2CTB815708R2300 ABB OVR T2 4L 80-275s P QS Surge Protective Device

2CTB815708R2300 ABB OVR T2 4L 80-275s P QS Surge Protective Device

ABB OVR T2 4L 80-275s P QS is a four-pole pluggable Type 2 surge protective device for 230/400 V AC TN-S systems, with Safety Reserve technology, 20 kA nominal discharge current, 80 kA maximum discharge current and 275 V AC maximum continuous operating voltage.

SKU: 2CTB815708R2300MPN: 2CTB815708R2300
Price
List Price £458.42 ex VAT
Your Price (ex VAT) Save 25%
£343.82 25% OFF
You save £114.61 per unit
Manufacturer Lead Time Estimated Delivery 10 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £343.82
Trade pricing is personalised to your account

Manufacturer Lead Time

£343.82

Why Choose the ABB OVR T2 4L 80-275s P QS Surge Protective Device?

The ABB OVR T2 4L 80-275s P QS, order code 2CTB815708R2300, is a high-capacity Type 2 surge protective device (SPD) designed for three-phase plus neutral 230/400 V AC TN-S electrical systems. Its four protected lines provide coordinated surge protection for L1, L2, L3 and N conductors, helping protect distribution equipment and connected loads against transient overvoltages caused by indirect lightning effects and electrical switching events.

Designed for demanding low-voltage installations, the OVR T2 4L 80-275s P QS has a maximum continuous operating voltage Uc of 275 V AC. It provides a nominal discharge current In of 20 kA per protected line and a maximum discharge current Imax of 80 kA using the 8/20 µs waveform, together with an impulse-current capability Iimp of 6.25 kA using the 10/350 µs waveform and a voltage protection level Up of 1.4 kV.

ABB's Safety Reserve technology supports preventive maintenance and increased protection availability, while QuickSafe technology provides dependable thermal disconnection at end of life. The four-pole device uses pluggable protection cartridges with individual mechanical status indication, allowing straightforward inspection and cartridge replacement without replacing the complete SPD assembly.

Key Advantages

  • High-capacity Type 2 / Class II surge protection for three-phase plus neutral TN-S systems.
  • Four protected lines provide surge protection across L1, L2, L3 and N.
  • 80 kA maximum discharge current using the 8/20 µs waveform.
  • 20 kA nominal discharge current per protected line.
  • 6.25 kA impulse-current capability using the 10/350 µs waveform.
  • 1.4 kV voltage protection level helps limit transient stress on downstream equipment.
  • Safety Reserve technology supports preventive maintenance and protection continuity.
  • ABB QuickSafe technology provides reliable thermal disconnection.
  • Pluggable cartridges simplify servicing and replacement.
  • Individual mechanical status indicators allow quick visual inspection of each protection module.
  • 100 kA rated service short-circuit breaking capacity supports demanding distribution applications.

Key Features

  • ABB OVR T2 QuickSafe series.
  • Type 2 / Class II surge protective device.
  • Four-pole, four-line configuration.
  • Designed for TN-S low-voltage distribution systems.
  • 230/400 V AC rated system voltage.
  • 275 V AC maximum continuous operating voltage Uc.
  • 20 kA nominal discharge current In.
  • 80 kA maximum discharge current Imax.
  • 6.25 kA impulse current Iimp.
  • 1.4 kV voltage protection level Up.
  • Safety Reserve preventive-maintenance function.
  • Varistor-based protection technology.
  • Pluggable protection cartridges.
  • Mechanical status indication for each arrester module.
  • No TS auxiliary remote-signalling contact.

High-Capacity Four-Line Protection for TN-S Networks

Type 2 SPDs are designed to divert transient currents associated with indirect lightning effects and electrical switching before damaging overvoltages reach downstream equipment. The ABB OVR T2 4L 80-275s P QS combines four protected lines with an 80 kA maximum discharge-current rating and 1.4 kV voltage protection level, making it particularly suitable for demanding three-phase plus neutral TN-S distribution systems.

The Safety Reserve design supports preventive maintenance and continued protection availability, while ABB QuickSafe technology provides dependable thermal disconnection. Each protection module is pluggable and incorporates mechanical condition indication, allowing maintenance personnel to identify an affected module and replace its cartridge without unnecessarily replacing the complete four-pole SPD assembly.

Typical Applications

  • Three-phase plus neutral 230/400 V AC TN-S installations.
  • Main low-voltage distribution switchboards.
  • Intermediate and sub-distribution boards.
  • Commercial building electrical systems.
  • Industrial and manufacturing facilities.
  • Process-control and automation installations.
  • Protection of sensitive electrical and electronic equipment.
  • Installations exposed to significant transient surge currents.
  • Applications requiring high-capacity four-line Type 2 surge protection.
  • Installations where Safety Reserve preventive-maintenance functionality is beneficial.

Technical Specifications

Tick the specs you need, then view products that match.

Remote Signal No
SPD Type Type 2
Poles 4-pole
Earthing System TN-S
Device Type Surge protection device
Impulse Current Iimp (kA) 6.25 kA
Series OVR T2 QuickSafe
ABB order code 2CTB815708R2300
EAN / GTIN 3660308525529
Product group Surge Protection Devices
Product type Type 2 surge protective device
SPD classification Type 2 / Class II
Standards IEC 61643-11 / EN 61643-11
Protection technology Varistor
Low-voltage distribution system TN-S
Number of poles 4
Number of protected lines 4
Rated system voltage 230 / 400 V AC
Maximum continuous operating voltage Uc 275 V AC
Impulse current Iimp (10/350 µs) 6.25 kA
Nominal discharge current In (8/20 µs) 20 kA
Maximum discharge current Imax (8/20 µs) 80 kA
Total maximum discharge-current capability 320 kA
Voltage protection level Up 1.4 kV
Rated service short-circuit breaking capacity Ics 100 kA
Safety Reserve Yes
Preventive maintenance function Yes
QuickSafe technology Yes
Status indication Mechanical indicator on each protection module
Remote signalling No
Construction Pluggable
Replacement cartridge OVR T2 80-275s C QS
Replacement cartridge order code 2CTB815708R2600
Degree of protection IP20
Operating temperature -40 to +80 °C
Mounting type DIN rail
Module width 4 modules

Frequently Asked Questions

What is the ABB OVR T2 4L 80-275s P QS used for?

It is a Type 2 surge protective device designed for three-phase plus neutral 230/400 V AC TN-S systems, providing four-line protection against transient overvoltages caused by indirect lightning effects and electrical switching events.

What are the discharge-current ratings of the OVR T2 4L 80-275s P QS?

The device provides a nominal discharge current In of 20 kA and a maximum discharge current Imax of 80 kA using the 8/20 µs waveform, together with a 6.25 kA impulse-current capability using the 10/350 µs waveform.

What does the “s” mean in OVR T2 4L 80-275s?

The “s” identifies ABB's Safety Reserve version. Safety Reserve technology supports preventive maintenance and helps maintain a level of surge protection when the primary protection stage reaches end of life.

Does the OVR T2 4L 80-275s P QS have remote signalling?

No. ABB order code 2CTB815708R2300 is the P QS version without the TS auxiliary remote-signalling contact. Local condition information is provided by the mechanical status indicators on the protection modules.

Can the protection cartridges be replaced?

Yes. The OVR T2 4L 80-275s P QS uses pluggable protection cartridges. The compatible ABB OVR T2 80-275s C QS replacement cartridge has order code 2CTB815708R2600.

Trusted ABB Surge Protection Technology

ABB OVR Type 2 surge protective devices combine high surge-current capability, QuickSafe technology and pluggable construction, with the OVR T2 4L 80-275s P QS delivering four-line protection, Safety Reserve functionality and up to 80 kA maximum discharge current per protection path for demanding three-phase plus neutral TN-S installations.