2CCF544310E0630 ABB F404A-K63/0.03 RCCB 4P Type A 30mA 63A Short-Time Delayed

2CCF544310E0630 ABB F404A-K63/0.03 RCCB 4P Type A 30mA 63A Short-Time Delayed

ABB F404A-K63/0.03 is a 63 A four-pole Type A 30 mA short-time delayed residual current circuit breaker rated at 230/400 V for plug-in installation in ABB SMISSLINE TP low-voltage distribution systems.

SKU: 2CCF544310E0630Alt SKU: F404AK630.03MPN: 2CCF544310E0630
Price
List Price £447.18 ex VAT
Your Price (ex VAT) Save 35%
£290.67 35% OFF
You save £156.51 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £290.67
Trade pricing is personalised to your account

Manufacturer Lead Time

£290.67

Why Choose the ABB F404A-K63/0.03 RCCB?

The ABB F404A-K63/0.03 is a short-time delayed Type A residual current circuit breaker (RCCB) designed for the ABB SMISSLINE TP plug-in distribution system. Rated at 63 A with a rated residual operating current of 30 mA, it provides four-pole residual-current protection for compatible low-voltage circuits.

As part of the ABB F404 K series, this RCCB combines Type A residual-current detection with a short-time delayed operating characteristic. It is sensitive to sinusoidal AC and pulsating DC residual currents, while the delayed characteristic provides increased resistance to unwanted tripping caused by short-duration transient leakage currents.

The F404A-K63/0.03 features a four-pole configuration, 63 A rated current, 30 mA residual-current sensitivity and 230/400 V rated voltage. It occupies four SMISSLINE space units and integrates directly with the modular SMISSLINE TP system for efficient and flexible distribution-board assembly.

Key Advantages

  • Short-time delayed RCCB for increased resistance to transient nuisance tripping.
  • Purpose-designed for the ABB SMISSLINE TP plug-in distribution system.
  • 63 A rated current for higher-current low-voltage circuits.
  • 30 mA rated residual operating current.
  • Four-pole configuration suitable for three-phase and neutral circuits.
  • Type A protection detects sinusoidal AC and pulsating DC residual currents.

Key Features

  • ABB F404 K RCCB series.
  • Short-time delayed K characteristic.
  • 63 A rated current.
  • 30 mA rated residual operating current.
  • Type A residual-current characteristic.
  • Four-pole design.
  • 230/400 V rated voltage.
  • 50–60 Hz rated frequency.
  • Integrated input wiring and contact-position indication.
  • Upper input terminals can be used for supply feed.
  • Pluggable in compatible positions within the SMISSLINE TP system.
  • Occupies 4 SMISSLINE space units.

Short-Time Delayed Type A Residual-Current Protection

Residual current circuit breakers monitor the balance of current flowing through the protected conductors and disconnect the circuit when residual current reaches the device's operating threshold. The F404A-K63/0.03 combines 30 mA Type A residual-current protection with ABB's short-time delayed K characteristic, providing increased immunity to brief transient residual currents.

The ABB F404 K series is designed specifically for integration with the SMISSLINE TP plug-in distribution system. Integrated input wiring, flexible plug-in positioning and a double-level output terminal arrangement help provide an efficient solution for commercial and industrial distribution assemblies requiring dependable residual-current protection.

Typical Applications

  • ABB SMISSLINE TP distribution boards.
  • Three-phase and neutral circuits requiring residual-current protection.
  • Circuits where increased immunity to transient nuisance tripping is desirable.
  • Commercial low-voltage distribution systems.
  • Industrial electrical distribution assemblies.
  • Circuits requiring short-time delayed Type A 30 mA residual-current protection.

Technical Specifications

Series F404 K / SMISSLINE TP
ABB order code 2CCF544310E0630
Product type Short-time delayed residual current circuit breaker (RCCB)
Residual-current type Type A
Tripping characteristic K, short-time delayed
Number of poles 4
Rated current 63 A
Rated residual operating current 30 mA
Rated voltage 230/400 V
Frequency 50–60 Hz
Power loss 3.2 W
Space units 4
Mounting type SMISSLINE TP plug-in / conductor bar mounting
Standard EN 61008-1
Dimensions (W × H × D) 72 × 91 × 75 mm
Weight 0.430 kg
Pack unit 1 piece
System ABB SMISSLINE TP

Frequently Asked Questions

What is the ABB F404A-K63/0.03 used for?

It is a four-pole short-time delayed Type A RCCB designed to provide residual-current protection in compatible ABB SMISSLINE TP low-voltage distribution systems.

What is the current rating of the F404A-K63/0.03?

The RCCB has a rated current of 63 A.

What is the residual-current sensitivity?

The F404A-K63/0.03 has a rated residual operating current of 30 mA.

What does the K designation mean on the ABB F404A-K63/0.03?

The K designation identifies the short-time delayed version of the ABB F404 RCCB, providing increased resistance to unwanted operation from brief transient residual currents.

What is the ABB order code for the F404A-K63/0.03?

The ABB order code for the F404A-K63/0.03 is 2CCF544310E0630.

Trusted ABB Short-Time Delayed Residual-Current Protection

ABB F404 K residual current circuit breakers combine short-time delayed Type A residual-current protection with the modular plug-in architecture of the SMISSLINE TP system, supporting dependable and flexible low-voltage distribution installations.