ABB FS403MK-B13/0.03 is a SMISSLINE TP 3P+N Type F short-time-delayed RCBO with a 13 A B-curve rating, 30 mA residual-current sensitivity, 415 V AC operational voltage and 10 kA breaking capacity.
£271.45
The ABB FS403MK-B13/0.03 is a pluggable 3P+N residual current circuit breaker with overcurrent protection (RCBO) designed for the ABB SMISSLINE TP distribution system. Combining overload, short-circuit and residual-current protection in one four-pole device, it provides integrated protection for three-phase circuits with neutral in residential, commercial and industrial electrical installations.
This FS403MK model provides Type F residual-current protection with a short-time-delayed characteristic designed to improve resistance to unwanted tripping while maintaining protection against relevant residual currents. Its 30 mA residual-current sensitivity provides additional protection against electric shock, while DTI indication helps identify operation caused by a residual-current fault.
With a rated current of 13 A, a B tripping characteristic and a rated residual operating current of 30 mA, the FS403MK-B13/0.03 provides a rated short-circuit breaking capacity of 10 kA according to EN 61009-1. Its SMISSLINE TP plug-in construction enables efficient integration, replacement and maintenance within compatible distribution systems.
An RCBO combines the protective functions of a miniature circuit breaker and a residual-current protective device in one unit. The ABB FS403MK-B13/0.03 therefore protects circuits against overload and short-circuit currents while monitoring for residual currents associated with insulation faults, earth leakage and other electrical faults.
Its Type F residual-current characteristic is particularly suited to circuits containing modern electronic equipment and loads that can produce mixed-frequency residual currents. The short-time-delayed characteristic increases resistance to unwanted tripping, while 30 mA sensitivity, a 10 kA breaking capacity and SMISSLINE TP plug-in construction provide a compact protection solution for compatible distribution systems.
| Product group | SMISSLINE Plug-in System |
|---|---|
| Series | FS403MK |
| ABB order code | 2CCG001741R0001 |
| EAN / GTIN | 7612271522100 |
| Product type | Residual current circuit breaker with overcurrent protection (RCBO) |
| Poles | 3P+N |
| Total number of poles | 4 |
| Number of protected poles | 3 |
| Rated current | 13 A |
| Tripping characteristic | B |
| Residual-current type | Type F |
| Residual-current characteristic | Short-time delayed |
| Rated residual operating current | 30 mA |
| Rated operational voltage | 415 V AC |
| Rated insulation voltage | 500 V |
| Rated impulse withstand voltage | 4 kV |
| Rated frequency | 50/60 Hz |
| Rated breaking capacity Icn | 10 kA according to EN 61009-1 |
| Breaking capacity | 25 kA according to IEC 60947-2 |
| Surge-current resistance | 3 kA |
| Current limiting class | 3 |
| Overvoltage category | III |
| Pollution degree | 2 |
| Number of modules | 4 |
| Installation depth | 78 mm |
| Power loss | 5.4 W |
| Connectable conductor cross-section, multi-wired | 0.75–25 mm² |
| Mounting type | SMISSLINE TP plug-in |
| Protection rating | IP20 |
| Operating ambient temperature | -25 to +60 °C |
| Product standard | IEC/EN 61009-1 |
| Weight | approx. 0.42 kg |
It is a 3P+N RCBO designed to provide overload, short-circuit and 30 mA Type F residual-current protection for circuits within ABB SMISSLINE TP distribution systems.
The RCBO has a rated current of 13 A and uses a B tripping characteristic.
The FS403MK-B13/0.03 provides Type F residual-current protection with 30 mA sensitivity and a short-time-delayed characteristic that improves resistance to unwanted tripping.
The device has a rated short-circuit breaking capacity of 10 kA according to EN 61009-1 and a breaking capacity of 25 kA according to IEC 60947-2.
The RCBO is designed for plug-in installation in the ABB SMISSLINE TP system, enabling efficient integration, replacement and maintenance within compatible electrical distribution assemblies.
ABB SMISSLINE TP RCBOs combine modular plug-in installation with integrated overcurrent and residual-current protection, while Type F variants provide enhanced protection and continuity of service for circuits incorporating modern electronic and frequency-dependent loads.