2CTB803871R1300 ABB OVR T2-T3 20-440 P TS QS Surge Protective Device

2CTB803871R1300 ABB OVR T2-T3 20-440 P TS QS Surge Protective Device

ABB 2CTB803871R1300 OVR T2-T3 20-440 P TS QS is a single-pole pluggable QuickSafe Type 2 and Type 3 surge protective device with 440 V AC maximum continuous operating voltage, 20 kA maximum discharge current, 5 kA nominal discharge current and remote signalling.

SKU: 2CTB803871R1300MPN: 2CTB803871R1300
Price
List Price £118.98 ex VAT
Your Price (ex VAT) Save 25%
£89.24 25% OFF
You save £29.75 per unit
Manufacturer Lead Time Estimated Delivery 10 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £89.24
Trade pricing is personalised to your account

Manufacturer Lead Time

£89.24

Why Choose the ABB OVR T2-T3 20-440 P TS QS Surge Protective Device?

The ABB OVR T2-T3 20-440 P TS QS 2CTB803871R1300 is a combined Type 2 and Type 3 surge protective device (SPD) designed to protect low-voltage electrical installations and sensitive downstream equipment against transient overvoltages. Part of ABB's OVR QuickSafe range, this single-pole SPD combines Type 2 surge-current handling with Type 3 protection characteristics in a compact DIN-rail format.

Designed for 400 V AC nominal applications, the OVR T2-T3 20-440 P TS QS has a maximum continuous operating voltage Uc of 440 V AC. It provides a maximum discharge current Imax of 20 kA and a nominal discharge current In of 5 kA using an 8/20 µs waveform, together with a voltage protection level Up of 1.4 kV.

The QuickSafe (QS) pluggable design enables convenient cartridge replacement, while the TS configuration provides remote signalling through integrated auxiliary contacts. A visual status indicator provides local condition information, making the 2CTB803871R1300 particularly suitable for distribution boards and installations where both local and remote monitoring of surge protection status are valuable.

Key Advantages

  • Combined Type 2 and Type 3 surge protection in a compact modular device.
  • 20 kA maximum discharge current (Imax) for transient surge-current handling.
  • 5 kA nominal discharge current (In) using an 8/20 µs waveform.
  • 1.4 kV voltage protection level Up helps limit transient voltage reaching downstream equipment.
  • TS remote signalling enables integration with compatible monitoring systems.
  • QuickSafe pluggable construction supports straightforward inspection and cartridge replacement.

Key Features

  • ABB OVR T2-T3 QuickSafe range.
  • Combined Type 2 + Type 3 surge protective device.
  • Single protected pole.
  • 400 V AC nominal voltage.
  • 440 V AC maximum continuous operating voltage Uc.
  • 20 kA maximum discharge current Imax.
  • 5 kA nominal discharge current In.
  • 1.4 kV voltage protection level Up.
  • Visual status indication for local condition checking.
  • Remote signalling contacts with 1 NO + 1 NC configuration.

Combined Type 2 and Type 3 QuickSafe Surge Protection

Combined Type 2 and Type 3 SPDs provide surge-current handling for distribution-level protection while also offering a low voltage protection level suitable for protecting sensitive downstream equipment. They can be installed in distribution boards and close to terminal equipment as part of a coordinated surge protection concept.

The ABB OVR T2-T3 20-440 P TS QS combines a 20 kA Imax, 5 kA In and 1.4 kV Up in a compact 17.8 mm module. QuickSafe pluggable construction, visual status indication and TS remote signalling make it particularly practical where straightforward maintenance and continuous SPD condition monitoring are required.

Typical Applications

  • Main and intermediate electrical distribution boards.
  • Protection close to sensitive terminal equipment.
  • Commercial building electrical installations.
  • Industrial control and automation panels.
  • Residential and building-services distribution systems.
  • Protection of sensitive electronic and control equipment.
  • Installations requiring remote surge protector status monitoring.

Technical Specifications

Tick the specs you need, then view products that match.

Remote Signal Yes
SPD Type Type 2+3
Device Type Surge protection device
Impulse Current Iimp (kA) 2 kA
Series OVR T2-T3 QuickSafe
Order code 2CTB803871R1300
Product group Surge Protection Devices
Product type Combined Type 2 + Type 3 surge protective device
Number of protected poles 1
Nominal voltage Un 400 V AC
Maximum continuous operating voltage Uc 440 V AC
Maximum discharge current Imax (8/20 µs) 20 kA
Nominal discharge current In (8/20 µs) 5 kA
Impulse current Iimp (10/350 µs) 2 kA
Voltage protection level Up 1.4 kV
Short-circuit withstand rating 100 kA
Degree of protection IP20
Status indicator Yes
Construction Pluggable
Technology QuickSafe (QS)
Remote signalling Yes
Auxiliary contacts 1 NO + 1 NC
Replacement cartridge OVR T2-T3 20-440 C QS, 2CTB803876R0600
Compatible distribution systems TT / TN-C / TN-S / IT
Mounting DIN rail
Maximum operating altitude 5000 m
Dimensions (H × W × D) 95 × 17.8 × 58 mm
Net weight 0.12 kg
Standards IEC 61643-11 / EN 61643-11

Frequently Asked Questions

What is the ABB OVR T2-T3 20-440 P TS QS?

The ABB 2CTB803871R1300 is a single-pole combined Type 2 and Type 3 surge protective device with QuickSafe pluggable construction, visual status indication and remote signalling.

What are the discharge current ratings of the OVR T2-T3 20-440 P TS QS?

The device has a maximum discharge current Imax of 20 kA and a nominal discharge current In of 5 kA, based on an 8/20 µs waveform.

What is the maximum continuous operating voltage of 2CTB803871R1300?

The ABB 2CTB803871R1300 has a maximum continuous operating voltage Uc of 440 V AC and a nominal voltage of 400 V AC.

Can the cartridge in the ABB OVR T2-T3 20-440 P TS QS be replaced?

Yes. Its QuickSafe pluggable construction allows cartridge replacement, with the ABB OVR T2-T3 20-440 C QS, order code 2CTB803876R0600, specified as the corresponding replacement cartridge.

Does the ABB OVR T2-T3 20-440 P TS QS provide remote signalling?

Yes. The TS configuration provides remote signalling with one normally open and one normally closed auxiliary contact, complementing the device's local visual status indicator.

Trusted QuickSafe Surge Protection from ABB

ABB OVR QuickSafe surge protective devices provide electrical designers, installers and maintenance professionals with compact protection against transient overvoltages, combining pluggable construction, clear status indication and remote signalling for practical installation and maintenance.