2CCF019999R0001 ABB S802S-UCK0.5 MCB 50 kA 2P Type K 0.5 A

2CCF019999R0001 ABB S802S-UCK0.5 MCB 50 kA 2P Type K 0.5 A

ABB S802S-UCK0.5 is a 0.5 A two-pole Type K high-performance miniature circuit breaker with 50 kA ultimate short-circuit breaking capacity at 500 V DC for demanding commercial and industrial DC circuit protection.

SKU: 2CCF019999R0001Alt SKU: S802SUCK0.5MPN: 2CCF019999R0001
Price
List Price £267.47 ex VAT
Your Price (ex VAT) Save 35%
£173.86 35% OFF
You save £93.61 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £173.86
Trade pricing is personalised to your account

Manufacturer Lead Time

£173.86

Why Choose the ABB S802S-UCK0.5 High Performance MCB?

The ABB S802S-UCK0.5 is a high-performance two-pole miniature circuit breaker (MCB) designed to protect direct-current electrical circuits against overloads and short circuits where a high breaking capacity is required. As part of the ABB S800S-UC high-performance circuit breaker range, it provides robust protection for demanding commercial and industrial electrical installations.

This circuit breaker features a UC-K / Type K tripping characteristic, a rated current of 0.5 A and an ultimate short-circuit breaking capacity of 50 kA at 500 V DC. The Type K characteristic is particularly suitable for circuits containing inductive loads and equipment with functional starting currents, while the low 0.5 A rating enables protection of sensitive control and auxiliary circuits.

The S802S-UCK0.5 combines a two-pole configuration with ABB's S800S-UC platform dedicated to DC applications. Its high fault-current capability, robust construction and specialised K characteristic make it suitable for demanding systems requiring reliable circuit protection where conventional miniature circuit breakers may not provide sufficient breaking capacity.

Key Advantages

  • High-performance miniature circuit breaker for demanding DC applications.
  • 0.5 A rated current for sensitive low-current circuit protection.
  • 50 kA ultimate short-circuit breaking capacity at 500 V DC.
  • Two-pole configuration for coordinated protection and switching.
  • UC-K / Type K characteristic suitable for circuits with inductive loads and functional starting currents.
  • Dedicated to direct-current circuit protection.
  • Suitable for demanding commercial and industrial installations.

Key Features

  • ABB S800S-UC high-performance MCB series.
  • 0.5 A rated current.
  • 2-pole configuration.
  • UC-K / Type K tripping characteristic.
  • 50 kA ultimate short-circuit breaking capacity at 500 V DC.
  • Protection against overloads and short circuits.
  • 500 V DC rated application voltage.
  • Designed to IEC/EN 60947-2 requirements.
  • Suitable for connection of auxiliary devices.
  • High-performance design for installations with demanding prospective fault-current requirements.

High-Performance Type K DC Circuit Protection

High-performance miniature circuit breakers such as the ABB S800S-UC series automatically interrupt electrical circuits during overload and short-circuit conditions. The 50 kA breaking capacity at 500 V DC of the S802S-UCK0.5 makes it suitable for demanding direct-current installations where high prospective fault currents require robust protective devices.

The UC-K / Type K characteristic is intended for applications where functional starting or inrush currents may occur, including circuits supplying inductive equipment. Combined with its low 0.5 A rating and two-pole construction, the S802S-UCK0.5 provides specialised protection for sensitive control, auxiliary and industrial DC circuits.

Typical Applications

  • Direct-current electrical circuits.
  • Low-current control and auxiliary circuits.
  • Industrial machinery and automation systems.
  • Circuits supplying inductive loads.
  • Electrical distribution and control panels.
  • Instrumentation and monitoring circuits.
  • Applications requiring high short-circuit breaking capacity.

Technical Specifications

Series S800S / S800S-UC
Order code 2CCF019999R0001
Product group S800 / S800P / S750 MCB
Product type High-performance miniature circuit breaker (MCB)
Rated current 0.5 A
Tripping characteristic UC-K / Type K
Number of poles 2
Protected poles 2
Rated voltage 500 V DC
Ultimate short-circuit breaking capacity (Icu) 50 kA at 500 V DC
Rated insulation voltage (Ui) 1500 V
Rated impulse withstand voltage (Uimp) 8 kV
Standard IEC/EN 60947-2
Application Direct-current circuit protection
Protection rating IP20
Operating ambient temperature -40 to 70 °C
Power loss 4 W
Width 3 modules
Installation depth 82.5 mm
Weight approx. 0.49 kg
GTIN / EAN 7612271500658

Frequently Asked Questions

What is the ABB S802S-UCK0.5 used for?

The S802S-UCK0.5 protects direct-current electrical circuits against overloads and short circuits and is particularly suited to demanding low-current commercial and industrial applications requiring high breaking capacity.

What is the rated current of the S802S-UCK0.5?

The ABB S802S-UCK0.5 has a rated current of 0.5 A.

What is the breaking capacity of the S802S-UCK0.5?

The S802S-UCK0.5 has an ultimate short-circuit breaking capacity of 50 kA at 500 V DC, providing high fault-current protection for demanding DC installations.

What does the Type K characteristic of the S802S-UCK0.5 mean?

The UC-K / Type K characteristic is suitable for circuits where functional starting or inrush currents can occur, including applications with inductive loads, while still providing overload and short-circuit protection.

What is the ABB order code for the S802S-UCK0.5?

The ABB order code for the S802S-UCK0.5 is 2CCF019999R0001.

Trusted High-Performance Protection from ABB

ABB S800 high-performance circuit breakers provide reliable overload and short-circuit protection for demanding commercial and industrial installations, with specialised S800S-UC variants engineered for direct-current circuit applications.