Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
ABB DS802P-C125/1AS is a two-pole 125 A C-curve Type AS selective RCBO with 1000 mA residual-current sensitivity and 50 kA ultimate short-circuit breaking capacity for industrial electrical protection.
£636.34
The ABB DS802P-C125/1AS is a high-performance two-pole residual current circuit breaker with overcurrent protection (RCBO) designed for industrial electrical distribution systems. As part of the ABB DS800P / S800P family, it combines protection against overloads, short circuits and residual earth fault currents within a single protective device.
This RCBO has a rated current of 125 A, a C tripping characteristic and a rated residual operating current of 1000 mA. Its Type AS selective residual-current protection incorporates an intentional tripping delay, supporting selective coordination with downstream instantaneous residual-current protective devices and helping improve continuity of supply in industrial installations.
With a rated ultimate short-circuit breaking capacity of 50 kA and compliance with IEC/EN 60947-2, the DS802P-C125/1AS is suited to demanding industrial applications where high fault-current capability and coordinated residual-current protection are required. ABB order code 2CCG001323R0001 uniquely identifies this two-pole, 125 A model.
An RCBO combines the functions of overcurrent and residual-current protection, allowing a single device to respond to overloads, short circuits and earth leakage faults. This simplifies protective coordination while helping safeguard electrical equipment, wiring and installations against several common fault conditions.
The ABB DS802P-C125/1AS uses selective Type AS residual-current operation with an intentional tripping delay. This characteristic allows appropriate downstream instantaneous residual-current devices to operate first, supporting discrimination between protective devices and helping minimise unnecessary interruption of upstream circuits in correctly coordinated installations.
| Series | DS800P / S800P |
|---|---|
| ABB order code | 2CCG001323R0001 |
| Product type | Residual current circuit breaker with overcurrent protection (RCBO) |
| Number of poles | 2 |
| Rated current | 125 A |
| Tripping characteristic | C |
| Residual-current type | Type AS selective |
| Rated residual operating current | 1000 mA (1 A) |
| Ultimate short-circuit breaking capacity (Icu) | 50 kA |
| Standard | IEC/EN 60947-2 |
| Application | Industrial electrical distribution |
| EAN | 7612271517922 |
| Dimensions (H × W × D) | 108.2 × 137 × 82.3 mm |
| Weight | approx. 0.803 kg |
The DS802P-C125/1AS provides combined overload, short-circuit and residual-current protection for demanding industrial electrical distribution circuits.
The ABB DS802P-C125/1AS has a rated current of 125 A and uses a C tripping characteristic.
The device has a rated residual operating current of 1000 mA (1 A) and uses selective Type AS residual-current protection.
The DS802P-C125/1AS has an ultimate short-circuit breaking capacity (Icu) of 50 kA.
Type AS provides Type A residual-current detection with an intentional tripping delay, allowing selective coordination with suitable downstream instantaneous protective devices and helping prevent unnecessary upstream disconnection.
ABB DS800P protective devices combine high short-circuit performance with dependable overcurrent and residual-current protection, providing a robust solution for demanding industrial electrical distribution and selective protection systems.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.