Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
ABB FS401MKB200.03 (FS401MK-B20/0.03) is a 20 A 1P+N B characteristic Type F RCBO with 30 mA residual current sensitivity, 240 V AC rating and 10 kA breaking capacity for ABB SMISSLINE TP systems.
£152.26
The ABB FS401MKB200.03, type code FS401MK-B20/0.03, is a compact 1P+N Type F residual current circuit breaker with overcurrent protection (RCBO) designed for the ABB SMISSLINE TP plug-in system. It combines protection against overloads, short circuits and residual earth fault currents in one modular protective device for single-phase circuits in residential, commercial and industrial installations.
This RCBO has a 20 A rated current, B tripping characteristic and 30 mA Type F residual current sensitivity. Type F residual current protection is particularly suited to single-phase circuits supplying modern electronic equipment and inverters where mixed-frequency residual currents can occur, while the 30 mA sensitivity provides additional protection against direct contact.
With a rated operational voltage of 240 V AC and a 10 kA rated short-circuit breaking capacity according to EN 61009-1, the FS401MK-B20/0.03 provides robust combined protection in a compact two-module format. Its direct SMISSLINE TP plug-in connection supports efficient installation, replacement and flexible circuit configuration within compatible ABB distribution assemblies.
The ABB FS401MK-B20/0.03 combines miniature circuit breaker and Type F residual current protective functions in a single device. It protects single-phase circuits against overload and short-circuit currents while monitoring for residual earth fault currents, with its 30 mA sensitivity providing protection against indirect contact and additional protection against direct contact.
Type F residual current detection makes the FS401MK-B20/0.03 particularly suitable for single-phase electronic equipment and inverter-fed loads where mixed-frequency residual currents can occur. Combined with its B characteristic, 10 kA Icn rating and SMISSLINE TP plug-in architecture, it provides dependable protection with efficient installation, maintenance and circuit configuration.
| Product group | SMISSLINE Plug-in System |
|---|---|
| Series | FS401MK |
| Model / type code | FS401MK-B20/0.03 |
| SKU | FS401MKB200.03 |
| ABB order code | 2CCG001694R0001 |
| Product type | Residual current circuit breaker with overcurrent protection (RCBO) |
| Application | Single-phase circuit protection |
| Pole configuration | 1P+N |
| Number of poles | 2 |
| Number of protected poles | 1 |
| Rated current | 20 A |
| Overcurrent tripping characteristic | B |
| Residual current type | Type F |
| Rated residual current | 30 mA |
| Rated operational voltage | 240 V AC |
| Rated insulation voltage | 500 V |
| Rated impulse withstand voltage | 4 kV |
| Frequency | 50/60 Hz |
| Rated short-circuit breaking capacity (Icn) | 10 kA according to EN 61009-1 |
| Short-circuit breaking capacity according to IEC 60947-2 | 15 kA |
| Standard | IEC/EN 61009-1 |
| Energy limiting class | 3 |
| Surge current withstand | 3 kA |
| Power loss | 3 W |
| Overvoltage category | III |
| Pollution degree | 2 |
| Protection rating | IP20 |
| Operating ambient temperature | −25 to +60 °C |
| Width | 2 modules / 36 mm |
| Height | 91 mm |
| Depth | 78 mm |
| Installation depth | 78 mm |
| Multi-wired conductor capacity | 0.75–25 mm² |
| Installation system | ABB SMISSLINE TP plug-in system |
| EAN / GTIN | 7612271521639 |
| Product net weight | 0.2 kg |
| Pack unit | 1 piece |
The ABB FS401MKB200.03 is a 20 A 1P+N Type F RCBO for protecting single-phase circuits against overloads, short circuits and residual earth fault currents, including circuits supplying modern electronic equipment and single-phase inverters.
The FS401MK-B20/0.03 has a rated current of 20 A and a B tripping characteristic.
Type F residual current protection is designed for single-phase circuits where mixed-frequency residual currents can occur, including circuits supplying electronic equipment and single-phase inverters.
The FS401MK-B20/0.03 has a rated short-circuit breaking capacity (Icn) of 10 kA according to EN 61009-1 and a 15 kA breaking capacity according to IEC 60947-2 short-circuit testing.
It is designed for the ABB SMISSLINE TP plug-in system, allowing direct integration into compatible modular electrical distribution assemblies.
ABB FS401MK Type F RCBOs combine residual current and overcurrent protection with SMISSLINE TP plug-in technology, providing dependable protection for single-phase circuits including applications with modern electronic loads, inverters and mixed-frequency residual currents.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.