2CCG001748R0001 ABB FS403MKC130.03 FS403MK-C13/0.03 RCBO 3P+N Type F 13 A 30 mA

2CCG001748R0001 ABB FS403MKC130.03 FS403MK-C13/0.03 RCBO 3P+N Type F 13 A 30 mA

ABB FS403MKC130.03 FS403MK-C13/0.03 is a 3P+N Type F 13 A C-curve 30 mA RCBO with 10 kA breaking capacity for the SMISSLINE Plug-in System.

SKU: 2CCG001748R0001Alt SKU: FS403MKC130.03MPN: 2CCG001748R0001
Price
List Price £464.01 ex VAT
Your Price (ex VAT) Save 35%
£301.61 35% OFF
You save £162.40 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £301.61
Trade pricing is personalised to your account

Manufacturer Lead Time

£301.61

Why Choose the ABB FS403MKC130.03 RCBO?

The ABB FS403MKC130.03, type designation FS403MK-C13/0.03, is a pluggable 3P+N residual current circuit breaker with overcurrent protection (RCBO) for the ABB SMISSLINE Plug-in System. It combines overload, short-circuit and residual-current protection in a single compact protective device for industrial and commercial electrical distribution.

This FS403M-K series RCBO has a 13 A rated current, C tripping characteristic and 30 mA residual operating current. Its Type F residual-current characteristic is designed to detect sinusoidal AC and pulsating DC residual currents while providing protection suitable for loads incorporating modern electronic equipment.

With a 415 V AC rated operational voltage and 10 kA rated short-circuit breaking capacity according to EN 61009-1, the FS403MK-C13/0.03 provides dependable circuit protection within SMISSLINE TP distribution systems. Its plug-in construction enables direct connection to the SMISSLINE socket system, supporting efficient installation and maintenance.

Key Advantages

  • Combines residual-current, overload and short-circuit protection in one device.
  • 13 A rated current with C tripping characteristic.
  • 30 mA residual operating current for additional protection against electric shock.
  • Type F residual-current protection for modern electrical and electronic loads.
  • 10 kA breaking capacity according to EN 61009-1.
  • Pluggable 3P+N design for the ABB SMISSLINE TP system.
  • Direct plug-in connection helps simplify installation, replacement and distribution-board maintenance.

Key Features

  • ABB FS403M-K series RCBO.
  • 3P+N configuration with three protected poles.
  • 13 A rated current.
  • C tripping characteristic.
  • 30 mA rated residual operating current.
  • Type F residual-current characteristic.
  • 415 V AC rated operational voltage.
  • 10 kA rated breaking capacity according to EN 61009-1.
  • 500 V rated insulation voltage.
  • 4 kV rated impulse withstand voltage.
  • IP20 protection rating.
  • Four-module plug-in format for the SMISSLINE TP system.

Reliable Circuit Protection for SMISSLINE Distribution Systems

RCBOs combine the functions of a miniature circuit breaker and residual-current protective device. The ABB FS403MK-C13/0.03 therefore protects connected circuits against overload and short-circuit currents while also responding to residual currents that can present electric-shock and electrical-installation hazards.

The SMISSLINE TP plug-in architecture allows compatible protective devices to connect directly to the socket system, reducing conventional wiring requirements and supporting efficient installation and servicing. The Type F residual-current characteristic makes this RCBO particularly suitable for circuits supplying equipment containing electronic components that can produce mixed-frequency residual currents.

Typical Applications

  • ABB SMISSLINE TP electrical distribution boards.
  • Industrial control and distribution panels.
  • Commercial building electrical distribution.
  • Three-phase circuits requiring combined overcurrent and residual-current protection.
  • Circuits supplying electronic and variable-frequency loads suitable for Type F protection.
  • Machinery and automation electrical distribution systems.

Technical Specifications

Product group SMISSLINE Plug-in System
Series FS403M-K
SKU FS403MKC130.03
ABB order code 2CCG001748R0001
Product type Residual current circuit breaker with overcurrent protection (RCBO)
Poles 3P+N (4 poles total)
Protected poles 3
Rated current 13 A
Tripping characteristic C
Residual-current type Type F
Rated residual operating current 30 mA
Rated operational voltage 415 V AC
Rated insulation voltage 500 V
Rated impulse withstand voltage 4 kV
Rated breaking capacity Icn 10 kA according to EN 61009-1
Frequency 50 / 60 Hz
Current limiting class 3
Surge current capacity 3 kA
Protection rating IP20
Pollution degree 2
Overvoltage category III
Operating ambient temperature -25 to +60 °C
Width 4 modular spacings
Built-in depth 91 mm
Multi-wired conductor connection 0.75–25 mm²
Weight 0.42 kg
EAN 7612271522179

Frequently Asked Questions

What is the ABB FS403MKC130.03 used for?

The ABB FS403MKC130.03 is a 3P+N RCBO used to provide combined overload, short-circuit and residual-current protection in compatible ABB SMISSLINE plug-in distribution systems.

What is the current rating of the FS403MK-C13/0.03?

The RCBO has a rated current of 13 A and uses a C tripping characteristic.

What residual-current sensitivity does this RCBO provide?

The FS403MK-C13/0.03 has a rated residual operating current of 30 mA and uses a Type F residual-current characteristic.

What is the breaking capacity of the ABB FS403MK-C13/0.03?

Its rated short-circuit breaking capacity Icn is 10 kA according to EN 61009-1.

Which distribution system is the FS403MK-C13/0.03 designed for?

It is a plug-in protective device designed for the ABB SMISSLINE TP system, enabling direct connection to the compatible SMISSLINE socket system.

Trusted ABB Protection for Electrical Distribution

ABB SMISSLINE protective devices combine modular plug-in installation with dependable circuit protection, helping panel builders and electrical engineers create efficient, serviceable and robust power distribution systems.