2CCG000496R0001 ABB S402P-B2 MCB 40 kA 2P Type B 2 A

2CCG000496R0001 ABB S402P-B2 MCB 40 kA 2P Type B 2 A

ABB S402P-B2 is a 2 A Type B 2-pole miniature circuit breaker with 40 kA ultimate short-circuit breaking capacity for the SMISSLINE TP plug-in system.

SKU: 2CCG000496R0001Alt SKU: S402PB2MPN: 2CCG000496R0001
Price
List Price £112.42 ex VAT
Your Price (ex VAT) Save 35%
£73.07 35% OFF
You save £39.35 per unit
Manufacturer Lead Time Estimated Delivery 7 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £73.07
Trade pricing is personalised to your account

Manufacturer Lead Time

£73.07

Why Choose the ABB S402P-B2 Miniature Circuit Breaker?

The ABB S402P-B2 is a high-performance 2-pole miniature circuit breaker (MCB) designed for reliable overload and short-circuit protection in low-voltage electrical distribution systems. As part of the ABB S400P range for the SMISSLINE TP plug-in system, it combines dependable circuit protection with a flexible plug-in architecture for commercial and industrial installations.

This MCB features a Type B tripping characteristic and a rated current of 2 A, making it suitable for circuits with relatively low starting currents. The S400P range protects cables and conductors against overload and short-circuit conditions, while its plug-in format supports efficient installation and modification within compatible SMISSLINE TP distribution systems.

With an ultimate short-circuit breaking capacity of 40 kA and a 2-pole configuration, the S402P-B2 provides high fault-current performance in a compact two-module device. ABB order code 2CCG000496R0001 identifies this specific 2 A Type B version of the S402P range.

Key Advantages

  • High-performance miniature circuit breaker for the SMISSLINE TP plug-in system.
  • 2 A rated current for low-current electrical circuits.
  • Type B tripping characteristic suitable for resistive and inductive loads with low starting currents.
  • 40 kA ultimate short-circuit breaking capacity for demanding installations.
  • 2-pole configuration provides simultaneous circuit protection across two poles.
  • Energy limiting class 3 for effective fault-current limitation.
  • Plug-in architecture supports efficient installation, maintenance and system expansion.

Key Features

  • ABB S400P miniature circuit breaker range.
  • SMISSLINE TP plug-in system compatibility.
  • 2 A rated current.
  • Type B characteristic.
  • 2-pole configuration with both poles protected.
  • 40 kA Icu ultimate short-circuit breaking capacity.
  • 440 V rated insulation voltage.
  • 4 kV rated impulse withstand voltage.
  • Two-module device format.
  • Designed in accordance with IEC/EN 60947-2.

Reliable Circuit Protection for SMISSLINE TP Systems

Miniature circuit breakers such as the ABB S402P-B2 protect electrical cables and circuits against overload and short-circuit currents. The Type B characteristic is intended for circuits with comparatively low inrush currents, making this device suitable for many resistive and low-inrush inductive loads in commercial and industrial electrical systems.

The ABB SMISSLINE TP system uses a plug-in distribution architecture that allows compatible protective devices to connect directly to the socket system. This approach supports flexible electrical distribution designs while helping simplify installation, servicing and future modifications within control panels and distribution assemblies.

Typical Applications

  • Low-voltage electrical distribution systems.
  • Commercial and industrial distribution boards.
  • Low-current control and auxiliary circuits.
  • Resistive and low-inrush inductive loads.
  • Control panels and electrical switchboards.
  • Machinery and industrial automation systems.
  • ABB SMISSLINE TP plug-in distribution assemblies.

Technical Specifications

Product group SMISSLINE Plug-in System
Series S400P
ABB order code 2CCG000496R0001
Product type Miniature circuit breaker (MCB)
Rated current 2 A
Tripping characteristic Type B
Pole configuration 2P
Total poles 2
Protected poles 2
Ultimate short-circuit breaking capacity (Icu) 40 kA
Rated frequency 50–60 Hz
Rated insulation voltage (Ui) 440 V
Rated impulse withstand voltage (Uimp) 4 kV
Energy limiting class 3
Overvoltage category III
Pollution degree 3
Standard IEC/EN 60947-2
Number of modules 2
Width 36 mm
Height 85 mm
Installation depth 91 mm
Operating ambient temperature -25 to +60 °C
Solid conductor connection 0.75–35 mm²
Stranded conductor connection 0.75–25 mm²
Power loss 2.6 W
Weight 0.230 kg
EAN / GTIN 7612271508692
Packaging unit 5 pieces
Mounting system SMISSLINE TP plug-in socket system

Frequently Asked Questions

What is the ABB S402P-B2 used for?

The S402P-B2 is a two-pole miniature circuit breaker designed to provide overload and short-circuit protection for low-voltage circuits within the ABB SMISSLINE TP plug-in system.

What is the rated current of the ABB S402P-B2?

The S402P-B2 has a rated current of 2 A and a Type B tripping characteristic.

What is the breaking capacity of the S402P-B2?

The S402P-B2 has an ultimate short-circuit breaking capacity (Icu) of 40 kA.

How many poles does the ABB S402P-B2 have?

The S402P-B2 is a 2-pole MCB with two protected poles and occupies two modules within the SMISSLINE TP system.

What is the ABB order code for the S402P-B2?

The ABB order code for the S402P-B2 is 2CCG000496R0001.