ABB DS802P-K125/1AS is a 2-pole 125 A K-curve selective Type AS RCBO with 1000 mA residual current sensitivity and 50 kA breaking capacity for industrial circuit protection.
£826.44
The ABB DS802P-K125/1AS is a high-performance 2-pole residual current circuit breaker with overcurrent protection (RCBO) designed to provide combined protection against overloads, short circuits and earth leakage faults in demanding industrial electrical installations. As part of the ABB DS800P series, it combines a rated current of 125 A, K tripping characteristic and selective Type AS residual current protection in a single protective device.
This RCBO provides protection against overload and short-circuit currents as well as the effects of sinusoidal alternating and pulsating DC earth fault currents. Its selective residual current operation incorporates an intentional tripping delay, helping achieve discrimination with suitable downstream instantaneous residual current protection devices and improving continuity of supply in coordinated installations.
With a rated residual operating current of 1000 mA and an ultimate short-circuit breaking capacity of 50 kA to IEC/EN 60947-2, the DS802P-K125/1AS is engineered for industrial circuits where high fault-current capability and dependable selective protection are required.
RCBOs combine the functions of a circuit breaker and residual current protective device, allowing a single unit to protect circuits against overload, short-circuit and earth leakage conditions. This integrated approach simplifies circuit protection while supporting reliable isolation and fault management.
The selective Type AS functionality of the DS802P-K125/1AS introduces an intentional operating delay for residual current faults. This makes the device particularly useful in coordinated protection systems where discrimination with downstream instantaneous devices can help limit unnecessary interruption of unaffected circuits.
| Series | DS800P |
|---|---|
| ABB order code | 2CCG001325R0001 |
| Product type | Residual current circuit breaker with overcurrent protection (RCBO) |
| Number of poles | 2 |
| Rated current | 125 A |
| Tripping characteristic | K |
| Residual current type | Type AS, selective |
| Rated residual operating current (IΔn) | 1000 mA |
| Ultimate short-circuit breaking capacity (Icu) | 50 kA |
| Rated voltage | 240 / 415 V AC |
| Standard | IEC/EN 60947-2 |
| Application | Industrial |
| Weight | approx. 0.803 kg |
The DS802P-K125/1AS provides combined protection against overload, short-circuit and residual earth fault currents in industrial electrical installations.
The RCBO has a rated current of 125 A with a K tripping characteristic.
The DS802P-K125/1AS has a rated residual operating current of 1000 mA and uses selective Type AS residual current protection.
The device has an ultimate short-circuit breaking capacity (Icu) of 50 kA according to IEC/EN 60947-2.
Selective Type AS operation incorporates an intentional tripping delay, allowing coordinated protection with suitable downstream instantaneous residual current devices and helping minimise unnecessary interruption of upstream circuits.