2CSR273001R1205 ABB DS203MACB200.03 DS203 M AC-B20/0.03 RCBO 20 A 3P AC 30 mA 10 kA

2CSR273001R1205 ABB DS203MACB200.03 DS203 M AC-B20/0.03 RCBO 20 A 3P AC 30 mA 10 kA

ABB DS203MACB200.03 DS203 M AC-B20/0.03 is a 20 A 3-pole Type AC RCBO with 30 mA residual current sensitivity, B tripping characteristic and 10 kA short-circuit capacity for three-phase electrical circuit protection.

SKU: 2CSR273001R1205Alt SKU: DS203MACB200.03MPN: 2CSR273001R1205
Price
List Price £318.39 ex VAT
Your Price (ex VAT) Save 35%
£206.95 35% OFF
You save £111.44 per unit
Manufacturer Lead Time Estimated Delivery 9 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £206.95
Trade pricing is personalised to your account

Manufacturer Lead Time

£206.95

Why Choose the ABB DS203MACB200.03 RCBO?

The ABB DS203MACB200.03, manufacturer type code DS203 M AC-B20/0.03, is a high-performance 3-pole residual current circuit breaker with overcurrent protection (RCBO) designed to provide combined protection against overloads, short circuits and earth fault currents. As part of the ABB DS200 M RCBO series, it combines overcurrent and residual current protection in a single modular device for commercial and industrial electrical distribution systems.

This Type AC RCBO is designed to detect sinusoidal alternating residual currents. Its Type B tripping characteristic provides sensitive magnetic operation suitable for circuits with relatively low inrush currents, while the 30 mA residual current sensitivity provides additional protection against electric shock and helps protect installations against earth leakage faults.

With a rated current of 20 A, a 3-pole configuration and a 10 kA rated short-circuit capacity, the DS203 M AC-B20/0.03 provides coordinated protection for three-phase electrical circuits. Its compact DIN-rail format enables straightforward integration into modular distribution boards and industrial electrical panels.

Key Advantages

  • Combined residual current, overload and short-circuit protection in one RCBO.
  • 20 A rated current for protected three-phase circuits.
  • 30 mA residual current sensitivity for additional protection against electric shock.
  • Type AC residual current protection for sinusoidal alternating earth fault currents.
  • Type B tripping characteristic suitable for circuits with relatively low inrush currents.
  • 10 kA short-circuit capacity for robust electrical circuit protection.
  • 3-pole configuration for three-phase applications.
  • Compact modular construction simplifies installation in electrical distribution systems.

Key Features

  • ABB DS200 M series RCBO.
  • 20 A rated current.
  • 3-pole configuration.
  • 30 mA rated residual operating current.
  • Type AC residual current characteristic.
  • B tripping characteristic.
  • 10 kA rated short-circuit capacity.
  • Combined protection against overload, short circuit and residual current faults.
  • Detection of sinusoidal alternating residual currents.
  • DIN-rail mounting for modular electrical distribution systems.
  • Integrated test facility for routine verification of residual current protection.

Reliable Protection for Three-Phase Electrical Circuits

An RCBO combines overcurrent and residual current protection in one device. The ABB DS203 M AC-B20/0.03 therefore protects electrical circuits against excessive current caused by overloads and short circuits while also detecting potentially hazardous sinusoidal alternating leakage currents to earth.

The Type AC residual current characteristic is designed for circuits where sinusoidal alternating residual currents are expected. Combined with its 30 mA sensitivity, B tripping characteristic and three protected poles, the DS203 M AC-B20/0.03 provides dependable coordinated protection for suitable three-phase electrical installations.

Typical Applications

  • Three-phase electrical distribution circuits.
  • Commercial electrical distribution boards.
  • Industrial control and distribution panels.
  • Final circuits requiring combined overcurrent and residual current protection.
  • Building services and electrical infrastructure.
  • DIN-rail-mounted modular distribution systems.

Technical Specifications

Series DS200 M
Product range System pro M compact
ABB type code DS203 M AC-B20/0.03
ABB order code 2CSR273001R1205
Product type Residual current circuit breaker with overcurrent protection (RCBO)
Rated current 20 A
Number of poles 3
Residual current type Type AC
Rated residual current 30 mA
Tripping characteristic B
Rated short-circuit capacity 10 kA
Rated voltage 400 V AC
Frequency 50 / 60 Hz
Mounting type DIN rail

Frequently Asked Questions

What is the ABB DS203MACB200.03 used for?

The ABB DS203MACB200.03 is a 3-pole RCBO used to protect electrical circuits against overloads, short circuits and sinusoidal alternating residual earth fault currents.

What is the current rating of the DS203 M AC-B20/0.03?

The RCBO has a rated current of 20 A and uses a Type B tripping characteristic.

What residual current sensitivity does this RCBO provide?

The DS203 M AC-B20/0.03 has a rated residual operating current of 30 mA, providing additional protection against electric shock and protection against earth leakage faults.

What does Type AC residual current protection mean?

Type AC protection is designed to detect sinusoidal alternating residual currents that can occur in conventional AC electrical circuits.

What is the breaking capacity of the ABB DS203 M AC-B20/0.03?

The DS203 M AC-B20/0.03 has a rated short-circuit capacity of 10 kA, providing robust overcurrent protection for suitable electrical distribution circuits.

Trusted ABB Circuit Protection

ABB DS200 series RCBOs combine residual current, overload and short-circuit protection in a compact modular format, supporting dependable electrical distribution in commercial and industrial installations.