ABB F-ATI2Test A-63/0.03 is a 1P+N Type A residual current circuit breaker rated at 63 A with 30 mA residual-current sensitivity and automatic testing without interruption of the downstream electrical supply.
£749.03
The ABB F-ATI2Test A-63/0.03 is an advanced Type A residual current circuit breaker (RCCB) with automatic testing, designed to provide dependable residual-current protection while reducing the need for manual periodic testing. As part of the ABB F-ATI automatic-test RCCB range, it performs the required functional test automatically without interrupting power to the downstream circuit.
Periodic testing is important for verifying that an RCCB remains capable of operating correctly in the event of leakage to earth. The F-ATI range automates this process and performs the test without downtime, helping maintain continuity of service while reducing routine intervention by maintenance personnel. This makes it particularly suitable for commercial, industrial and infrastructure installations where disruption caused by manual RCCB testing is undesirable.
With a rated current of 63 A, a rated residual operating current of 30 mA and a 1P+N configuration, the F-ATI2Test A-63/0.03 provides Type A residual-current protection for single-phase circuits. Its 230 V AC rating and DIN-rail format enable straightforward integration into compatible electrical distribution boards and control panels.
Conventional RCCBs require periodic operation of their test mechanism to verify that the contacts and residual-current protection function remain operational. Performing this procedure manually can interrupt the circuits supplied downstream and requires maintenance personnel to access each device individually.
The ABB F-ATI range automates this periodic test while maintaining the downstream electrical supply. The F-ATI2Test A-63/0.03 therefore combines 63 A, 30 mA Type A residual-current protection with automatic testing, helping improve maintenance efficiency and continuity of service in installations where unnecessary electrical downtime should be minimised.
| Series | F-ATI Test |
|---|---|
| Product group | F200 / FH200 RCCB |
| ABB order code | 2CSF302130R1630 |
| EAN | 8012542289050 |
| Product type | RCCB with automatic test |
| Residual-current type | Type A |
| Number of poles | 1P+N / 2P |
| Rated current (In) | 63 A |
| Rated residual current (IΔn) | 30 mA |
| Rated voltage | 230 V AC |
| Surge-current withstand | 3 kA |
| Protection rating | IP20 |
| Pollution degree | 2 |
| Installation depth | 73.5 mm |
| Mounting type | DIN rail |
| Weight | approx. 0.55 kg |
The ABB F-ATI2Test A-63/0.03 provides Type A residual-current protection with automatic periodic testing for single-phase electrical circuits, helping verify RCCB operation without interrupting the downstream electrical supply.
The F-ATI2Test A-63/0.03 has a rated current of 63 A and a rated residual operating current of 30 mA.
The automatic test function periodically checks the operation of the RCCB without disconnecting the downstream electrical supply, reducing the need for manual testing while helping maintain continuity of service.
The device is a Type A RCCB, designed to detect sinusoidal AC residual currents as well as pulsating DC residual currents.
The ABB order code for the F-ATI2Test A-63/0.03 is 2CSF302130R1630.
ABB F-ATI automatic-test RCCBs combine residual-current protection with automatic functional testing without downstream downtime, helping electrical installations maintain protection while reducing the routine testing workload for maintenance personnel.