Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
ABB FS401MK-C32/0.3 is a 1P+N Type F 32 A C-curve RCBO with 300 mA residual-current protection, 10 kA breaking capacity, AP-R high-immunity operation and DTI earth-fault indication for the SMISSLINE TP plug-in system.
£180.97
The ABB FS401MK-C32/0.3 is a compact and dependable 1P+N Type F residual current circuit breaker with overcurrent protection (RCBO) designed for the ABB SMISSLINE TP plug-in system. It combines overload, short-circuit and residual-current protection in a single device, providing comprehensive protection for single-phase circuits in residential, commercial and industrial electrical installations.
This FS401MK model has a 32 A rated current, C tripping characteristic and 300 mA rated residual operating current. Its Type F residual-current detection is suitable for modern loads incorporating electronic equipment and single-phase inverter technology, while the AP-R high-immunity design provides increased resistance to unwanted tripping and supports continuity of service.
With a rated operational voltage of 240 V AC and a 10 kA rated short-circuit breaking capacity according to EN 61009-1, the FS401MK-C32/0.3 provides robust protection in a compact two-module format. Its integrated DTI earth-fault indication assists fault identification, while direct plug-in connection to the SMISSLINE TP system enables efficient installation and maintenance.
An RCBO combines miniature circuit-breaker and residual-current protection within one device. The ABB FS401MK-C32/0.3 therefore protects connected single-phase circuits against overload and short-circuit currents while monitoring for residual currents caused by insulation faults or current flowing to earth.
Its Type F characteristic is particularly suitable for circuits supplying modern electronic equipment and single-phase inverter loads, while the AP-R high-immunity design improves resistance to unwanted tripping. The 300 mA residual-current rating is intended for earth-fault protection rather than the additional direct-contact protection associated with 30 mA variants.
| Series | FS401MK / SMISSLINE TP |
|---|---|
| ABB order code | 2CCG001710R0001 |
| EAN / GTIN | 7612271521790 |
| Product type | Residual current circuit breaker with overcurrent protection (RCBO) |
| Poles | 1P+N |
| Protected poles | 1 |
| Rated current | 32 A |
| Tripping characteristic | C |
| Residual-current type | Type F |
| Rated residual operating current | 300 mA |
| Rated operational voltage | 240 V AC |
| Rated insulation voltage | 500 V |
| Rated impulse withstand voltage | 4 kV |
| Frequency | 50 / 60 Hz |
| Rated short-circuit breaking capacity (Icn) | 10 kA |
| Breaking capacity according to IEC 60947-2 | 15 kA |
| Energy limiting class | 3 |
| Surge current withstand | 3 kA |
| Product standard | IEC/EN 61009 |
| Trip indication | DTI earth-fault indicator |
| Mounting system | SMISSLINE TP plug-in system |
| Protection rating | IP20 |
| Module width | 2 modules |
| Width | 36 mm |
| Height | 91 mm |
| Depth | 68 mm |
| Installation depth | 78 mm |
| Power loss | 5.6 W |
| Operating temperature | −25 to +60 °C |
| Weight | approx. 0.2 kg |
It is a 1P+N RCBO designed to protect single-phase circuits against overload, short-circuit and residual-current faults within ABB SMISSLINE TP distribution systems.
The FS401MK-C32/0.3 has a rated current of 32 A with a C tripping characteristic.
The device provides Type F residual-current protection with a rated residual operating current of 300 mA.
The FS401MK-C32/0.3 has a rated short-circuit breaking capacity of 10 kA according to EN 61009-1 and a breaking capacity of 15 kA according to IEC 60947-2.
The integrated DTI earth-fault indicator helps identify when the RCBO has operated because of a residual-current fault, supporting faster troubleshooting and maintenance.
ABB FS401MK RCBOs combine overcurrent and Type F residual-current protection with high immunity to unwanted tripping, clear fault indication and SMISSLINE TP plug-in installation for dependable protection of modern single-phase electrical circuits.