2CSF304130R3250 ABB F-ATI4Test A-25/0.3 RCCB 4 Pole 25 A 300 mA Auto Test

2CSF304130R3250 ABB F-ATI4Test A-25/0.3 RCCB 4 Pole 25 A 300 mA Auto Test

ABB F-ATI4Test A-25/0.3 is a 25 A 300 mA Type A 3P+N residual current circuit breaker with automatic testing without interruption of the electrical supply.

SKU: 2CSF304130R3250Alt SKU: FATI4TESTA250.3MPN: 2CSF304130R3250
Price
List Price £1,132.87 ex VAT
Your Price (ex VAT) Save 35%
£736.37 35% OFF
You save £396.50 per unit
Manufacturer Lead Time Estimated Delivery 9 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £736.37
Trade pricing is personalised to your account

Manufacturer Lead Time

£736.37

Why Choose the ABB F-ATI4Test A-25/0.3 RCCB?

The ABB F-ATI4Test A-25/0.3 is a reliable Type A residual current circuit breaker (RCCB) with automatic testing designed to provide residual-current protection while carrying out periodic functional tests without interrupting the electrical supply. As part of the advanced ABB F-ATI Test series, it combines residual-current protection with an automatic test function for installations where continuity of supply is important.

This RCCB automatically verifies its protective functionality without disconnecting downstream loads, helping reduce the need for manual testing while maintaining continuity for connected equipment. Its short-time delayed operating characteristic and automatic test capability make it particularly suitable for commercial, industrial and infrastructure electrical distribution systems.

With a rated current of 25 A, a rated residual operating current of 300 mA and a 3P+N four-pole configuration, the F-ATI4Test A-25/0.3 provides Type A residual-current detection for three-phase circuits with neutral. Its 7-module DIN-rail format enables straightforward installation in compatible electrical distribution boards.

Key Advantages

  • Integrated automatic RCCB testing without interruption of the electrical supply.
  • 25 A rated current for three-phase electrical circuits.
  • 300 mA rated residual operating current.
  • Type A residual-current detection for AC and pulsating DC residual currents.
  • 3P+N four-pole configuration for three-phase systems with neutral.
  • Short-time delayed operation helps improve selectivity against transient residual currents.

Key Features

  • ABB F-ATI Test automatic-test RCCB series.
  • 25 A rated current.
  • 300 mA residual-current sensitivity.
  • Type A residual-current characteristic.
  • 3P+N / four-pole configuration.
  • Automatic functional testing without disconnecting the protected circuit.
  • Short-time delayed residual-current operation.
  • 7-module DIN-rail design for distribution boards.

Automatic Residual-Current Protection

Residual current circuit breakers monitor the balance of current flowing through an electrical circuit and disconnect the supply when residual current exceeds the specified operating threshold. Type A RCCBs detect sinusoidal AC residual currents as well as pulsating DC residual currents, making them suitable for circuits supplying many modern electrical and electronic loads.

The ABB F-ATI Test series adds automatic functional testing without supply interruption. This allows the protective function to be checked while connected equipment remains energised, helping reduce maintenance intervention and making the series particularly useful where continuity of electrical service is required.

Typical Applications

  • Commercial and industrial electrical distribution boards.
  • Three-phase circuits requiring residual-current protection.
  • Building services and electrical infrastructure.
  • Installations where continuity of supply is important.
  • Unattended or remotely located electrical systems.
  • Circuits where automatic RCCB testing can reduce routine manual maintenance.

Technical Specifications

Series F-ATI Test
ABB order code 2CSF304130R3250
Product type RCCB with automatic test
Residual-current type Type A
Rated current 25 A
Rated residual operating current 300 mA
Poles 3P+N / 4 pole
Operating characteristic Short-time delayed
Automatic test Yes, without supply interruption
Module width 7 modules
Mounting type DIN rail
Dimensions (H × W × D) approx. 106 × 124.8 × 73.5 mm
Weight approx. 0.9 kg
EAN 8012542289456

Frequently Asked Questions

What is the ABB F-ATI4Test A-25/0.3 used for?

It provides Type A residual-current protection for three-phase circuits with neutral while automatically testing its protective functionality without interrupting the electrical supply.

What is the rated current of the F-ATI4Test A-25/0.3?

The RCCB has a rated current of 25 A.

What residual operating current does this RCCB provide?

The F-ATI4Test A-25/0.3 has a rated residual operating current of 300 mA.

Does the ABB F-ATI4Test interrupt the supply during its automatic test?

No. The F-ATI Test system is designed to perform its automatic functional test without interrupting the electrical supply to downstream equipment.

How many poles does the F-ATI4Test A-25/0.3 have?

The device has a 3P+N four-pole configuration for three-phase electrical systems with neutral.

Trusted Residual-Current Protection from ABB

ABB F-ATI Test RCCBs combine established residual-current protection technology with automatic testing, helping electrical installations maintain protective functionality while minimising disruption to connected equipment.