2CCG000417R0001 ABB S401P-K13 MCB 40kA 1P Type K 13A

2CCG000417R0001 ABB S401P-K13 MCB 40kA 1P Type K 13A

ABB S401P-K13 is a 13 A Type K 1-pole miniature circuit breaker with 40 kA ultimate short-circuit breaking capacity, designed for overload and short-circuit protection in SMISSLINE TP plug-in distribution systems.

SKU: 2CCG000417R0001Alt SKU: S401PK13MPN: 2CCG000417R0001
Price
List Price £37.02 ex VAT
Your Price (ex VAT) Save 35%
£24.06 35% OFF
You save £12.96 per unit
Manufacturer Lead Time Estimated Delivery 7 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £24.06
Trade pricing is personalised to your account

Manufacturer Lead Time

£24.06

Why Choose the ABB S401P-K13 Miniature Circuit Breaker?

The ABB S401P-K13 is a high-performance 1-pole miniature circuit breaker (MCB) designed to provide reliable overload and short-circuit protection in commercial and industrial electrical distribution systems. Part of the ABB S400P range for the SMISSLINE TP plug-in system, it combines current-limiting circuit protection with a compact plug-in format for compatible distribution assemblies.

The S401P-K13 incorporates a delayed thermal tripping mechanism for overload protection together with an electromechanical tripping mechanism for short-circuit protection. Its Type K tripping characteristic according to IEC/EN 60947-2 makes it particularly suitable for circuits where higher starting or inrush currents can occur during normal operation.

With a rated current of 13 A, a 1-pole configuration and a rated ultimate short-circuit breaking capacity of 40 kA, the S401P-K13 provides robust protection in a compact format. ABB order code 2CCG000417R0001 and GTIN 7612271509873 identify this specific 13 A Type K version.

Key Advantages

  • High-performance 1-pole miniature circuit breaker for overload and short-circuit protection.
  • 13 A rated current for distribution, control and equipment circuits.
  • Type K tripping characteristic suited to applications with higher starting or inrush currents.
  • 40 kA ultimate short-circuit breaking capacity for demanding electrical installations.
  • Delayed thermal overload and electromechanical short-circuit tripping mechanisms.
  • Current-limiting design helps reduce the effects of short-circuit fault currents.
  • Plug-in construction designed specifically for the ABB SMISSLINE TP system.

Key Features

  • ABB S400P / SMISSLINE TP series.
  • 13 A rated current.
  • 1-pole configuration.
  • Type K tripping characteristic.
  • 40 kA rated ultimate short-circuit breaking capacity.
  • Type K characteristic according to IEC/EN 60947-2.
  • Current-limiting miniature circuit breaker design.
  • Connection terminal accepts conductors up to 35 mm².
  • IP20 protection at the connection terminal.
  • Direct plug-in connection to the compatible SMISSLINE TP socket system.
  • Compact 1-module construction.

Reliable Type K Circuit Protection

The ABB S401P-K13 protects cables, conductors and connected equipment against damaging overload and short-circuit currents. Its delayed thermal trip responds to sustained overload conditions, while the electromechanical trip provides rapid interruption during short-circuit faults. The Type K characteristic is particularly useful where connected equipment can produce elevated starting currents during normal operation.

The ABB SMISSLINE TP plug-in architecture enables the S401P-K13 to connect directly to the compatible socket system, supporting efficient assembly, servicing and modification of electrical distribution installations. Its combination of a 13 A rating, Type K characteristic and 40 kA breaking capacity makes it a robust choice for professional circuits requiring compact single-pole protection.

Typical Applications

  • Industrial electrical distribution systems.
  • Machine and automation control panels.
  • SMISSLINE TP plug-in distribution assemblies.
  • Commercial electrical distribution boards.
  • Control and auxiliary circuits.
  • Equipment circuits with elevated starting or inrush currents.
  • Single-pole branch circuit overload and short-circuit protection.

Technical Specifications

Series S400P / SMISSLINE TP
ABB order code 2CCG000417R0001
EAN / GTIN 7612271509873
Product type Miniature circuit breaker (MCB)
Rated current 13 A
Number of poles 1
Tripping characteristic Type K
Rated ultimate short-circuit breaking capacity 40 kA
Standard IEC/EN 60947-2
Maximum conductor cross-section 35 mm²
Protection at connection terminal IP20
Mounting system SMISSLINE TP plug-in system
Module width 1 module
Width 18 mm
Height 85 mm
Weight approx. 115 g
Pack unit 10 pieces

Frequently Asked Questions

What is the ABB S401P-K13 used for?

The ABB S401P-K13 is a 1-pole miniature circuit breaker designed to protect compatible electrical circuits against overload and short-circuit currents in ABB SMISSLINE TP distribution systems.

What is the rated current of the S401P-K13?

The ABB S401P-K13 has a rated current of 13 A.

What tripping characteristic does the S401P-K13 use?

The S401P-K13 uses a Type K tripping characteristic according to IEC/EN 60947-2, making it suitable for applications where higher starting or inrush currents can occur.

What is the breaking capacity of the ABB S401P-K13?

The S401P-K13 has a rated ultimate short-circuit breaking capacity of 40 kA.

Which mounting system is the S401P-K13 designed for?

The S401P-K13 is designed exclusively for the ABB SMISSLINE TP plug-in system, enabling direct installation within compatible SMISSLINE TP electrical distribution assemblies.

Trusted Circuit Protection from ABB

ABB SMISSLINE TP S400P miniature circuit breakers combine dependable overload and short-circuit protection with a practical plug-in architecture for professional commercial and industrial electrical distribution systems.