ABB MCCB 1sda054213r1-t4h 250 tma 160-1600 3 pole

ABB MCCB 1sda054213r1-t4h 250 tma 160-1600 3 pole

ABB 1SDA054213R1 SACE Tmax T4H 250 three-pole fixed moulded case circuit breaker with 160 A thermal magnetic TMA release and front terminals for industrial power distribution.

SKU: 1SDA054213R1Alt SKU: T4H 250 TMA 160-1600 3p F FMPN: 1SDA054213R1
Price on application Contact us for pricing and availability.
Call 01708 343600

Why Choose the ABB 1SDA054213R1 Tmax T4H Moulded Case Circuit Breaker?

The ABB 1SDA054213R1 is a high-performance Tmax T4H moulded case circuit breaker (MCCB) designed to provide reliable protection against overloads and short circuits in industrial and commercial low voltage electrical systems. As part of the proven ABB SACE Tmax T series, it delivers dependable circuit protection, high breaking capacity and compact installation for demanding power distribution applications.

This model features a 250 A frame size with a 160 A thermal magnetic TMA release. Its fixed three-pole configuration and front terminal connections make it suitable for switchboards, distribution panels, motor control centres and OEM machinery where robust protection and long service life are essential.

With a rated operational voltage up to 690 V AC, high short-circuit performance level and compliance with IEC 60947, the ABB 1SDA054213R1 is a dependable choice for industrial engineers, panel builders and electrical contractors.

Key Advantages

  • High-performance ABB SACE Tmax T4H moulded case circuit breaker.
  • 160 A thermal magnetic TMA trip unit within a 250 A frame.
  • Three-pole fixed construction for industrial power distribution.
  • High breaking capacity for demanding fault conditions.
  • Compact panel-mounted design with front terminal connections.
  • Reliable overload and short-circuit protection.

Key Features

  • Manufacturer: ABB.
  • Series: SACE Tmax T.
  • Model: T4H 250 TMA 160-1600 3P F F.
  • Product ID: 1SDA054213R1.
  • 160 A rated current.
  • 250 A frame size.
  • Thermal magnetic TMA release.
  • Fixed three-pole configuration.
  • Front terminal connections.
  • Rated operational voltage up to 690 V AC.

Reliable Protection for Industrial Power Distribution

The ABB Tmax T4H range is engineered to protect low voltage electrical systems by rapidly disconnecting circuits during overload or short-circuit conditions. Its high breaking capacity makes it suitable for demanding industrial environments where safety, reliability and continuity of service are critical.

The integrated thermal magnetic TMA trip unit provides dependable overload protection together with fast magnetic tripping during fault conditions, helping to protect connected equipment, cables and power distribution infrastructure.

Typical Applications

  • Industrial switchboards.
  • Power distribution systems.
  • Motor control centres.
  • OEM machinery and automation equipment.
  • Commercial electrical installations.
  • Manufacturing and processing facilities.

Technical Specifications

Tick the specs you need, then view products that match.

Current 160 A
Phase Three Phase
Poles 3-pole
Device Type MCCB
Breaking Capacity 100 kA
Trip Unit Thermal-magnetic
Manufacturer ABB
Series SACE Tmax T
Product ID 1SDA054213R1
EAN 8015644553135
Extended product type T4H 250 TMA 160-1600 3P F F
Product type Moulded Case Circuit Breaker (MCCB)
Frame size T4H 250
Rated current (In) 160 A
Rated uninterrupted current (Iu) 250 A
Release TMA
Release type Thermal Magnetic (TM)
Magnetic setting range 800-1600 A
Number of poles 3
Rated operational voltage 690 V AC / 750 V DC
Rated insulation voltage (Ui) 1000 V
Rated impulse withstand voltage (Uimp) 8 kV
Rated ultimate short-circuit breaking capacity (Icu) 100 kA at 230 V AC, 70 kA at 415 V AC, 40 kA at 690 V AC
Rated service short-circuit breaking capacity (Ics) 100 kA at 230 V AC, 70 kA at 415 V AC, 40 kA at 690 V AC
Short-circuit performance level H
Terminal type Front terminals
Mounting Fixed
Electrical durability 8,000 cycles
Mechanical durability 20,000 cycles
Dimensions (H × W × D) 205 × 105 × 103.5 mm
Weight Approx. 2.35 kg
Standards IEC 60947

Frequently Asked Questions

What is the ABB 1SDA054213R1 used for?

It provides overload and short-circuit protection for industrial and commercial low voltage electrical distribution systems.

What current rating does this breaker provide?

This model features a 160 A thermal magnetic TMA trip unit within a 250 A Tmax T4H frame.

How many poles does the ABB 1SDA054213R1 have?

The ABB 1SDA054213R1 is supplied as a fixed three-pole moulded case circuit breaker.

What connection type does this MCCB use?

This breaker uses front terminal connections, making it suitable for installation in switchboards, control panels and power distribution assemblies.

Where is this MCCB typically installed?

It is commonly installed in industrial switchboards, motor control centres, distribution panels, OEM machinery and commercial electrical systems.

Trusted by Electrical Professionals Worldwide

ABB SACE Tmax moulded case circuit breakers are trusted worldwide by electrical engineers, panel builders and OEM manufacturers for dependable protection, high fault interruption performance and long-term operational reliability.