2CCF019005R0001 ABB S801HV-K6 MCB 4 kA 1P Type K 6 A

2CCF019005R0001 ABB S801HV-K6 MCB 4 kA 1P Type K 6 A

ABB S801HV-K6 is a 6 A single-pole Type K miniature circuit breaker with 4 kA breaking capacity for reliable overload and short-circuit protection in compatible electrical systems.

SKU: 2CCF019005R0001Alt SKU: S801HVK6MPN: 2CCF019005R0001
Price
List Price £336.61 ex VAT
Your Price (ex VAT) Save 35%
£218.80 35% OFF
You save £117.81 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £218.80
Trade pricing is personalised to your account

Manufacturer Lead Time

£218.80

Why Choose the ABB S801HV-K6 Miniature Circuit Breaker?

The ABB S801HV-K6 is a high-performance single-pole miniature circuit breaker (MCB) designed to provide reliable overcurrent protection in demanding electrical installations. Part of ABB's S800 high-performance circuit protection range, this model combines a Type K tripping characteristic with a rated current of 6 A.

Designed to protect electrical circuits against overload and short-circuit conditions, the S801HV-K6 provides single-pole protection in a compact modular format. Its Type K characteristic makes it particularly suitable for circuits supplying inductive equipment where comparatively high starting or inrush currents can occur during normal operation.

With a 6 A rated current, single-pole configuration and 4 kA short-circuit breaking capacity, the S801HV-K6 provides dependable protection for compatible control, auxiliary and equipment circuits. ABB order code 2CCF019005R0001 uniquely identifies this S801HV Type K configuration.

Key Advantages

  • Reliable overload and short-circuit protection for electrical circuits.
  • 6 A rated current for compatible control, auxiliary and equipment applications.
  • Single-pole (1P) configuration for individual circuit protection.
  • Type K tripping characteristic suited to inductive loads with elevated starting currents.
  • 4 kA short-circuit breaking capacity.
  • Part of ABB's established S800 high-performance circuit protection range.
  • Compact modular construction supports integration into professional electrical assemblies.

Key Features

  • ABB S801HV series miniature circuit breaker.
  • 6 A rated current.
  • Single pole (1P).
  • Type K tripping characteristic.
  • 4 kA short-circuit breaking capacity.
  • Protection against overload and short-circuit conditions.
  • Type K characteristic suited to inductive circuits with elevated inrush currents.
  • High-performance modular circuit-protection design.
  • ABB order code 2CCF019005R0001.

Reliable Circuit Protection for Inductive Loads

Miniature circuit breakers such as the ABB S801HV-K6 automatically interrupt an electrical circuit when excessive current results from an overload or short circuit. This helps protect conductors and connected equipment while providing a resettable alternative to one-time overcurrent protection devices.

The S801HV-K6 combines a compact single-pole arrangement with a Type K tripping characteristic. This characteristic is particularly useful for inductive equipment that can draw elevated current during starting, while the breaker continues to provide the required overload and short-circuit protection for the circuit.

Typical Applications

  • Industrial electrical distribution systems.
  • Control and auxiliary circuits.
  • Inductive loads with elevated starting currents.
  • Machine and automation electrical systems.
  • Electrical control panels and switchgear.
  • Equipment protection and power-distribution assemblies.

Technical Specifications

Series S801HV
ABB order code 2CCF019005R0001
Product type Miniature circuit breaker (MCB)
Number of poles 1
Rated current 6 A
Tripping characteristic Type K
Short-circuit breaking capacity 4 kA
Protection function Overload and short-circuit protection
Product group S800 / S800P / S750 MCB

Frequently Asked Questions

What is the ABB S801HV-K6 used for?

The ABB S801HV-K6 is a single-pole miniature circuit breaker designed to protect compatible electrical circuits against overload and short-circuit currents.

What is the rated current of the S801HV-K6?

The ABB S801HV-K6 has a rated current of 6 A.

What does the Type K characteristic mean?

The Type K tripping characteristic is suited to circuits containing inductive loads that can produce relatively high starting or inrush currents while still requiring effective overload and short-circuit protection.

What is the breaking capacity of the ABB S801HV-K6?

The S801HV-K6 has a specified short-circuit breaking capacity of 4 kA.

What is the ABB order code for the S801HV-K6?

The ABB order code for the S801HV-K6 is 2CCF019005R0001.

Trusted ABB Protection for Professional Electrical Systems

ABB S800 family miniature circuit breakers provide dependable modular overcurrent protection for professional electrical installations, supporting industrial control, distribution and equipment-protection applications.