ABB F3C-AR230 C 4/30 is an automatic reclosing unit with preventive system checking for compatible 4-pole 30 mA F200 RCCBs up to 100 A, or Type B F200 RCCBs up to 63 A.
£321.67
The ABB F3C-AR230 C 4/30, order code 2CSF203998R0035, is an advanced automatic reclosing unit with system checking designed for compatible 4-pole ABB F200 residual current circuit breakers. As part of the ABB F200 / FH200 RCCB product group, it can automatically restore the associated RCCB after an unwanted trip, but only after checking that there is no effective fault remaining in the protected electrical system.
This version is specifically designed for 4-pole F200 RCCBs with 30 mA residual current sensitivity. Before reclosing, the F3C-AR230 C performs an assessment of the protected system, helping prevent reconnection while a genuine earth fault remains present. It supports compatible standard F200 RCCBs up to 100 A and Type B F200 RCCBs up to 63 A.
The unit operates from a 230–240 V AC supply and is intended for compatible 4-pole 400 V RCCB installations. Its automatic system-checking and reclosing functionality can improve continuity of service in commercial, industrial and unattended installations where restoring power safely after transient residual-current events is important.
The ABB F3C-AR230 C range is designed to improve continuity of supply while maintaining controlled residual current protection. Following an unexpected trip, the unit checks the protected electrical system before operating the associated RCCB. Automatic reclosing takes place only when the assessment indicates that no effective fault remains in the system.
For the F3C-AR230 C 4/30, this functionality is specifically configured for compatible 4-pole 30 mA F200 RCCBs. The unit can perform up to 48 automatic reclosing attempts and can continue assessing the installation for up to 24 hours after the fault, making it particularly useful where electrical continuity and unattended recovery are important.
| Series | F3C-AR230 C |
|---|---|
| Product group | F200 / FH200 RCCB |
| Manufacturer part number | F3CAR230C430 |
| ABB order code | 2CSF203998R0035 |
| Product type | Automatic reclosing unit with system check |
| Compatible RCCB poles | 4 |
| Compatible RCCB residual current | 30 mA |
| Compatible RCCB voltage | 400 V |
| Operating supply voltage | 230–240 V AC (-15% / +10%) |
| Compatible F200 rated current | Up to 100 A |
| Compatible F200 Type B rated current | Up to 63 A |
| Maximum automatic reclosing attempts | 48 |
| Waiting time between reclosing attempts | 45 s |
| System check availability | Up to 24 hours after fault |
| Nominal non-reclosing resistance Rd0 | 22 kΩ |
| Nominal reclosing resistance Rd | 8 kΩ |
| Suitable earthing systems | TT / TN |
| Power consumption during operation | <26 VA |
| Power consumption at rest | <1.5 VA |
| Closing time | <1 s |
| Opening time | <1 s |
| Number of modules | 1.5 |
| Protection rating | IP40 / IP20 |
| Pollution degree | 2 |
| Operating temperature | -25 to +60 °C |
| Terminal type | Plug-in connection |
| Tightening torque | 0.4 N·m |
| Dimensions (H × W × D) | 104.15 × 81.5 × 58.3 mm |
| Weight | approx. 0.13 kg |
| Standard | IEC/EN 63024 |
The ABB F3C-AR230 C 4/30 is an automatic reclosing unit with system checking for compatible 4-pole 30 mA ABB F200 RCCBs, designed to assess the protected system before automatically reclosing the associated device.
The unit is designed for compatible 4-pole 30 mA ABB F200 RCCBs up to 100 A, or up to 63 A for compatible F200 Type B RCCBs.
The automatic reclosing unit operates from a 230–240 V AC supply and is intended for compatible 4-pole 400 V RCCB applications.
Yes. The unit performs a preventive assessment of the protected system and only recloses the associated RCCB when its system check determines that there is no effective fault preventing reconnection.
The unit supports up to 48 automatic reclosing attempts, with a 45 s waiting time between attempts and system checking available for up to 24 hours after a fault.
ABB F3C-AR230 C automatic reclosing units combine automated RCCB operation with preventive system checking, helping improve continuity of supply while ensuring that reclosing is attempted only after assessment of the protected electrical system.