ABB F-ARI4Test A-25/0.03 is a 25 A 30 mA Type A 3P+N residual current circuit breaker with automatic testing, insulation checking and automatic reclosing.
£798.40
The ABB F-ARI4Test A-25/0.03 is an advanced Type A residual current circuit breaker (RCCB) with automatic testing and automatic reclosing designed to provide dependable earth-leakage protection while maximising continuity of electrical service. As part of the ABB F-ARI Test series, it combines automatic periodic testing with intelligent reclosing after checking the insulation condition of the protected system.
The F-ARI system performs automatic RCCB testing without disconnecting the voltage from the installation, reducing routine manual intervention and helping maintain continuous operation. Following an earth-fault trip, its automatic reclosing function checks the insulation system before attempting to restore the supply, helping prevent reclosing when a permanent fault remains present.
With a rated current of 25 A, a rated residual operating current of 30 mA and a 3P+N four-pole configuration, the F-ARI4Test A-25/0.03 provides Type A residual-current protection for three-phase circuits with neutral. Its DIN-rail format makes it suitable for integration into commercial, industrial and infrastructure distribution boards where reliability and service continuity are important.
Residual current circuit breakers monitor electrical circuits for leakage current to earth and disconnect the supply when the residual current reaches the device's operating threshold. Type A RCCBs detect sinusoidal AC and pulsating DC residual currents, providing protection suitable for many modern electrical installations and electronic loads.
The ABB F-ARI Test series extends conventional RCCB functionality with automatic testing and reclosing. Periodic tests can be completed without interrupting service, while the reclosing process checks the insulation condition after an earth fault before restoring power, helping improve availability without compromising the protective function.
| Series | F-ARI Test |
|---|---|
| ABB order code | 2CSF304131R1250 |
| Product type | RCCB with automatic test and automatic reclosing |
| Residual-current type | Type A |
| Rated current | 25 A |
| Rated residual operating current | 30 mA |
| Poles | 3P+N / 4 pole |
| Automatic test | Yes, without supply interruption |
| Automatic reclosing | Yes |
| Insulation check before reclosing | Yes |
| Mounting type | DIN rail |
| Dimensions (H × W × D) | approx. 106 × 124.8 × 73.5 mm |
It provides Type A residual-current protection for three-phase circuits with neutral while adding automatic testing and automatic reclosing functionality.
The RCCB has a rated current of 25 A.
The F-ARI4Test A-25/0.03 has a rated residual operating current of 30 mA.
Yes. The F-ARI incorporates automatic reclosing and checks the insulation condition of the system before attempting to restore the electrical supply.
No. The F-ARI Test system performs its automatic RCCB test without disconnecting the voltage from the protected installation, helping maintain continuity of service.
ABB F-ARI Test RCCBs combine automatic testing, insulation fault checking and automatic reclosing to support dependable residual-current protection and improved continuity of service in modern electrical installations.