2CSR256140R3104 ABB DS203NCC10A300 DS203NC C10 A300 3P+N Type A RCBO 10A 300mA

2CSR256140R3104 ABB DS203NCC10A300 DS203NC C10 A300 3P+N Type A RCBO 10A 300mA

ABB DS203NCC10A300 is a 3P+N Type A RCBO with 10 A rated current, C tripping characteristic, 300 mA residual-current sensitivity and 6 kA breaking capacity for three-phase circuit protection.

SKU: 2CSR256140R3104Alt SKU: DS203NCC10A300MPN: 2CSR256140R3104
Price
List Price £253.65 ex VAT
Your Price (ex VAT) Save 35%
£164.87 35% OFF
You save £88.78 per unit
Manufacturer Lead Time Estimated Delivery 8 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £164.87
Trade pricing is personalised to your account

Manufacturer Lead Time

£164.87

Why Choose the ABB DS203NCC10A300 RCBO?

The ABB DS203NCC10A300 is a compact and reliable 3P+N residual current circuit breaker with overcurrent protection (RCBO) designed to protect three-phase electrical circuits against overloads, short circuits and residual earth-fault currents. As part of the ABB DS203NC series, it combines residual-current and overcurrent protection within a space-saving four-module device for modern electrical distribution systems.

This RCBO features a 10 A rated current, C tripping characteristic and Type A residual-current detection. Type A protection detects sinusoidal AC residual currents as well as pulsating DC residual currents, making the DS203NCC10A300 suitable for a wide range of commercial and industrial circuits containing modern electronic loads.

With a rated residual operating current of 300 mA, a rated voltage of 400–415 V AC and a rated short-circuit breaking capacity of 6 kA according to EN/IEC 61009, the DS203NCC10A300 provides coordinated circuit and earth-fault protection. Its compact 3P+N four-module construction incorporates three protected poles and a switched neutral for efficient installation in three-phase distribution boards.

Key Advantages

  • Combined residual-current, overload and short-circuit protection in one device.
  • 3P+N configuration for three-phase circuits with neutral.
  • 10 A rated current with C tripping characteristic.
  • 300 mA Type A residual-current sensitivity.
  • 6 kA rated short-circuit breaking capacity according to EN/IEC 61009.
  • Compact four-module design helps minimise distribution-board space.
  • Integrated earth-fault trip indication assists troubleshooting and maintenance.
  • DIN-rail format enables straightforward installation in modular distribution equipment.

Key Features

  • ABB DS203NC RCBO series.
  • 3P+N configuration with three protected poles.
  • 10 A rated current.
  • C tripping characteristic.
  • Type A residual-current detection.
  • 300 mA rated residual operating current.
  • 400–415 V AC rated voltage.
  • 50/60 Hz rated frequency.
  • 6 kA Icn breaking capacity according to EN/IEC 61009.
  • 10 kA ultimate short-circuit breaking capacity according to IEC 60947-2.
  • IP2X protection rating.
  • Compact four-module DIN-rail construction.

Reliable Protection for Three-Phase Electrical Circuits

RCBOs combine the functions of a miniature circuit breaker and residual-current device in a single protective unit. The ABB DS203NCC10A300 monitors the circuit for overload and short-circuit conditions while simultaneously detecting residual currents to earth, providing coordinated protection for conductors, connected equipment and electrical installations.

The ABB DS203NC range is engineered to provide this combined protection in only four DIN modules. The DS203NCC10A300 also incorporates earth-fault trip indication, helping operators distinguish residual-current operation during troubleshooting and reducing the time required to identify the cause of a circuit interruption.

Typical Applications

  • Three-phase commercial electrical distribution systems.
  • Industrial electrical distribution boards.
  • Machinery and automation power circuits.
  • Three-phase circuits requiring Type A residual-current protection.
  • Circuits requiring combined overload, short-circuit and earth-fault protection.
  • Compact switchboards and modular DIN-rail distribution equipment.

Technical Specifications

Series DS203NC
SKU DS203NCC10A300
ABB order code 2CSR256140R3104
EAN 8012542839729
Product type Residual current circuit breaker with overcurrent protection (RCBO)
Number of poles 3P+N / 4 poles
Protected poles 3
Rated current 10 A
Tripping characteristic C
Residual-current type Type A
Rated residual operating current 300 mA
Rated voltage 400–415 V AC
Frequency 50/60 Hz
Rated short-circuit breaking capacity Icn 6 kA
Rated ultimate short-circuit breaking capacity Icu 10 kA
Rated service short-circuit breaking capacity Ics 6 kA
Rated insulation voltage Ui 500 V
Rated impulse withstand voltage Uimp 4 kV
Energy limiting class 3
Overvoltage category III
Pollution degree 2
Protection rating IP2X
Operating temperature -25 to +55 °C
Terminal capacity Up to 25 mm² conductor
Busbar connection capacity 10 mm²
Mounting type DIN rail
Width 4 modules / 71 mm
Built-in depth 69 mm
Weight approx. 0.48 kg
Standards IEC/EN 61009-1, IEC/EN 61009-2-1

Frequently Asked Questions

What is the ABB DS203NCC10A300 used for?

The ABB DS203NCC10A300 is a 3P+N RCBO designed to protect three-phase electrical circuits against overloads, short circuits and residual earth-fault currents.

What is the rated current and trip characteristic of the DS203NCC10A300?

The RCBO has a rated current of 10 A and uses a C tripping characteristic.

What residual-current protection does this RCBO provide?

The DS203NCC10A300 provides Type A residual-current protection with a rated residual operating current of 300 mA.

What is the breaking capacity of the ABB DS203NCC10A300?

The device has a rated short-circuit breaking capacity Icn of 6 kA according to EN/IEC 61009 and an ultimate short-circuit breaking capacity of 10 kA according to IEC 60947-2.

How much space does the DS203NCC10A300 require?

The DS203NCC10A300 occupies four DIN modules with a width of 71 mm, providing 3P+N residual-current and overcurrent protection in a compact installation footprint.

Trusted ABB Circuit Protection

ABB DS203NC RCBOs combine residual-current and overcurrent protection in a compact four-module format, providing dependable circuit protection for modern three-phase commercial and industrial electrical installations.