2CCG001340R0001 ABB DS802P-D125/0.03AP-R RCBO 2P APR 125A 30mA

2CCG001340R0001 ABB DS802P-D125/0.03AP-R RCBO 2P APR 125A 30mA

ABB DS802P-D125/0.03AP-R is a two-pole 125 A D-curve APR RCBO with 30 mA residual-current sensitivity and 50 kA ultimate short-circuit breaking capacity for demanding industrial electrical protection.

SKU: 2CCG001340R0001Alt SKU: DS802PD1250.03APRMPN: 2CCG001340R0001
Price
List Price £1,171.62 ex VAT
Your Price (ex VAT) Save 35%
£761.55 35% OFF
You save £410.07 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £761.55
Trade pricing is personalised to your account

Manufacturer Lead Time

£761.55

Why Choose the ABB DS802P-D125/0.03AP-R RCBO?

The ABB DS802P-D125/0.03AP-R is a high-performance two-pole residual current circuit breaker with overcurrent protection (RCBO) designed for demanding industrial electrical distribution systems. Part of the ABB DS800P / S800P protection range, it combines overload, short-circuit and residual-current protection within a single protective device.

This RCBO has a rated current of 125 A, a D tripping characteristic and a rated residual operating current of 30 mA. Its Type APR residual-current protection provides enhanced resistance to unwanted tripping caused by transient leakage currents and disturbances, making it particularly useful in installations containing electronic equipment and loads where continuity of service is important.

With an ultimate short-circuit breaking capacity of 50 kA, the DS802P-D125/0.03AP-R provides robust protection for circuits with high prospective fault currents. The D characteristic accommodates equipment with substantial starting or inrush currents, while the sensitive 30 mA residual-current protection provides additional protection against electric shock. ABB order code 2CCG001340R0001 uniquely identifies this model.

Key Advantages

  • Combines overload, short-circuit and residual-current protection in one device.
  • 125 A rated current for demanding industrial circuits.
  • 30 mA rated residual operating current for additional protection against electric shock.
  • Type APR residual-current protection provides increased resistance to unwanted tripping.
  • D tripping characteristic suited to loads with high starting and inrush currents.
  • High 50 kA ultimate short-circuit breaking capacity.
  • Two-pole configuration for simultaneous circuit protection and isolation.
  • Well suited to industrial installations containing electronic or disturbance-producing loads.

Key Features

  • ABB DS800P / S800P high-performance protection range.
  • 2-pole RCBO configuration.
  • 125 A rated current.
  • D characteristic overcurrent release.
  • 30 mA residual-current sensitivity.
  • Type APR residual-current protection.
  • Enhanced immunity against transient disturbances and unwanted residual-current tripping.
  • Protection against overload and short-circuit currents.
  • Residual-current protection for electrical installations and connected loads.
  • 50 kA Icu ultimate short-circuit breaking capacity.

Reliable Protection with Enhanced Immunity to Unwanted Tripping

An RCBO combines overcurrent and residual-current protection so that a single device can respond to overloads, short circuits and earth leakage faults. The ABB DS802P-D125/0.03AP-R additionally uses a D characteristic, making it appropriate for circuits where normal equipment operation can produce high starting or inrush currents.

ABB APR residual-current devices are designed to provide greater resistance to unwanted tripping caused by transient disturbances while retaining dependable residual-current protection. This makes the DS802P-D125/0.03AP-R particularly suitable for installations where electronic loads, switching events or other transient conditions could otherwise affect continuity of service.

Typical Applications

  • Industrial electrical distribution systems.
  • Machinery circuits with high starting or inrush currents.
  • Industrial control panels and switchboards.
  • Circuits supplying electronic equipment.
  • Industrial motors, transformers and other inductive loads.
  • Installations requiring 30 mA residual-current protection.
  • Circuits where improved immunity to unwanted tripping is required.

Technical Specifications

Series DS800P / S800P
ABB order code 2CCG001340R0001
Product type Residual current circuit breaker with overcurrent protection (RCBO)
Number of poles 2
Rated current 125 A
Tripping characteristic D
Residual-current type APR
Rated residual operating current 30 mA (0.03 A)
Ultimate short-circuit breaking capacity (Icu) 50 kA
Application Industrial electrical distribution

Frequently Asked Questions

What is the ABB DS802P-D125/0.03AP-R used for?

The DS802P-D125/0.03AP-R provides combined overload, short-circuit and residual-current protection for demanding industrial electrical circuits, including applications with high starting currents and transient disturbances.

What is the rated current of the DS802P-D125/0.03AP-R?

The ABB DS802P-D125/0.03AP-R has a rated current of 125 A and uses a D tripping characteristic.

What residual-current sensitivity does this RCBO provide?

The device has a rated residual operating current of 30 mA (0.03 A), providing sensitive residual-current protection for industrial electrical installations.

What does APR mean on the ABB DS802P-D125/0.03AP-R?

APR identifies ABB residual-current protection designed with enhanced immunity to transient disturbances, helping reduce unwanted tripping in installations containing electronic and disturbance-producing loads.

What is the breaking capacity of the ABB DS802P-D125/0.03AP-R?

The DS802P-D125/0.03AP-R has an ultimate short-circuit breaking capacity (Icu) of 50 kA.

Trusted Industrial Circuit Protection from ABB

ABB DS800P protective devices combine high short-circuit performance with dependable overcurrent and residual-current protection, providing robust circuit protection for demanding industrial electrical distribution systems.