ABB F-ARI4Test A-40/0.3 is a 40 A 300 mA Type A 3P+N residual current circuit breaker with automatic testing, insulation checking and automatic reclosing.
£830.01
The ABB F-ARI4Test A-40/0.3 is an advanced Type A residual current circuit breaker (RCCB) with automatic testing and automatic reclosing designed to provide reliable residual-current protection while supporting continuity of electrical service. As part of the ABB F-ARI Test series, it combines automatic periodic testing with automatic reclosing functionality for electrical installations where dependable protection and service availability are important.
The F-ARI Test system automatically verifies the RCCB protective function without disconnecting the protected installation, helping reduce manual maintenance requirements while keeping connected equipment energised. Following a residual-current trip, the automatic reclosing system checks the insulation condition before attempting to restore the electrical supply, helping avoid reconnection while a persistent fault remains.
With a rated current of 40 A, a rated residual operating current of 300 mA and a 3P+N four-pole configuration, the F-ARI4Test A-40/0.3 provides Type A residual-current protection for three-phase circuits with neutral. Its DIN-rail design makes it suitable for commercial, industrial and infrastructure distribution boards where automatic protection management can improve system availability.
Residual current circuit breakers monitor the current balance in an electrical circuit and disconnect the supply when leakage current to earth exceeds the specified operating threshold. Type A RCCBs detect sinusoidal AC residual currents and pulsating DC residual currents, making them suitable for many modern electrical installations containing electronic loads.
The ABB F-ARI Test series extends conventional residual-current protection with automatic testing and reclosing functionality. Automatic testing helps verify the protective device without unnecessary interruption, while the reclosing system evaluates the insulation condition after a residual-current trip before restoring the supply.
| Series | F-ARI Test |
|---|---|
| ABB order code | 2CSF304131R3400 |
| Product type | RCCB with automatic test and automatic reclosing |
| Residual-current type | Type A |
| Rated current | 40 A |
| Rated residual operating current | 300 mA |
| Poles | 3P+N / 4 pole |
| Automatic test | Yes |
| Automatic reclosing | Yes |
| Insulation check before reclosing | Yes |
| Mounting type | DIN rail |
It provides Type A residual-current protection for three-phase circuits with neutral while adding automatic testing and automatic reclosing functionality.
The RCCB has a rated current of 40 A.
The F-ARI4Test A-40/0.3 has a rated residual operating current of 300 mA.
Yes. The F-ARI incorporates automatic reclosing and checks the insulation condition before attempting to restore the electrical supply.
It is a Type A RCCB, designed to detect sinusoidal AC residual currents and pulsating DC residual currents.
ABB F-ARI Test RCCBs combine automatic testing, insulation checking and automatic reclosing to support dependable residual-current protection and improved continuity of service in modern electrical installations.