2CCG001745R0001 ABB FS403MK-B32/0.03 RCBO 3P+N Type F 32 A 30 mA

2CCG001745R0001 ABB FS403MK-B32/0.03 RCBO 3P+N Type F 32 A 30 mA

ABB FS403MK-B32/0.03 is a SMISSLINE TP 3P+N Type F short-time-delayed RCBO with a 32 A B-curve rating, 30 mA residual-current sensitivity, 415 V AC rated voltage and 10 kA breaking capacity.

SKU: 2CCG001745R0001Alt SKU: FS403MKB320.03MPN: 2CCG001745R0001
Price
List Price £464.03 ex VAT
Your Price (ex VAT) Save 35%
£301.62 35% OFF
You save £162.41 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £301.62
Trade pricing is personalised to your account

Manufacturer Lead Time

£301.62

Why Choose the ABB FS403MK-B32/0.03 RCBO?

The ABB FS403MK-B32/0.03 is a pluggable 3P+N residual current circuit breaker with overcurrent protection (RCBO) designed for the ABB SMISSLINE TP distribution system. Combining overload, short-circuit and residual-current protection in one four-pole device, it provides integrated protection for three-phase circuits with neutral in residential, commercial and industrial electrical installations.

This FS403MK model provides Type F residual-current protection with a short-time-delayed APR characteristic, helping improve resistance to unwanted tripping while maintaining dependable residual-current protection. Its 30 mA residual-current sensitivity provides additional protection against electric shock, while DTI indication helps identify operation caused by a residual-current fault.

With a rated current of 32 A, a B tripping characteristic and a rated residual operating current of 30 mA, the FS403MK-B32/0.03 provides a rated short-circuit breaking capacity of 10 kA according to EN 61009-1. Its SMISSLINE TP plug-in construction enables efficient integration, replacement and maintenance within compatible distribution systems.

Key Advantages

  • Combines residual-current, overload and short-circuit protection in one device.
  • 3P+N four-pole configuration for three-phase circuits with neutral.
  • 32 A rated current with B-curve overcurrent characteristic.
  • 30 mA residual-current sensitivity for additional protection against electric shock.
  • Type F residual-current protection with short-time-delayed APR characteristics for improved resistance to unwanted tripping.
  • 10 kA rated breaking capacity according to EN 61009-1.
  • Direct plug-in installation into the ABB SMISSLINE TP system.

Key Features

  • ABB FS403MK RCBO series.
  • 3P+N configuration with four poles and three protected poles.
  • 32 A rated current.
  • B tripping characteristic.
  • 30 mA rated residual operating current.
  • Type F residual-current characteristic.
  • Short-time-delayed APR design for enhanced resistance to unwanted tripping.
  • 415 V AC rated voltage at 50/60 Hz.
  • 10 kA rated short-circuit breaking capacity according to EN 61009-1.
  • 15 kA breaking capacity according to IEC 60947-2.
  • Integrated DTI residual-current trip indication.
  • Four-module SMISSLINE TP plug-in format with 78 mm installation depth.

Type F RCBO Protection for SMISSLINE TP

An RCBO combines the protective functions of a miniature circuit breaker and a residual-current protective device in one unit. The ABB FS403MK-B32/0.03 therefore protects circuits against overload and short-circuit currents while monitoring for residual currents associated with insulation faults, earth leakage and other electrical faults.

Its Type F residual-current characteristic is suited to applications containing modern electronic equipment and loads capable of producing mixed-frequency residual currents. Combined with its short-time-delayed APR characteristic, 30 mA sensitivity, 10 kA rated breaking capacity and SMISSLINE TP plug-in construction, the FS403MK-B32/0.03 provides robust protection with enhanced resistance to unwanted tripping.

Typical Applications

  • ABB SMISSLINE TP electrical distribution systems.
  • Three-phase circuits with neutral.
  • Commercial and industrial electrical distribution.
  • Circuits supplying electronic equipment and frequency-controlled loads.
  • Applications requiring enhanced resistance to unwanted residual-current tripping.
  • Circuits requiring 32 A B-curve overcurrent protection.
  • Applications requiring combined overload, short-circuit and 30 mA Type F residual-current protection.

Technical Specifications

Product group SMISSLINE Plug-in System
Series FS403MK
ABB order code 2CCG001745R0001
EAN / GTIN 7612271522148
Product type Residual current circuit breaker with overcurrent protection (RCBO)
Poles 3P+N
Total number of poles 4
Number of protected poles 3
Rated current 32 A
Tripping characteristic B
Residual-current type Type F
Residual-current characteristic Short-time delayed (APR)
Rated residual operating current 30 mA
Rated voltage 415 V AC
Rated insulation voltage 500 V
Rated impulse withstand voltage 4 kV
Rated frequency 50/60 Hz
Rated breaking capacity Icn 10 kA according to EN 61009-1
Breaking capacity 15 kA according to IEC 60947-2
Surge-current resistance 3 kA
Current limiting class 3
Overvoltage category III
Pollution degree 2
Number of modules 4
Installation depth 78 mm
Power loss 12.6 W
Connectable conductor cross-section, multi-wired 0.75–25 mm²
Mounting type SMISSLINE TP plug-in
Protection rating IP20
Product standard IEC/EN 61009-1
Weight approx. 0.42 kg

Frequently Asked Questions

What is the ABB FS403MK-B32/0.03 used for?

It is a 3P+N RCBO designed to provide overload, short-circuit and 30 mA Type F residual-current protection for circuits within ABB SMISSLINE TP distribution systems.

What is the rated current and tripping characteristic of the FS403MK-B32/0.03?

The RCBO has a rated current of 32 A and uses a B tripping characteristic.

What residual-current protection does this RCBO provide?

The FS403MK-B32/0.03 provides Type F residual-current protection with 30 mA sensitivity and a short-time-delayed APR characteristic that helps improve resistance to unwanted tripping.

What is the breaking capacity of the ABB FS403MK-B32/0.03?

The device has a rated short-circuit breaking capacity of 10 kA according to EN 61009-1 and a breaking capacity of 15 kA according to IEC 60947-2.

How is the FS403MK-B32/0.03 installed?

The RCBO is designed for plug-in installation in the ABB SMISSLINE TP system, enabling efficient integration, replacement and maintenance within compatible electrical distribution assemblies.

Trusted ABB Type F Circuit Protection

ABB SMISSLINE TP RCBOs combine modular plug-in installation with integrated overcurrent and residual-current protection, while Type F short-time-delayed variants provide enhanced protection and resistance to unwanted tripping for circuits incorporating modern electronic and frequency-dependent loads.