2CCG000056R0001 ABB F404B-40/0.3 RCCB 4P Type B 300 mA 40 A

2CCG000056R0001 ABB F404B-40/0.3 RCCB 4P Type B 300 mA 40 A

ABB F404B-40/0.3 is a 40 A 4-pole Type B RCCB with 300 mA rated residual current for the ABB SMISSLINE TP plug-in system, providing residual-current protection for demanding commercial and industrial installations.

SKU: 2CCG000056R0001Alt SKU: F404B400.3MPN: 2CCG000056R0001
Price
List Price £1,087.38 ex VAT
Your Price (ex VAT) Save 35%
£706.80 35% OFF
You save £380.58 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £706.80
Trade pricing is personalised to your account

Manufacturer Lead Time

£706.80

Why Choose the ABB F404B-40/0.3 RCCB?

The ABB F404B-40/0.3 is a 40 A, 4-pole Type B residual current circuit breaker (RCCB) designed for direct integration with the ABB SMISSLINE TP plug-in system. With a rated residual operating current of 300 mA, it provides residual-current protection for demanding commercial and industrial low-voltage installations.

Type B residual-current detection makes the F404B-40/0.3 suitable for circuits where sinusoidal AC, pulsating DC and smooth DC residual currents may occur, including installations containing power-electronic equipment. The device is also short-time delayed and offers a surge-current withstand capability of 3 kA, helping improve operational reliability in demanding electrical systems.

Rated at 40 A and 400 V AC, the F404B-40/0.3 combines four-pole switching with a 300 mA residual-current rating. Its plug-in design allows direct connection to the SMISSLINE TP socket-base system, while ABB order code 2CCG000056R0001 identifies this specific Type B configuration.

Key Advantages

  • Type B residual-current detection for AC, pulsating DC and smooth DC fault currents.
  • 40 A rated current for commercial and industrial circuits.
  • 300 mA rated residual current for residual-current and fire-protection applications.
  • 4-pole configuration for three-phase systems with neutral.
  • Direct plug-in integration with the ABB SMISSLINE TP system.
  • Short-time delayed operation and 3 kA surge-current withstand support reliable operation in demanding installations.

Key Features

  • Type B RCCB.
  • 40 A rated current.
  • 300 mA rated residual operating current.
  • 4 poles.
  • 400 V AC rated voltage.
  • 500 V rated insulation voltage.
  • 4 kV rated impulse withstand voltage.
  • 3 kA surge-current withstand capability.
  • Short-time delayed operation.
  • Plug-in connection for ABB SMISSLINE TP socket bases.

Type B Residual-Current Protection for SMISSLINE TP Systems

Modern commercial and industrial installations increasingly contain electronic equipment capable of generating residual currents with waveforms that extend beyond conventional sinusoidal AC. Type B RCCBs are designed to detect a broad range of residual-current forms, including smooth DC and residual currents associated with power-electronic equipment such as frequency converters.

The ABB F404B-40/0.3 combines this Type B detection capability with a 40 A current rating, 300 mA residual-current sensitivity and direct SMISSLINE TP plug-in connection. This makes it particularly suitable for modular distribution systems where dependable residual-current protection and efficient installation are required.

Typical Applications

  • ABB SMISSLINE TP plug-in distribution systems.
  • Commercial and industrial low-voltage distribution boards.
  • Circuits containing frequency converters and power-electronic equipment.
  • Three-phase installations where smooth DC residual currents may occur.
  • Industrial machinery and automation systems.
  • Electrical installations requiring 300 mA Type B residual-current protection.

Technical Specifications

Series F404 B / SMISSLINE TP
Product type Residual Current Circuit Breaker (RCCB)
ABB order code 2CCG000056R0001
EAN / GTIN 7612271506322
Residual-current type Type B
Number of poles 4
Rated current 40 A
Rated residual current 300 mA
Rated voltage 400 V AC
Rated insulation voltage 500 V
Rated impulse withstand voltage 4 kV
Surge-current withstand 3 kA
Short-time delayed Yes
Operating temperature -25 to +55 °C
Pollution degree 2
Degree of protection IP20
Installation depth 97 mm
Width 70 mm
Connectable conductor cross-section 1–25 mm²
Power loss 9.6 W
Net weight 0.435 kg
Pack quantity 1 piece
System compatibility ABB SMISSLINE TP plug-in system
Applicable Type B standard IEC/EN 62423

Frequently Asked Questions

What is the ABB F404B-40/0.3 used for?

The F404B-40/0.3 is a 4-pole Type B RCCB used to provide residual-current protection in compatible ABB SMISSLINE TP electrical distribution systems, particularly where AC, pulsating DC or smooth DC residual currents may occur.

What are the current and residual-current ratings of the F404B-40/0.3?

The ABB F404B-40/0.3 has a rated current of 40 A and a rated residual operating current of 300 mA.

What does Type B mean on the ABB F404B-40/0.3?

Type B indicates that the RCCB is designed to detect a broad range of residual currents, including sinusoidal AC, pulsating DC and smooth DC residual currents, making it suitable for installations containing certain types of power-electronic equipment.

Is the ABB F404B-40/0.3 compatible with SMISSLINE TP?

Yes. The F404B-40/0.3 is specifically designed as a plug-in RCCB for the ABB SMISSLINE TP system, allowing direct integration with compatible socket-base assemblies.

What is the ABB order code for the F404B-40/0.3?

The ABB order code for the F404B-40/0.3 is 2CCG000056R0001.

Trusted ABB SMISSLINE Protection Technology

ABB SMISSLINE protection devices combine modular plug-in installation with coordinated electrical protection, helping panel builders and electrical installers create organised, expandable and dependable low-voltage distribution assemblies.