power distribution systems.