2CCG000564R0001 ABB S401P-C10NP MCB 40 kA 1P+NP Type C 10 A

2CCG000564R0001 ABB S401P-C10NP MCB 40 kA 1P+NP Type C 10 A

ABB S401P-C10NP 1P+NP 10 A Type C miniature circuit breaker with protected neutral and 40 kA Icu breaking capacity, designed for the SMISSLINE TP plug-in distribution system.

SKU: 2CCG000564R0001Alt SKU: S401PC10NPMPN: 2CCG000564R0001
Price
List Price £89.23 ex VAT
Your Price (ex VAT) Save 35%
£58.00 35% OFF
You save £31.23 per unit
Manufacturer Lead Time Estimated Delivery 7 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £58.00
Trade pricing is personalised to your account

Manufacturer Lead Time

£58.00

Why Choose the ABB S401P-C10NP Miniature Circuit Breaker?

The ABB S401P-C10NP is a high-performance 1P+NP miniature circuit breaker (MCB) with protected neutral, designed to protect electrical circuits against overload and short-circuit currents. Part of the ABB S400P series for the SMISSLINE TP plug-in system, it combines current-limiting circuit protection with ABB's flexible plug-in distribution architecture.

Featuring a Type C tripping characteristic and a rated current of 10 A, the S401P-C10NP is suitable for compatible circuits where moderate transient or inrush currents may occur. Its phase-plus-protected-neutral configuration provides protection for phase and neutral conductors in a compact two-module SMISSLINE TP format.

With a rated ultimate short-circuit breaking capacity of 40 kA according to IEC/EN 60947-2, the S401P-C10NP provides robust fault protection for demanding commercial and industrial installations. Its plug-in construction enables integration with compatible SMISSLINE TP socket-base assemblies, supporting efficient installation, replacement and maintenance.

Key Advantages

  • 1P+NP configuration with protected neutral for phase-and-neutral circuit protection.
  • 10 A rated current for appropriately rated electrical circuits.
  • Type C tripping characteristic for circuits where moderate inrush currents may occur.
  • High 40 kA Icu breaking capacity according to IEC/EN 60947-2.
  • Current-limiting protection against overload and short-circuit conditions.
  • Designed specifically for the ABB SMISSLINE TP plug-in system.

Key Features

  • ABB S400P miniature circuit breaker series.
  • 1P+NP phase and protected-neutral configuration.
  • 10 A rated current.
  • Type C tripping characteristic.
  • 40 kA Icu rated ultimate short-circuit breaking capacity.
  • Conforms to IEC/EN 60947-2.
  • 2-module device format.
  • 0.230 kg unit weight.
  • Direct integration with compatible SMISSLINE TP socket-base systems.

Reliable Phase and Neutral Circuit Protection

The ABB S401P-C10NP uses a delayed thermal tripping mechanism for overload protection together with an electromechanical tripping mechanism for short-circuit protection. Automatic disconnection under overcurrent conditions helps protect conductors and connected electrical equipment against thermal and electrical damage.

The ABB SMISSLINE TP system uses a plug-in architecture that enables compatible protective devices to connect directly to its socket-base system. Combined with the S401P-C10NP's protected-neutral configuration, 10 A rating and 40 kA Icu breaking capacity, this provides an efficient protection solution for professional industrial and commercial electrical distribution.

Typical Applications

  • Industrial electrical distribution boards.
  • Commercial power distribution systems.
  • Phase-and-neutral branch circuits.
  • Machinery and industrial control panels.
  • Automation and manufacturing installations.
  • Control and auxiliary electrical circuits.
  • ABB SMISSLINE TP plug-in distribution assemblies.

Technical Specifications

Series S400P
Product system SMISSLINE TP Plug-in System
ABB order code 2CCG000564R0001
EAN / GTIN 7612271509309
Product type Miniature circuit breaker (MCB)
Pole configuration 1P+NP
Neutral Protected neutral
Rated current 10 A
Tripping characteristic Type C
Rated ultimate short-circuit breaking capacity (Icu) 40 kA
Standard IEC/EN 60947-2
Number of modules 2
Weight 0.230 kg
Pack quantity 5 pieces
Mounting type SMISSLINE TP plug-in socket-base system

Frequently Asked Questions

What is the ABB S401P-C10NP used for?

The ABB S401P-C10NP is a 1P+NP miniature circuit breaker with protected neutral, designed to protect suitable phase-and-neutral electrical circuits against overload and short-circuit currents within compatible SMISSLINE TP systems.

What is the rated current of the S401P-C10NP?

The S401P-C10NP has a rated current of 10 A.

What tripping characteristic does the S401P-C10NP use?

The S401P-C10NP uses a Type C tripping characteristic, making it suitable for appropriate circuits where moderate transient or inrush currents may occur.

What is the breaking capacity of the ABB S401P-C10NP?

The S401P-C10NP has a rated ultimate short-circuit breaking capacity (Icu) of 40 kA according to IEC/EN 60947-2.

Which ABB distribution system is the S401P-C10NP designed for?

The circuit breaker is designed for the ABB SMISSLINE TP plug-in system, enabling integration with compatible socket-base electrical distribution assemblies.

Trusted ABB Circuit Protection

ABB SMISSLINE TP circuit protection products combine dependable electrical protection with a flexible plug-in architecture, supporting efficient installation, expansion and maintenance in professional industrial and commercial distribution systems.