2CCG000410R0001 ABB S403P-C63NP MCB 20kA 3P+NP Type C 63A

2CCG000410R0001 ABB S403P-C63NP MCB 20kA 3P+NP Type C 63A

ABB S403P-C63NP is a 63 A Type C 3P+NP miniature circuit breaker with 20 kA ultimate short-circuit breaking capacity, designed for overload and short-circuit protection in SMISSLINE TP plug-in distribution systems.

SKU: 2CCG000410R0001Alt SKU: S403PC63NPMPN: 2CCG000410R0001
Price
List Price £319.09 ex VAT
Your Price (ex VAT) Save 35%
£207.41 35% OFF
You save £111.68 per unit
Manufacturer Lead Time Estimated Delivery 7 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £207.41
Trade pricing is personalised to your account

Manufacturer Lead Time

£207.41

Why Choose the ABB S403P-C63NP Miniature Circuit Breaker?

The ABB S403P-C63NP is a high-performance 3P+NP miniature circuit breaker (MCB) designed to protect cables and electrical circuits against overload and short-circuit currents in three-phase-plus-neutral distribution systems. Part of the ABB S400P range for the SMISSLINE TP plug-in system, it combines current-limiting circuit protection with a practical plug-in architecture for compatible commercial, industrial and critical power installations.

The S403P-C63NP incorporates two complementary tripping mechanisms: a delayed thermal mechanism for overload protection and an electromechanical mechanism for short-circuit protection. Its Type C tripping characteristic is suitable for circuits where moderate starting or inrush currents can occur, while its four-pole 3P+NP arrangement is designed for three-phase-plus-neutral applications.

With a rated current of 63 A, a 3P+NP configuration and a rated ultimate short-circuit breaking capacity of 20 kA, the S403P-C63NP provides robust protection for demanding distribution systems. ABB order code 2CCG000410R0001 and GTIN 7612271509804 identify this specific 63 A Type C version.

Key Advantages

  • 3P+NP configuration for three-phase-plus-neutral electrical distribution circuits.
  • 63 A rated current for higher-current commercial and industrial applications.
  • Type C tripping characteristic suitable for circuits with moderate starting or inrush currents.
  • 20 kA ultimate short-circuit breaking capacity for demanding distribution systems.
  • Delayed thermal overload and electromechanical short-circuit tripping mechanisms.
  • Current-limiting design helps reduce the effects of short-circuit fault currents.
  • Plug-in construction designed specifically for the ABB SMISSLINE TP system.

Key Features

  • ABB S400P / SMISSLINE TP series.
  • 63 A rated current.
  • 3P+NP / four-pole configuration.
  • Type C tripping characteristic.
  • 20 kA rated ultimate short-circuit breaking capacity.
  • Designed in accordance with IEC/EN 60947-2.
  • 50–60 Hz operating frequency.
  • 4 kV rated impulse withstand voltage.
  • Connection terminals accommodate conductors up to 35 mm².
  • Direct plug-in connection to the compatible SMISSLINE TP socket system.
  • Compact 4-module construction.

Reliable Protection for Three-Phase-Plus-Neutral Circuits

The ABB S403P-C63NP protects cables and conductors against damaging overload and short-circuit currents. Its delayed thermal tripping mechanism responds to sustained overload conditions, while the electromechanical mechanism provides rapid operation during short-circuit faults, helping to limit fault energy within the electrical installation.

The 3P+NP arrangement makes the S403P-C63NP suitable for compatible three-phase-plus-neutral distribution circuits. Combined with the ABB SMISSLINE TP plug-in architecture, the breaker supports efficient installation and servicing while delivering 63 A Type C protection with a 20 kA short-circuit breaking capacity.

Typical Applications

  • Three-phase-plus-neutral electrical distribution systems.
  • Industrial electrical distribution assemblies.
  • Commercial building distribution boards.
  • SMISSLINE TP plug-in distribution systems.
  • Machine and automation power distribution panels.
  • Higher-current three-phase equipment circuits with neutral.
  • Critical power distribution applications.
  • Branch circuit overload and short-circuit protection.

Technical Specifications

Series S400P / SMISSLINE TP
ABB order code 2CCG000410R0001
EAN / GTIN 7612271509804
Product type Miniature circuit breaker (MCB)
Rated current 63 A
Pole configuration 3P+NP / 4 poles
Tripping characteristic Type C
Rated ultimate short-circuit breaking capacity 20 kA
Rated impulse withstand voltage (Uimp) 4 kV
Frequency 50–60 Hz
Standard IEC/EN 60947-2
Pollution degree 3
Overvoltage category III
Maximum conductor cross-section 35 mm²
Mounting system SMISSLINE TP plug-in system
Module width 4 modules
Installation depth 91 mm
Power loss 22 W
Weight approx. 460 g
Packaging unit 2 pieces

Frequently Asked Questions

What is the ABB S403P-C63NP used for?

The ABB S403P-C63NP is a 3P+NP miniature circuit breaker designed to protect compatible three-phase-plus-neutral circuits against overload and short-circuit currents in ABB SMISSLINE TP distribution systems.

What is the rated current of the S403P-C63NP?

The ABB S403P-C63NP has a rated current of 63 A.

What tripping characteristic does the S403P-C63NP use?

The S403P-C63NP uses a Type C tripping characteristic, making it suitable for circuits where moderate starting or inrush currents may occur.

What is the breaking capacity of the ABB S403P-C63NP?

The S403P-C63NP has a rated ultimate short-circuit breaking capacity of 20 kA.

Which mounting system is the S403P-C63NP designed for?

The S403P-C63NP is designed exclusively for the ABB SMISSLINE TP plug-in system, allowing direct connection within compatible SMISSLINE TP electrical distribution assemblies.

Trusted Circuit Protection from ABB

ABB SMISSLINE TP S400P miniature circuit breakers combine dependable overload and short-circuit protection with a practical plug-in architecture for professional commercial, industrial and critical power distribution systems.