Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
ABB FS403M-B16/0.03 is a 3P+N Type A 16 A B-curve RCBO with 30 mA residual-current protection, 10 kA breaking capacity and DTI earth-fault indication for the SMISSLINE TP plug-in system.
£245.15
The ABB FS403M-B16/0.03 is a compact and reliable 3P+N Type A residual current circuit breaker with overcurrent protection (RCBO) designed for the ABB SMISSLINE TP plug-in system. It combines overload, short-circuit and residual-current protection in a single four-pole device, providing comprehensive protection for three-phase circuits with neutral in residential, commercial and industrial electrical distribution systems.
This FS403M model has a 16 A rated current, B tripping characteristic and 30 mA rated residual operating current. Its Type A residual-current detection responds to sinusoidal alternating and pulsating DC residual currents, while the 30 mA sensitivity provides additional protection against direct contact as well as protection against indirect contact.
With a rated voltage of 415 V AC and a 10 kA rated short-circuit breaking capacity according to EN 61009-1, the FS403M-B16/0.03 provides robust protection for modern three-phase installations. Its integrated DTI earth-fault indication assists fault diagnosis, while the SMISSLINE TP plug-in format supports efficient installation and maintenance.
An RCBO combines miniature circuit-breaker and residual-current protection within one device. The ABB FS403M-B16/0.03 therefore protects three-phase circuits with neutral against overload and short-circuit currents while monitoring for residual currents caused by insulation faults or current flowing to earth.
Its Type A residual-current characteristic provides protection against sinusoidal alternating and pulsating DC residual currents, while the 30 mA sensitivity provides additional protection against direct contact in appropriate installations. Integration with ABB's SMISSLINE TP plug-in architecture also enables efficient distribution-board assembly, maintenance and circuit replacement.
| Series | FS403M / SMISSLINE TP |
|---|---|
| ABB order code | 2CCG001714R0001 |
| EAN / GTIN | 7612271521837 |
| Product type | Residual current circuit breaker with overcurrent protection (RCBO) |
| Poles | 3P+N / 4 poles |
| Protected poles | 3 |
| Rated current | 16 A |
| Tripping characteristic | B |
| Residual-current type | Type A |
| Rated residual operating current | 30 mA |
| Rated voltage | 415 V AC |
| Rated insulation voltage | 500 V |
| Rated impulse withstand voltage | 4 kV |
| Frequency | 50 / 60 Hz |
| Rated short-circuit breaking capacity (Icn) | 10 kA |
| Breaking capacity according to IEC 60947-2 | 25 kA |
| Energy limiting class | 3 |
| Surge current withstand | 3 kA |
| Operating characteristic | Instantaneous / undelayed |
| Product standard | IEC/EN 61009-1 |
| Trip indication | DTI earth-fault indication |
| Mounting system | SMISSLINE TP plug-in system |
| Protection rating | IP20 |
| Module width | 4 modules |
| Installation depth | 78 mm |
| Power loss | 6.6 W |
| Operating temperature | −25 to +60 °C |
| Weight | approx. 0.42 kg |
It is a 3P+N RCBO designed to protect three-phase circuits with neutral against overload, short-circuit and residual-current faults within ABB SMISSLINE TP distribution systems.
The FS403M-B16/0.03 has a rated current of 16 A with a B tripping characteristic.
The device provides Type A residual-current protection with a rated residual operating current of 30 mA, detecting sinusoidal AC and pulsating DC residual currents.
The FS403M-B16/0.03 has a rated short-circuit breaking capacity of 10 kA according to EN 61009-1 and a breaking capacity of 25 kA according to IEC 60947-2.
The integrated DTI earth-fault indication helps identify residual-current operation, making fault diagnosis and maintenance easier.
ABB FS403M RCBOs combine three-phase overcurrent and Type A residual-current protection with clear fault indication and SMISSLINE TP plug-in installation for dependable protection of residential, commercial and industrial electrical circuits.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.