2CCG001736R0001 ABB FS403M-C20/0.1 RCBO 3P+N Type A 20 A 100 mA

2CCG001736R0001 ABB FS403M-C20/0.1 RCBO 3P+N Type A 20 A 100 mA

ABB FS403M-C20/0.1 is a 3P+N Type A 20 A C-curve RCBO with 100 mA residual-current protection, 10 kA breaking capacity and DTI earth-fault indication for the SMISSLINE TP plug-in system.

SKU: 2CCG001736R0001Alt SKU: FS403MC200.1MPN: 2CCG001736R0001
Price
List Price £375.01 ex VAT
Your Price (ex VAT) Save 35%
£243.76 35% OFF
You save £131.25 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £243.76
Trade pricing is personalised to your account

Manufacturer Lead Time

£243.76

Why Choose the ABB FS403M-C20/0.1 RCBO?

The ABB FS403M-C20/0.1 is a 3P+N Type A residual current circuit breaker with overcurrent protection (RCBO) designed for the ABB SMISSLINE TP plug-in system. It combines overload, short-circuit and residual-current protection in one four-pole device, providing coordinated protection for three-phase circuits with neutral in residential, commercial and industrial electrical installations.

This FS403M model has a 20 A rated current, C tripping characteristic and 100 mA rated residual operating current. Its Type A residual-current characteristic responds to sinusoidal alternating and pulsating DC residual currents, providing earth-fault protection for circuits where this residual-current type and sensitivity are specified.

With a 10 kA rated short-circuit breaking capacity according to EN 61009-1, the FS403M-C20/0.1 provides robust protection for three-phase distribution applications. Integrated DTI earth-fault indication assists fault identification, while direct connection to the SMISSLINE TP plug-in system supports efficient installation, servicing and circuit replacement.

Key Advantages

  • Combines overload, short-circuit and residual-current protection in one RCBO.
  • 3P+N configuration for three-phase circuits with neutral.
  • 20 A C-curve rating for suitable final and distribution circuits.
  • Type A residual-current protection responds to sinusoidal AC and pulsating DC residual currents.
  • 100 mA residual-current sensitivity provides earth-fault protection for suitable applications.
  • 10 kA rated short-circuit breaking capacity according to EN 61009-1.
  • Integrated DTI earth-fault indication supports efficient fault identification.
  • Direct integration with the ABB SMISSLINE TP plug-in system supports efficient installation and maintenance.

Key Features

  • ABB FS403M RCBO series.
  • 3P+N / four-pole configuration.
  • Three protected poles.
  • 20 A rated current.
  • C tripping characteristic.
  • 100 mA rated residual operating current.
  • Type A residual-current detection.
  • 10 kA rated short-circuit breaking capacity according to EN 61009-1.
  • Current-limiting class 3.
  • 3 kA surge-current withstand.
  • Integrated DTI differential-trip indication.
  • Direct plug-in connection to the SMISSLINE TP system.
  • Compact four-module format.

Reliable Three-Phase Circuit and Earth-Fault Protection

The ABB FS403M-C20/0.1 combines miniature circuit-breaker and residual-current functions within one device. It protects three-phase circuits with neutral against overload and short-circuit currents while monitoring for residual currents caused by insulation faults or unintended current flow to earth.

Its Type A characteristic responds to sinusoidal alternating and pulsating DC residual currents, while the 100 mA residual-current threshold provides earth-fault protection for suitable applications. Integration with ABB's SMISSLINE TP plug-in architecture also supports efficient distribution-board assembly, servicing and circuit replacement.

Typical Applications

  • Three-phase circuits with neutral in SMISSLINE TP distribution systems.
  • Residential electrical distribution.
  • Commercial building distribution boards.
  • Industrial electrical distribution and auxiliary circuits.
  • Circuits requiring combined overcurrent and Type A residual-current protection.
  • Installations requiring 100 mA earth-fault protection.

Technical Specifications

Series FS403M / SMISSLINE TP
ABB order code 2CCG001736R0001
EAN / GTIN 7612271522056
Product type Residual current circuit breaker with overcurrent protection (RCBO)
Poles 3P+N / 4 poles
Protected poles 3
Rated current 20 A
Tripping characteristic C
Residual-current type Type A
Rated residual operating current 100 mA
Rated short-circuit breaking capacity (Icn) 10 kA according to EN 61009-1
Product standard IEC/EN 61009
Current-limiting class 3
Surge-current withstand 3 kA
Trip indication DTI earth-fault indication
Mounting system SMISSLINE TP plug-in system
Module width 4 modules
Installation depth 78 mm
Overvoltage category III
Pollution degree 2
Power loss 7.5 W
Weight approx. 0.420 kg

Frequently Asked Questions

What is the ABB FS403M-C20/0.1 used for?

It is a 3P+N RCBO designed to protect three-phase circuits with neutral against overload, short-circuit and residual-current faults within ABB SMISSLINE TP distribution systems.

What is the current rating of the FS403M-C20/0.1?

The FS403M-C20/0.1 has a rated current of 20 A with a C tripping characteristic.

What residual-current sensitivity does this RCBO provide?

The FS403M-C20/0.1 has a rated residual operating current of 100 mA and uses Type A residual-current detection.

What is the breaking capacity of the FS403M-C20/0.1?

The FS403M-C20/0.1 has a rated short-circuit breaking capacity of 10 kA according to EN 61009-1.

What does the DTI feature do?

The integrated DTI earth-fault indication helps identify residual-current operation, supporting faster fault diagnosis and maintenance.

Trusted ABB Protection for SMISSLINE TP Systems

ABB FS403M RCBOs combine three-phase overcurrent and Type A residual-current protection with fault indication and SMISSLINE TP plug-in installation for dependable protection of residential, commercial and industrial electrical circuits.