2CCG000446R0001 ABB S402P-K8 MCB 40 kA 2P K 8 A

2CCG000446R0001 ABB S402P-K8 MCB 40 kA 2P K 8 A

ABB S402P-K8 is an 8 A two-pole K characteristic miniature circuit breaker with 40 kA Icu breaking capacity for the SMISSLINE TP plug-in system.

SKU: 2CCG000446R0001Alt SKU: S402PK8MPN: 2CCG000446R0001
Price
List Price £101.11 ex VAT
Your Price (ex VAT) Save 35%
£65.72 35% OFF
You save £35.39 per unit
Manufacturer Lead Time Estimated Delivery 7 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £65.72
Trade pricing is personalised to your account

Manufacturer Lead Time

£65.72

Why Choose the ABB S402P-K8 Miniature Circuit Breaker?

The ABB S402P-K8 is a high-performance two-pole miniature circuit breaker (MCB) designed to protect electrical circuits against overload and short-circuit conditions. Part of the ABB S400P range for the SMISSLINE TP plug-in system, it combines an 8 A rated current, K tripping characteristic and high short-circuit breaking capacity for demanding industrial and commercial electrical distribution applications.

The S402P-K8 provides protection across two poles and is designed for direct integration into compatible ABB SMISSLINE TP distribution assemblies. Its plug-in construction supports efficient installation, replacement and expansion while maintaining the compact modular architecture of the SMISSLINE TP system.

With a rated current of 8 A and an ultimate short-circuit breaking capacity (Icu) of 40 kA at both 230 V and 400 V according to IEC 60947-2, the S402P-K8 provides robust protection for circuits where elevated starting or inrush currents may occur. The breaker occupies two modules and weighs approximately 0.230 kg.

Key Advantages

  • High-performance 8 A miniature circuit breaker for overload and short-circuit protection.
  • 40 kA Icu breaking capacity for demanding electrical distribution applications.
  • K tripping characteristic suited to appropriate circuits with elevated starting and inrush currents.
  • Two-pole configuration provides coordinated protection and switching of two conductors.
  • Designed specifically for the ABB SMISSLINE TP plug-in system.
  • Compact two-module construction supports efficient installation and system expansion.

Key Features

  • ABB S400P miniature circuit breaker series.
  • 8 A rated current.
  • 2-pole configuration with two protected poles.
  • K characteristic according to IEC/EN 60947-2.
  • 40 kA ultimate short-circuit breaking capacity (Icu).
  • 415 V rated voltage.
  • 50–60 Hz operating frequency.
  • IP20 protection rating.
  • Direct plug-in integration with the SMISSLINE TP system.

Reliable Circuit Protection for SMISSLINE TP Systems

Miniature circuit breakers such as the ABB S402P-K8 protect cables and connected electrical circuits by automatically interrupting current when overload or short-circuit conditions occur. Its K tripping characteristic makes the breaker suitable for appropriate circuits where elevated transient starting currents may occur while dependable overcurrent protection remains essential.

The S402P-K8 combines two-pole protection with ABB's SMISSLINE TP plug-in architecture. This provides a compact and flexible solution for professional distribution assemblies where straightforward installation, efficient servicing, high fault-breaking capability and future system expansion are required.

Typical Applications

  • ABB SMISSLINE TP electrical distribution systems.
  • Industrial control and automation panels.
  • Commercial and industrial distribution boards.
  • Control and auxiliary power circuits.
  • Circuits requiring coordinated two-pole protection and isolation.
  • Equipment circuits with elevated starting or inrush currents.

Technical Specifications

Series S400P / SMISSLINE TP
ABB order code 2CCG000446R0001
Product type Miniature circuit breaker (MCB)
Rated current 8 A
Rated voltage 415 V
Number of poles 2
Number of protected poles 2
Tripping characteristic K
Ultimate short-circuit breaking capacity (Icu) at 230 V 40 kA
Ultimate short-circuit breaking capacity (Icu) at 400 V 40 kA
Standard IEC/EN 60947-2
Frequency 50–60 Hz
Rated insulation voltage (Ui) 440 V
Rated impulse withstand voltage (Uimp) 4 kV
Current limiting class 3
Overvoltage category III
Pollution degree 3
Protection rating IP20
Operating temperature -25 to +60 °C
Installation depth 91 mm
Number of modules 2
Power loss 2.4 W
Solid conductor connection 0.75–35 mm²
Stranded conductor connection 0.75–25 mm²
System SMISSLINE TP plug-in system
Weight 0.230 kg
Pack quantity 5 pieces
EAN / GTIN 7612271510138

Frequently Asked Questions

What is the ABB S402P-K8 used for?

The ABB S402P-K8 is a two-pole miniature circuit breaker designed to protect electrical circuits against overload and short-circuit conditions within SMISSLINE TP distribution systems.

What is the rated current of the S402P-K8?

The S402P-K8 has a rated current of 8 A.

What breaking capacity does the S402P-K8 provide?

The S402P-K8 provides an ultimate short-circuit breaking capacity (Icu) of 40 kA at both 230 V and 400 V according to IEC 60947-2.

What does the K characteristic mean on the S402P-K8?

The K tripping characteristic is suitable for appropriate circuits where elevated starting or inrush currents can occur while dependable overload and short-circuit protection is required.

Which ABB system is the S402P-K8 designed for?

The S402P-K8 is designed for the ABB SMISSLINE TP plug-in system and occupies two modules within a compatible distribution assembly.

Trusted ABB Circuit Protection

ABB S400P miniature circuit breakers combine dependable overload and short-circuit protection with the modular flexibility of the SMISSLINE TP plug-in system, supporting efficient installation and reliable operation in professional electrical distribution applications.