2CCG000402R0001 ABB S403P-C13NP MCB 40kA 3P+NP Type C 13A

2CCG000402R0001 ABB S403P-C13NP MCB 40kA 3P+NP Type C 13A

ABB S403P-C13NP is a 13 A Type C 3P+NP miniature circuit breaker with four protected poles and 40 kA ultimate short-circuit breaking capacity, designed for SMISSLINE TP plug-in distribution systems.

SKU: 2CCG000402R0001Alt SKU: S403PC13NPMPN: 2CCG000402R0001
Price
List Price £194.36 ex VAT
Your Price (ex VAT) Save 35%
£126.33 35% OFF
You save £68.03 per unit
Manufacturer Lead Time Estimated Delivery 7 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £126.33
Trade pricing is personalised to your account

Manufacturer Lead Time

£126.33

Why Choose the ABB S403P-C13NP Miniature Circuit Breaker?

The ABB S403P-C13NP is a high-performance 3P+NP miniature circuit breaker (MCB) designed for reliable overload and short-circuit protection in three-phase-plus-neutral electrical distribution systems. Part of the ABB S400P range for the SMISSLINE TP plug-in system, it combines current-limiting circuit protection with a practical plug-in architecture for compatible distribution assemblies.

The S403P-C13NP uses thermal overload protection together with electromagnetic short-circuit protection to safeguard cables, conductors and connected equipment. Its Type C tripping characteristic is suitable for circuits where moderate starting or inrush currents can occur, while its protected-neutral configuration provides coordinated protection for three phase conductors and the neutral.

With a rated current of 13 A, a 3P+NP configuration and a rated ultimate short-circuit breaking capacity of 40 kA, the S403P-C13NP provides robust protection for demanding commercial and industrial installations. ABB order code 2CCG000402R0001 identifies this specific 13 A Type C version for the SMISSLINE TP system.

Key Advantages

  • 3P+NP configuration for three-phase-plus-neutral circuit protection.
  • 13 A rated current for distribution, control and auxiliary circuits.
  • Type C tripping characteristic suitable for circuits with moderate inrush currents.
  • 40 kA ultimate short-circuit breaking capacity for demanding electrical distribution applications.
  • Thermal overload and electromagnetic short-circuit protection mechanisms.
  • Plug-in construction designed for the ABB SMISSLINE TP system.

Key Features

  • ABB S400P / SMISSLINE TP series.
  • 13 A rated current.
  • 3P+NP / four-pole configuration.
  • Type C tripping characteristic.
  • 40 kA rated ultimate short-circuit breaking capacity.
  • Type C characteristic according to IEC/EN 60947-2.
  • Current-limiting miniature circuit breaker design.
  • 440 V rated insulation voltage.
  • 4 kV rated impulse withstand voltage.
  • Direct plug-in installation within compatible SMISSLINE TP distribution assemblies.

Reliable Protection for Three-Phase-Plus-Neutral Circuits

The ABB S403P-C13NP provides overload and short-circuit protection across its four protected poles. Its thermal trip responds to sustained overload conditions, while the electromagnetic trip provides rapid operation during short-circuit faults, helping to protect conductors, connected equipment and the wider electrical installation.

The 3P+NP arrangement makes the S403P-C13NP suitable for compatible three-phase-plus-neutral circuits where protection of the neutral conductor is required. Combined with the ABB SMISSLINE TP plug-in architecture, the device provides a practical solution for professional distribution systems requiring high breaking capacity and efficient installation.

Typical Applications

  • Three-phase-plus-neutral electrical distribution systems.
  • Industrial electrical distribution assemblies.
  • Commercial building distribution boards.
  • SMISSLINE TP plug-in distribution systems.
  • Machine and automation control panels.
  • Three-phase auxiliary and equipment circuits with neutral.
  • Branch circuit overload and short-circuit protection.

Technical Specifications

Series S400P / SMISSLINE TP
ABB order code 2CCG000402R0001
EAN / GTIN 7612271509736
Product type Miniature circuit breaker (MCB)
Rated current 13 A
Pole configuration 3P+NP / 4 poles
Protected poles 4
Tripping characteristic Type C
Rated ultimate short-circuit breaking capacity 40 kA
Rated insulation voltage (Ui) 440 V
Rated impulse withstand voltage (Uimp) 4 kV
Frequency 50–60 Hz
Standard IEC/EN 60947-2
Energy limiting class 3
Pollution degree 3
Overvoltage category III
Solid conductor cross-section 0.75–35 mm²
Stranded conductor cross-section 0.75–25 mm²
Operating ambient temperature -25 to +60 °C
Mounting system SMISSLINE TP plug-in system
Module width 4 modules
Installation depth 91 mm
Power loss 6.8 W
Weight approx. 460 g
Pack unit 2 pieces

Frequently Asked Questions

What is the ABB S403P-C13NP used for?

The ABB S403P-C13NP is a 3P+NP miniature circuit breaker designed to provide overload and short-circuit protection for compatible three-phase-plus-neutral circuits in ABB SMISSLINE TP distribution systems.

What is the rated current of the S403P-C13NP?

The ABB S403P-C13NP has a rated current of 13 A.

What does 3P+NP mean on the S403P-C13NP?

The 3P+NP configuration provides three phase poles together with a protected neutral pole, giving four protected poles for suitable three-phase-plus-neutral circuits.

What is the breaking capacity of the ABB S403P-C13NP?

The S403P-C13NP has a rated ultimate short-circuit breaking capacity of 40 kA.

Which mounting system is the S403P-C13NP designed for?

The S403P-C13NP is designed for the ABB SMISSLINE TP plug-in system, allowing installation within compatible SMISSLINE TP electrical distribution assemblies.

Trusted Circuit Protection from ABB

ABB SMISSLINE TP S400P miniature circuit breakers combine dependable overload and short-circuit protection with a practical plug-in architecture for professional commercial and industrial electrical distribution systems.