Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
ABB DS204AC400.03 is a four-pole Type A RCBO with a 40 A rated current, C tripping characteristic, 30 mA residual-current sensitivity and 6 kA breaking capacity for combined overload, short-circuit and earth leakage protection.
£290.93
The ABB DS204AC400.03, manufacturer type DS204 A-C40/0.03, is a high-performance four-pole Type A residual current circuit breaker with overcurrent protection (RCBO) designed to provide combined protection against overloads, short circuits and earth leakage faults in electrical installations. As part of the proven ABB DS200 series, it combines miniature circuit breaker and residual current protection functions in a single DIN-rail device.
This RCBO has a 40 A rated current, C tripping characteristic and 30 mA rated residual operating current. Its Type A residual-current detection provides protection against sinusoidal AC residual currents and pulsating DC residual currents, making it suitable for a broad range of residential, commercial and industrial circuits.
With four protected poles, a 400 V AC rated voltage and a 6 kA rated short-circuit breaking capacity according to IEC/EN 61009-1, the DS204 A-C40/0.03 provides dependable circuit and residual-current protection while helping simplify distribution-board design and installation.
An RCBO combines the functions of a miniature circuit breaker and a residual-current protective device. The ABB DS204 A-C40/0.03 therefore protects circuits against overload and short-circuit currents while also detecting earth leakage that can present an electric-shock or electrically initiated fire risk.
Its Type A characteristic enables detection of sinusoidal alternating and pulsating DC residual currents, while the C curve provides overcurrent protection suited to many general-purpose circuits and loads with moderate starting currents. The combined design reduces the number of separate protective devices required within an electrical distribution system.
| Series | DS200 |
|---|---|
| SKU | DS204AC400.03 |
| ABB order code | 2CSR254101R1404 |
| Product type | Residual current circuit breaker with overcurrent protection (RCBO) |
| Number of poles | 4 |
| Rated current | 40 A |
| Tripping characteristic | C |
| Residual-current type | Type A |
| Rated residual operating current | 30 mA |
| Rated voltage | 400 V AC |
| Rated short-circuit breaking capacity | 6 kA |
| Rated ultimate short-circuit breaking capacity | 10 kA at 400 V AC |
| Protection rating | IP20 |
| Mounting type | DIN rail |
| Operating temperature | -25 to +55 °C |
| Standards | IEC/EN 61009-1, IEC/EN 60947-2 |
| EAN | 8012542863205 |
The ABB DS204AC400.03 is a four-pole RCBO used to protect electrical circuits against overloads, short circuits and residual earth leakage currents.
The RCBO has a rated current of 40 A and uses a C tripping characteristic.
The DS204 A-C40/0.03 has a rated residual operating current of 30 mA, providing additional protection against electric shock.
Type A means the RCBO is designed to detect sinusoidal AC and pulsating DC residual currents, making it suitable for a wide range of modern electrical loads.
The RCBO has a rated short-circuit breaking capacity of 6 kA according to IEC/EN 61009-1 and an ultimate short-circuit breaking capacity of 10 kA at 400 V AC according to IEC/EN 60947-2.
ABB DS200 RCBOs provide integrated residual-current, overload and short-circuit protection for residential, commercial and industrial electrical installations, combining multiple protective functions in a compact modular device.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.