2CCG001243R0001 ABB S802P-D125 2-Pole Type D 125A 50kA High-Performance MCB

2CCG001243R0001 ABB S802P-D125 2-Pole Type D 125A 50kA High-Performance MCB

ABB S802P-D125 is a 2-pole 125 A Type D high-performance miniature circuit breaker with 50 kA breaking capacity for overload and short-circuit protection in demanding industrial and commercial electrical systems.

SKU: 2CCG001243R0001Alt SKU: S802PD125MPN: 2CCG001243R0001
Price
List Price £293.19 ex VAT
Your Price (ex VAT) Save 35%
£190.57 35% OFF
You save £102.62 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £190.57
Trade pricing is personalised to your account

Manufacturer Lead Time

£190.57

Why Choose the ABB S802P-D125 High-Performance MCB?

The ABB S802P-D125 is a high-performance 2-pole miniature circuit breaker (MCB) designed to provide reliable overload and short-circuit protection in demanding industrial and commercial electrical installations. Part of the ABB S800P high-performance MCB series, this model combines a substantial 125 A rated current, D tripping characteristic and high 50 kA breaking capacity.

The S802P-D125 is particularly suited to circuits where high prospective fault currents and substantial functional inrush currents must both be accommodated. Its Type D characteristic allows higher instantaneous currents than B or C characteristic breakers, making it well suited to equipment such as transformers, motors and other inductive loads with significant energisation or starting currents.

With two protected poles, the S802P-D125 provides coordinated switching and protection of both conductors in suitable distribution circuits. Its high current rating and robust S800P construction make it a strong choice for industrial distribution, machinery and equipment protection where conventional miniature circuit breakers may not provide sufficient short-circuit performance. ABB order code 2CCG001243R0001 identifies this specific 125 A Type D model.

Key Advantages

  • High-performance 2-pole miniature circuit breaker for demanding electrical systems.
  • 125 A rated current suitable for higher-current feeder and distribution circuits.
  • High 50 kA breaking capacity for installations with substantial prospective fault currents.
  • Type D tripping characteristic suited to loads with high functional starting or inrush currents.
  • Provides combined overload and short-circuit protection.
  • Two-pole configuration provides coordinated protection and isolation of both conductors.
  • Suitable for motors, transformers and other inductive industrial loads.
  • Part of ABB’s proven S800P high-performance circuit protection platform.

Key Features

  • ABB S800P high-performance MCB series.
  • Two-pole circuit breaker configuration.
  • 125 A rated current.
  • D tripping characteristic.
  • 50 kA short-circuit breaking capacity.
  • Thermal-magnetic protection against overload and short-circuit conditions.
  • Type D characteristic accommodates substantial functional inrush currents.
  • Designed for demanding commercial and industrial electrical distribution.
  • Suitable for high-current circuits with elevated prospective short-circuit levels.

Reliable Protection for High-Inrush Industrial Loads

The ABB S802P-D125 combines thermal overload protection with rapid magnetic short-circuit protection. Sustained excessive current causes the thermal mechanism to operate, while severe short-circuit currents trigger fast magnetic disconnection, helping protect conductors and connected equipment against damaging thermal and electrodynamic stresses.

The Type D characteristic is particularly useful for circuits where equipment can draw substantial current during normal start-up or energisation. This makes the S802P-D125 well suited to industrial motors, transformers and other inductive equipment while its 50 kA breaking capacity provides the short-circuit performance required for demanding distribution systems.

Typical Applications

  • Industrial electrical distribution systems.
  • Motor and machinery circuits with high starting currents.
  • Transformer protection circuits.
  • Industrial automation and production equipment.
  • High-current feeder circuits.
  • Electrical control panels and distribution assemblies.
  • Inductive loads with substantial functional inrush currents.
  • Installations with high prospective short-circuit currents.

Technical Specifications

Series S800P
ABB order code 2CCG001243R0001
Product type High-performance miniature circuit breaker (MCB)
Number of poles 2
Rated current 125 A
Tripping characteristic D
Breaking capacity 50 kA
Protection function Overload and short-circuit protection
Trip technology Thermal-magnetic
Product group S800 / S800P / S750 MCB

Frequently Asked Questions

What is the ABB S802P-D125 used for?

The ABB S802P-D125 is a high-performance miniature circuit breaker designed to protect high-current electrical circuits against overloads and short circuits, including circuits supplying loads with substantial starting or inrush currents.

What is the rated current of the ABB S802P-D125?

The S802P-D125 has a rated current of 125 A.

What is the breaking capacity of the S802P-D125?

The S802P-D125 has a specified short-circuit breaking capacity of 50 kA, making it suitable for demanding installations with high prospective fault currents.

What does the Type D characteristic mean?

The Type D characteristic accommodates relatively high functional starting and inrush currents, making it suitable for loads such as motors, transformers and other inductive industrial equipment.

How many poles does the ABB S802P-D125 have?

The S802P-D125 is a 2-pole high-performance miniature circuit breaker, providing coordinated switching and protection of both poles.

Trusted High-Performance Protection from ABB

ABB S800P high-performance miniature circuit breakers provide robust overload and short-circuit protection for demanding commercial and industrial electrical systems, combining high current ratings, substantial breaking capacity and tripping characteristics tailored to different load types.