2CCG001690R0001 ABB FS401MKB60.03 FS401MK-B6/0.03 6 A 30 mA Type F 10 kA RCBO

2CCG001690R0001 ABB FS401MKB60.03 FS401MK-B6/0.03 6 A 30 mA Type F 10 kA RCBO

ABB FS401MKB60.03 (FS401MK-B6/0.03) is a 6 A 1P+N B characteristic Type F high-immunity RCBO with 30 mA residual current sensitivity, 240 V AC rating and 10 kA breaking capacity for ABB SMISSLINE TP systems.

SKU: 2CCG001690R0001Alt SKU: FS401MKB60.03MPN: 2CCG001690R0001
Price
List Price £215.34 ex VAT
Your Price (ex VAT) Save 35%
£139.97 35% OFF
You save £75.37 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £139.97
Trade pricing is personalised to your account

Manufacturer Lead Time

£139.97

Why Choose the ABB FS401MKB60.03 RCBO?

The ABB FS401MKB60.03, type code FS401MK-B6/0.03, is a compact 1P+N Type F residual current circuit breaker with overcurrent protection (RCBO) for the ABB SMISSLINE TP plug-in system. It combines protection against overloads, short circuits and residual earth fault currents in one modular protective device for single-phase circuits in residential, commercial and industrial installations.

This RCBO has a 6 A rated current, B tripping characteristic and 30 mA Type F residual current sensitivity. Type F protection is designed for mixed-frequency residual currents associated with modern single-phase electronic loads and inverters, while also detecting sinusoidal AC and pulsating DC residual currents. Its short-time-delayed, high-immunity characteristic provides increased resistance to unwanted tripping while maintaining 30 mA additional protection.

With a rated operational voltage of 240 V AC and a 10 kA rated short-circuit breaking capacity according to EN 61009-1, the FS401MK-B6/0.03 provides robust combined protection in a compact two-module format. Direct connection to the SMISSLINE TP plug-in system supports efficient installation, replacement and flexible circuit configuration within compatible ABB distribution assemblies.

Key Advantages

  • Combined residual current, overload and short-circuit protection in one RCBO.
  • 6 A rated current with B tripping characteristic.
  • 30 mA Type F residual current protection for modern single-phase electronic loads.
  • Suitable for circuits supplying single-phase inverters and frequency-controlled equipment.
  • Short-time-delayed, high-immunity operation improves resistance to unwanted tripping.
  • 10 kA rated short-circuit breaking capacity according to EN 61009-1.
  • 1P+N configuration with one protected pole.
  • Direct integration with the ABB SMISSLINE TP plug-in system.

Key Features

  • ABB FS401MK RCBO series.
  • FS401MK-B6/0.03 manufacturer type code.
  • 6 A rated current.
  • 1P+N configuration.
  • Type B overcurrent tripping characteristic.
  • Type F residual current characteristic.
  • 30 mA rated residual operating current.
  • 240 V AC rated operational voltage.
  • 10 kA Icn according to EN 61009-1.
  • 25 kA Icu short-circuit breaking capacity according to IEC 60947-2.
  • 3 kA maximum surge current.
  • Energy limiting class 3.
  • IP20 degree of protection.
  • Direct plug-in connection for the ABB SMISSLINE TP system.

Reliable Type F Combined Circuit and Residual Current Protection

The ABB FS401MK-B6/0.03 combines miniature circuit breaker and Type F residual current protective functions in one device. It protects single-phase circuits against overload and short-circuit currents while monitoring for earth leakage, and its 30 mA sensitivity provides additional protection against direct contact as well as protection against indirect contact.

Type F technology makes the RCBO particularly suitable for modern single-phase electronic equipment and circuits supplying inverters where mixed-frequency residual currents can occur. The short-time-delayed high-immunity characteristic helps resist unwanted tripping, while the B characteristic, 10 kA Icn rating and SMISSLINE TP plug-in architecture provide dependable protection and efficient system integration.

Typical Applications

  • Single-phase final circuit protection.
  • Circuits supplying single-phase inverters.
  • Electronic equipment capable of producing mixed-frequency residual currents.
  • Residential electrical distribution systems.
  • Commercial building installations.
  • Industrial electrical distribution and control circuits.
  • Applications requiring 30 mA Type F high-immunity protection.
  • Circuits requiring 10 kA short-circuit breaking capacity.
  • ABB SMISSLINE TP plug-in distribution systems.

Technical Specifications

Product group SMISSLINE Plug-in System
Series FS401MK
Model / type code FS401MK-B6/0.03
SKU FS401MKB60.03
ABB order code 2CCG001690R0001
Product type Residual current circuit breaker with overcurrent protection (RCBO)
Application Single-phase circuit protection
Pole configuration 1P+N
Number of poles 2
Number of protected poles 1
Rated current 6 A
Overcurrent tripping characteristic B
Residual current type Type F
Rated residual current 30 mA
Residual current characteristic Short-time delayed / high immunity
Rated operational voltage 240 V AC
Rated insulation voltage 500 V
Rated impulse withstand voltage 4 kV
Frequency 50/60 Hz
Rated short-circuit breaking capacity (Icn) 10 kA according to EN 61009-1
Rated ultimate short-circuit breaking capacity (Icu) 25 kA according to IEC 60947-2
Rated service short-circuit breaking capacity (Ics) 7.5 kA at 240 V AC
Rated residual breaking capacity 10 kA
Standards IEC/EN 61009-1, IEC/EN 61009-2-1 and IEC/EN 62423
Energy limiting class 3
Maximum surge current 3 kA
Power loss 1.9 W
Overvoltage category III
Pollution degree 2
Protection rating IP20
Operating ambient temperature −25 to +40 °C
Width 2 modules / 36 mm
Neutral terminal position Right
Installation system ABB SMISSLINE TP plug-in system
EAN / GTIN 7612271521592
Product weight 0.2 kg
Pack unit 1 piece

Frequently Asked Questions

What is the ABB FS401MKB60.03 used for?

The ABB FS401MKB60.03 is a 6 A 1P+N Type F RCBO for protecting single-phase circuits against overloads, short circuits and residual earth fault currents, with particular suitability for circuits supplying modern electronic loads and single-phase inverters.

What is the rated current and tripping characteristic of the FS401MK-B6/0.03?

The FS401MK-B6/0.03 has a rated current of 6 A and a B tripping characteristic.

What does Type F protection mean on the FS401MK-B6/0.03?

Type F residual current protection is designed to detect residual currents associated with single-phase electronic loads and frequency-controlled equipment, including mixed-frequency residual currents, while also responding to conventional AC and pulsating DC residual currents.

What is the short-circuit breaking capacity of the FS401MK-B6/0.03?

The FS401MK-B6/0.03 has a rated short-circuit breaking capacity (Icn) of 10 kA according to EN 61009-1.

Which ABB distribution system is the FS401MK-B6/0.03 designed for?

It is designed for the ABB SMISSLINE TP plug-in system, allowing direct integration into compatible modular electrical distribution assemblies.

Trusted ABB Type F Circuit Protection

ABB FS401MK Type F RCBOs combine residual current and overcurrent protection with high-immunity operation and SMISSLINE TP plug-in technology, providing dependable protection for single-phase circuits including applications with electronic loads, inverters and mixed-frequency residual currents.