2CCG001312R0001 ABB DS802P-D125/0.3A 2-Pole Type A 125A 300mA RCBO

2CCG001312R0001 ABB DS802P-D125/0.3A 2-Pole Type A 125A 300mA RCBO

ABB DS802P-D125/0.3A is a 2-pole 125 A Type A 300 mA RCBO with Type D overcurrent characteristic for combined residual-current, overload and short-circuit protection.

SKU: 2CCG001312R0001Alt SKU: DS802PD1250.3AMPN: 2CCG001312R0001
Price
List Price £1,116.10 ex VAT
Your Price (ex VAT) Save 35%
£725.47 35% OFF
You save £390.64 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £725.47
Trade pricing is personalised to your account

Manufacturer Lead Time

£725.47

Why Choose the ABB DS802P-D125/0.3A RCBO?

The ABB DS802P-D125/0.3A is a high-performance 2-pole residual current circuit breaker with overcurrent protection (RCBO) designed to combine residual-current, overload and short-circuit protection in a single protective device. This model has a 125 A rated current and 300 mA rated residual operating current.

The DS802P-D125/0.3A uses a Type D overcurrent tripping characteristic, making it suitable for appropriate circuits where connected equipment can produce substantial functional starting or inrush currents. Its Type A residual-current characteristic provides residual-current detection for AC residual currents and pulsating DC residual currents.

With its 2-pole configuration, the DS802P-D125/0.3A combines multiple protective functions within one device for demanding electrical distribution applications. ABB order code 2CCG001312R0001 identifies this specific 125 A, 300 mA Type A RCBO.

Key Advantages

  • Combines residual-current, overload and short-circuit protection in one device.
  • 125 A rated current for substantial electrical loads and distribution circuits.
  • 300 mA rated residual operating current.
  • Type A residual-current characteristic for AC and pulsating DC residual currents.
  • Type D overcurrent characteristic suited to appropriate loads with substantial functional inrush currents.
  • 2-pole configuration for coordinated circuit protection.
  • RCBO functionality reduces the need for separate residual-current and overcurrent protective devices.
  • ABB order code 2CCG001312R0001 provides precise product identification.

Key Features

  • ABB DS802P high-performance RCBO.
  • Two-pole configuration.
  • 125 A rated current.
  • 300 mA residual operating current.
  • Type A residual-current characteristic.
  • Type D overcurrent tripping characteristic.
  • Integrated residual-current protection.
  • Integrated overload protection.
  • Integrated short-circuit protection.

Combined Residual-Current and Overcurrent Protection

The ABB DS802P-D125/0.3A integrates residual-current monitoring with overcurrent protection, allowing one device to respond to earth-leakage conditions as well as circuit overloads and short circuits. Its Type A residual-current characteristic is designed to detect sinusoidal AC residual currents and pulsating DC residual currents.

The Type D overcurrent characteristic is suited to appropriate circuits that experience substantial functional current peaks during normal starting or energisation. Combined with its 125 A current rating and 300 mA residual-current sensitivity, the DS802P-D125/0.3A provides integrated protection for demanding electrical distribution and equipment circuits.

Typical Applications

  • Industrial electrical distribution systems.
  • Commercial electrical distribution installations.
  • Circuits requiring combined residual-current and overcurrent protection.
  • Industrial machinery and equipment circuits.
  • Circuits with substantial functional starting or inrush currents.
  • Electrical control panels and distribution assemblies.
  • High-current circuits requiring a 125 A RCBO.
  • Applications specified for 300 mA Type A residual-current protection.

Technical Specifications

Series DS802P
ABB order code 2CCG001312R0001
Product type Residual current circuit breaker with overcurrent protection (RCBO)
Number of poles 2
Rated current 125 A
Overcurrent tripping characteristic D
Residual-current type A
Rated residual operating current 300 mA
Protection functions Residual current, overload and short-circuit protection
Product group S800 / S800P / S750 MCB

Frequently Asked Questions

What is the ABB DS802P-D125/0.3A?

The ABB DS802P-D125/0.3A is a 2-pole RCBO that combines residual-current protection with overload and short-circuit protection in a single device.

What is the rated current of the DS802P-D125/0.3A?

The DS802P-D125/0.3A has a rated current of 125 A.

What is the residual-current sensitivity of this RCBO?

The DS802P-D125/0.3A has a rated residual operating current of 300 mA.

What does Type A mean on the DS802P-D125/0.3A?

Type A describes the residual-current characteristic and provides detection of sinusoidal AC residual currents as well as pulsating DC residual currents.

What does the Type D characteristic mean?

The Type D overcurrent characteristic is suited to appropriate circuits with substantial functional starting or inrush currents, including certain motor, transformer and other inductive-load applications.

Integrated Circuit Protection from ABB

ABB DS802P RCBOs combine residual-current and overcurrent protection in a single device, supporting dependable protection of demanding electrical distribution and equipment circuits.