2CCG001751R0001 ABB FS403MKC250.03 FS403MK-C25/0.03 RCBO 3P+N Type F 25 A 30 mA

2CCG001751R0001 ABB FS403MKC250.03 FS403MK-C25/0.03 RCBO 3P+N Type F 25 A 30 mA

ABB FS403MKC250.03 FS403MK-C25/0.03 is a 3P+N Type F 25 A C-curve 30 mA short-time delayed RCBO with 10 kA breaking capacity for the SMISSLINE TP plug-in system.

SKU: 2CCG001751R0001Alt SKU: FS403MKC250.03MPN: 2CCG001751R0001
Price
List Price £504.25 ex VAT
Your Price (ex VAT) Save 35%
£327.76 35% OFF
You save £176.49 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £327.76
Trade pricing is personalised to your account

Manufacturer Lead Time

£327.76

Why Choose the ABB FS403MKC250.03 RCBO?

The ABB FS403MKC250.03, type designation FS403MK-C25/0.03, is a high-performance 3P+N residual current circuit breaker with overcurrent protection (RCBO) designed for the ABB SMISSLINE TP plug-in system. It combines overload, short-circuit and residual-current protection in a single four-pole protective device for industrial and commercial electrical distribution.

This FS403M series RCBO has a 25 A rated current, C tripping characteristic and 30 mA rated residual operating current. Its Type F residual-current characteristic with short-time delay provides protection for circuits containing modern electronic equipment while helping provide reliable operation in demanding installations.

With a 415 V AC rated voltage and a 10 kA rated short-circuit breaking capacity according to EN 61009-1, the FS403MK-C25/0.03 provides dependable protection for three-phase circuits. Its plug-in construction allows direct connection to the SMISSLINE TP socket system, helping simplify installation, replacement and maintenance within compatible distribution assemblies.

Key Advantages

  • Combines residual-current, overload and short-circuit protection in one device.
  • 25 A rated current with C tripping characteristic.
  • 30 mA residual-current sensitivity for additional protection against electric shock.
  • Type F residual-current characteristic suitable for circuits containing electronic loads.
  • Short-time delayed operation helps improve resistance to unwanted tripping.
  • 10 kA breaking capacity according to EN 61009-1.
  • Four-pole 3P+N configuration with three protected poles.
  • Plug-in design for efficient integration with the ABB SMISSLINE TP system.

Key Features

  • ABB FS403M series RCBO.
  • 25 A rated current.
  • C tripping characteristic.
  • 30 mA rated residual operating current.
  • Type F residual-current characteristic.
  • Short-time delayed RCBO design.
  • 415 V AC rated voltage.
  • 10 kA Icn rated breaking capacity according to EN 61009-1.
  • 500 V rated insulation voltage.
  • 4 kV rated impulse withstand voltage.
  • 3 kA surge current capacity.
  • IP20 protection rating.
  • Four-module plug-in format for the SMISSLINE TP system.

Reliable Circuit Protection for SMISSLINE Distribution Systems

RCBOs combine the protective functions of a miniature circuit breaker and a residual-current protective device. The ABB FS403MK-C25/0.03 therefore protects connected circuits against overload and short-circuit currents while also detecting residual currents that can create electric-shock, equipment and electrical-fire hazards.

The SMISSLINE TP plug-in architecture allows compatible protective devices to connect directly to the socket system, reducing conventional wiring requirements and supporting efficient installation and servicing. The Type F characteristic is intended for circuits containing modern electronic loads, while the short-time delayed response helps provide dependable operation where transient leakage currents may otherwise cause unwanted tripping.

Typical Applications

  • ABB SMISSLINE TP electrical distribution boards.
  • Industrial control and power distribution panels.
  • Commercial building electrical distribution.
  • Three-phase circuits requiring combined overcurrent and residual-current protection.
  • Circuits supplying electronic equipment and loads suitable for Type F protection.
  • Machinery and industrial automation electrical systems.

Technical Specifications

Product group SMISSLINE Plug-in System
Series FS403M
SKU FS403MKC250.03
ABB order code 2CCG001751R0001
EAN 7612271522209
Product type Residual current circuit breaker with overcurrent protection (RCBO)
Poles 3P+N (4 poles total)
Protected poles 3
Rated current 25 A
Tripping characteristic C
Residual-current type Type F
Rated residual operating current 30 mA
Operating characteristic Short-time delayed
Rated voltage 415 V AC
Rated insulation voltage 500 V
Rated impulse withstand voltage 4 kV
Rated breaking capacity Icn 10 kA according to EN 61009-1
Rated short-circuit breaking capacity 15 kA according to IEC 60947-2
Frequency 50 / 60 Hz
Current limiting class 3
Surge current capacity 3 kA
Power loss 10.1 W
Protection rating IP20
Pollution degree 2
Overvoltage category III
Operating ambient temperature -25 to +60 °C
Width 4 modular spacings
Built-in depth 91 mm
Multi-wired conductor connection 0.75–25 mm²
Weight 0.42 kg
Mounting system SMISSLINE TP plug-in system

Frequently Asked Questions

What is the ABB FS403MKC250.03 used for?

The ABB FS403MKC250.03 is a 3P+N RCBO designed to provide combined overload, short-circuit and residual-current protection in compatible ABB SMISSLINE TP distribution systems.

What is the current rating of the FS403MK-C25/0.03?

The RCBO has a rated current of 25 A and uses a C tripping characteristic.

What residual-current protection does this RCBO provide?

The FS403MK-C25/0.03 has a rated residual operating current of 30 mA and a Type F residual-current characteristic with short-time delayed operation.

What is the breaking capacity of the ABB FS403MK-C25/0.03?

Its rated short-circuit breaking capacity Icn is 10 kA according to EN 61009-1.

Which distribution system is the FS403MK-C25/0.03 designed for?

It is a plug-in protective device designed for the ABB SMISSLINE TP system, enabling direct connection to the compatible SMISSLINE socket system.

Trusted ABB Protection for Electrical Distribution

ABB SMISSLINE protective devices combine modular plug-in installation with dependable circuit protection, helping panel builders and electrical engineers create efficient, serviceable and robust power distribution systems.