2CCG001313R0001 ABB DS802P-K125/0.3A 2-Pole Type A 125A 300mA RCBO

2CCG001313R0001 ABB DS802P-K125/0.3A 2-Pole Type A 125A 300mA RCBO

ABB DS802P-K125/0.3A is a 2-pole 125 A Type A 300 mA RCBO with Type K overcurrent characteristic for combined residual-current, overload and short-circuit protection.

SKU: 2CCG001313R0001Alt SKU: DS802PK1250.3AMPN: 2CCG001313R0001
Price
List Price £1,116.10 ex VAT
Your Price (ex VAT) Save 35%
£725.47 35% OFF
You save £390.64 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £725.47
Trade pricing is personalised to your account

Manufacturer Lead Time

£725.47

Why Choose the ABB DS802P-K125/0.3A RCBO?

The ABB DS802P-K125/0.3A is a high-performance 2-pole residual current circuit breaker with overcurrent protection (RCBO) designed to combine residual-current, overload and short-circuit protection in a single protective device. This model has a 125 A rated current and 300 mA rated residual operating current.

The DS802P-K125/0.3A uses a Type K overcurrent tripping characteristic, making it particularly suitable for appropriate circuits supplying inductive equipment with elevated functional starting or inrush currents. Its Type A residual-current characteristic provides detection of sinusoidal AC residual currents and pulsating DC residual currents.

With its 2-pole configuration, the DS802P-K125/0.3A integrates multiple protective functions into one device for demanding electrical distribution applications. ABB order code 2CCG001313R0001 identifies this specific 125 A, 300 mA Type A RCBO with K overcurrent characteristic.

Key Advantages

  • Combines residual-current, overload and short-circuit protection in one device.
  • 125 A rated current for substantial electrical loads and distribution circuits.
  • 300 mA rated residual operating current.
  • Type A residual-current characteristic for AC and pulsating DC residual currents.
  • Type K overcurrent characteristic suited to appropriate inductive loads with elevated functional starting currents.
  • 2-pole configuration for coordinated circuit protection.
  • RCBO functionality combines residual-current and overcurrent protection within a single protective device.
  • ABB order code 2CCG001313R0001 provides precise product identification.

Key Features

  • ABB DS802P high-performance RCBO.
  • Two-pole configuration.
  • 125 A rated current.
  • 300 mA residual operating current.
  • Type A residual-current characteristic.
  • Type K overcurrent tripping characteristic.
  • Integrated residual-current protection.
  • Integrated overload protection.
  • Integrated short-circuit protection.

Combined Protection for Demanding Inductive Circuits

The ABB DS802P-K125/0.3A integrates residual-current monitoring with overcurrent protection, allowing one device to respond to earth-leakage conditions as well as circuit overloads and short circuits. Its Type A residual-current characteristic is designed to detect sinusoidal AC residual currents and pulsating DC residual currents.

The Type K overcurrent characteristic is particularly suited to appropriate inductive circuits that can experience elevated current during normal starting or energisation. Combined with its 125 A current rating and 300 mA residual-current sensitivity, the DS802P-K125/0.3A provides integrated protection for demanding motor, transformer, machinery and electrical distribution applications.

Typical Applications

  • Industrial electrical distribution systems.
  • Commercial electrical distribution installations.
  • Circuits requiring combined residual-current and overcurrent protection.
  • Motor and inductive equipment circuits.
  • Transformer and machinery circuits with elevated functional inrush currents.
  • Electrical control panels and distribution assemblies.
  • High-current circuits requiring a 125 A RCBO.
  • Applications specified for 300 mA Type A residual-current protection.

Technical Specifications

Series DS802P
ABB order code 2CCG001313R0001
Product type Residual current circuit breaker with overcurrent protection (RCBO)
Number of poles 2
Rated current 125 A
Overcurrent tripping characteristic K
Residual-current type A
Rated residual operating current 300 mA
Protection functions Residual current, overload and short-circuit protection
Product group S800 / S800P / S750 MCB

Frequently Asked Questions

What is the ABB DS802P-K125/0.3A?

The ABB DS802P-K125/0.3A is a 2-pole RCBO that combines residual-current protection with overload and short-circuit protection in a single device.

What is the rated current of the DS802P-K125/0.3A?

The DS802P-K125/0.3A has a rated current of 125 A.

What is the residual-current sensitivity of this RCBO?

The DS802P-K125/0.3A has a rated residual operating current of 300 mA.

What does Type A mean on the DS802P-K125/0.3A?

Type A describes the residual-current characteristic and provides detection of sinusoidal AC residual currents as well as pulsating DC residual currents.

What does the Type K characteristic mean?

The Type K overcurrent characteristic is suited to appropriate inductive circuits with elevated functional starting or inrush currents, including suitable motor, transformer and machinery applications.

Integrated Circuit Protection from ABB

ABB DS802P RCBOs combine residual-current and overcurrent protection in a single device, supporting dependable protection of demanding electrical distribution and equipment circuits.