2CCG001331R0001 ABB DS804P-D125/1AS RCBO 4P 125 A 1000 mA Type AS

2CCG001331R0001 ABB DS804P-D125/1AS RCBO 4P 125 A 1000 mA Type AS

ABB DS804P-D125/1AS is a four-pole 125 A selective Type AS RCBO with 1000 mA residual-current protection and a D tripping characteristic for demanding industrial electrical distribution systems.

SKU: 2CCG001331R0001Alt SKU: DS804PD1251ASMPN: 2CCG001331R0001
Price
List Price £1,841.67 ex VAT
Your Price (ex VAT) Save 35%
£1,197.09 35% OFF
You save £644.58 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £1,197.09
Trade pricing is personalised to your account

Manufacturer Lead Time

£1,197.09

Why Choose the ABB DS804P-D125/1AS RCBO?

The ABB DS804P-D125/1AS is a high-performance four-pole residual current circuit breaker with overcurrent protection (RCBO) designed for demanding industrial electrical distribution systems. As part of the ABB DS800P high-performance circuit protection range, it combines protection against overloads, short circuits and residual earth fault currents within a single protective device.

This selective RCBO has a 125 A rated current and a 1000 mA (1 A) rated residual operating current. Its Type AS selective residual-current characteristic provides Type A residual-current detection with intentional time-delayed operation, supporting selective coordination with suitable downstream residual-current protective devices.

With a D tripping characteristic and four-pole configuration, the DS804P-D125/1AS is particularly suited to industrial circuits where substantial starting or inrush currents can occur. Its high-performance design makes it suitable for distribution boards, machinery and other industrial installations requiring combined overcurrent and selective residual-current protection.

Key Advantages

  • Combines residual-current, overload and short-circuit protection in one device.
  • 125 A rated current for demanding industrial circuits.
  • 1000 mA (1 A) rated residual current for earth-fault protection.
  • Type AS selective operation for coordinated residual-current protection.
  • D tripping characteristic suitable for circuits with high starting or inrush currents.
  • Four-pole configuration suitable for three-phase electrical distribution systems.
  • Selective time-delayed residual-current operation helps coordinate upstream and downstream protection.
  • Part of ABB's high-performance circuit protection range for industrial applications.

Key Features

  • ABB DS800P high-performance RCBO range.
  • 125 A rated current.
  • 1000 mA (1 A) rated residual operating current.
  • Four-pole design.
  • Type AS selective residual-current protection.
  • D overcurrent tripping characteristic.
  • Combined overload, short-circuit and residual-current protection.
  • Time-delayed residual-current operation for selective coordination.
  • Suitable for circuits containing equipment with substantial starting currents.
  • Designed for demanding industrial electrical distribution applications.

Selective Circuit Protection for Industrial Systems

RCBOs combine residual-current protection with overload and short-circuit protection, allowing several electrical fault conditions to be addressed by a single protective device. The ABB DS804P-D125/1AS is designed for industrial installations requiring a high rated current together with selective earth-fault protection.

The AS selective characteristic provides intentional time-delayed residual-current operation, helping achieve discrimination with appropriately selected downstream residual-current protective devices. Combined with its D overcurrent characteristic, the DS804P-D125/1AS is well suited to industrial systems containing motors, transformers and other equipment that can produce substantial starting or inrush currents.

Typical Applications

  • Industrial electrical distribution systems.
  • Three-phase industrial circuits.
  • Industrial machinery and production equipment.
  • Motor and transformer circuits with high starting currents.
  • Distribution boards and industrial switchgear assemblies.
  • Installations requiring selective residual-current protection.
  • Manufacturing and process automation systems.

Technical Specifications

Series DS800P
Product group S800 / S800P / S750 MCB
ABB order code 2CCG001331R0001
Product type Residual current circuit breaker with overcurrent protection (RCBO)
Residual-current type Type AS selective
Rated current 125 A
Rated residual current 1000 mA (1 A)
Tripping characteristic D
Number of poles 4P
Application Industrial circuit protection
Mounting DIN rail

Frequently Asked Questions

What is the ABB DS804P-D125/1AS used for?

The ABB DS804P-D125/1AS is an industrial RCBO designed to protect electrical circuits against overloads, short circuits and residual earth fault currents while providing selective residual-current operation.

What is the rated current of the DS804P-D125/1AS?

The device has a rated current of 125 A and uses a D tripping characteristic, making it suitable for industrial circuits where high starting or inrush currents may occur.

What is the residual-current rating?

The DS804P-D125/1AS has a rated residual operating current of 1000 mA (1 A) and uses an AS selective residual-current characteristic.

What does the AS designation mean on the DS804P-D125/1AS?

The AS designation indicates selective Type A residual-current protection with intentional time-delayed operation, helping coordinate the device with suitable downstream residual-current protective devices.

Where is the ABB DS804P-D125/1AS typically used?

The DS804P-D125/1AS is typically used in industrial distribution boards, machinery and three-phase electrical systems where combined overcurrent protection and selective residual-current protection are required.

Trusted Industrial Circuit Protection from ABB

ABB DS800P high-performance circuit protection devices are designed for demanding industrial installations, combining robust overcurrent protection with residual-current functionality and selective operation for dependable electrical distribution.