2CSF201998R0035 ABB F3C-AR230 C 2/30 Automatic Reclosing Unit 2P 30 mA

2CSF201998R0035 ABB F3C-AR230 C 2/30 Automatic Reclosing Unit 2P 30 mA

ABB F3C-AR230 C 2/30 is a 230–240 V AC automatic reclosing unit with system check for compatible 2-pole 30 mA F200 RCCBs, designed to verify the protected installation before automatic restoration.

SKU: 2CSF201998R0035Alt SKU: F3CAR230C230MPN: 2CSF201998R0035
Price
List Price £471.30 ex VAT
Your Price (ex VAT) Save 35%
£306.35 35% OFF
You save £164.96 per unit
Manufacturer Lead Time Estimated Delivery 10 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £306.35
Trade pricing is personalised to your account

Manufacturer Lead Time

£306.35

Why Choose the ABB F3C-AR230 C 2/30 Automatic Reclosing Unit?

The ABB F3C-AR230 C 2/30 is an advanced automatic reclosing unit with system check designed for compatible 2-pole ABB F200 residual current circuit breakers with a rated residual current of 30 mA. Identified by ABB order code 2CSF201998R0035, it automatically manages reclosing after unwanted tripping while first checking the protected installation for an active fault.

Unlike a basic automatic reclosing mechanism, the F3C-AR230 C series performs a system check before attempting to restore the associated RCCB. If a persistent fault is detected, reclosing is inhibited; if conditions permit restoration, the unit can automatically reclose the RCCB. This functionality helps improve continuity of service while maintaining the protective role of the residual current device.

The F3C-AR230 C 2/30 operates from a 230–240 V AC supply and is suitable for 2-pole F200 RCCBs rated at 30 mA, up to 100 A, or up to 63 A for compatible Type B RCCBs. Its compact 1.5-module format is designed for integration into modular low-voltage distribution assemblies.

Key Advantages

  • Automatic reclosing with system check before restoration of the protected circuit.
  • Designed for compatible 2-pole F200 30 mA RCCBs.
  • 230–240 V AC operating voltage for standard low-voltage installations.
  • Checks for an effective fault before attempting to reclose the associated RCCB.
  • Supports up to 48 automatic reclosing attempts according to its programmed reclosing sequence.
  • Helps improve continuity of service in unattended and critical electrical installations.

Key Features

  • ABB F3C-AR230 C 2/30 automatic reclosing unit.
  • ABB order code 2CSF201998R0035.
  • System-check functionality before automatic reclosing.
  • Suitable for 2-pole, 30 mA F200 RCCBs.
  • Suitable for F200 RCCBs up to 100 A and compatible Type B RCCBs up to 63 A.
  • 230–240 V AC operating voltage.
  • Compact 1.5-module format.
  • Up to 48 automatic reclosing attempts.
  • System monitoring can continue for up to 24 hours after a fault.
  • Complies with IEC/EN 63024.

Reliable Automatic Reclosing with System Verification

Residual current circuit breakers disconnect a protected circuit when qualifying leakage conditions occur. Some trips can result from temporary disturbances rather than persistent installation faults, but simply restoring power without checking the circuit could be inappropriate if a genuine fault remains.

The ABB F3C-AR230 C 2/30 addresses this requirement by checking the protected system before automatic reclosing. When no effective fault prevents restoration, the unit can reclose the associated RCCB according to its programmed sequence; when a persistent fault is identified, reclosing is blocked. This makes the unit particularly useful where continuity of service must be balanced with controlled fault verification.

Typical Applications

  • Unattended electrical installations.
  • Commercial and industrial distribution boards.
  • Building services and infrastructure systems.
  • Refrigeration and freezer circuits requiring continuity of supply.
  • Alarm, surveillance, gate and access-control systems.
  • Lighting and other installations where prolonged unnecessary outages should be minimised.

Technical Specifications

Series F3C-AR230 C
ABB order code 2CSF201998R0035
Product group F200 / FH200 RCCB
Product type Automatic reclosing unit with system check
Suitable for F200 RCCBs, 2-pole, 30 mA
Maximum compatible RCCB current 100 A
Maximum compatible Type B RCCB current 63 A
Operating voltage 230–240 V AC
Number of modules 1.5
Maximum automatic reclosing attempts 48
Active power consumption <26 VA
Standby power consumption <1.5 VA
Terminal type Plug-in connection
Terminal conductor size 0.2–2.5 mm²
Tightening torque 0.4 N·m
Operating temperature −25 to +60 °C
Pollution degree 2
Housing protection IP40
Terminal protection IP20
Dimensions (H × W × D) 104.15 × 81.5 × 58.3 mm
Weight 0.130 kg
Standard IEC/EN 63024

Frequently Asked Questions

What is the ABB F3C-AR230 C 2/30 used for?

The ABB F3C-AR230 C 2/30 is an automatic reclosing unit with system check that can automatically restore a compatible 2-pole 30 mA F200 RCCB after checking that no effective fault prevents reclosing.

Which RCCBs are compatible with the F3C-AR230 C 2/30?

It is designed for compatible 2-pole F200 RCCBs with 30 mA residual current sensitivity, up to 100 A, or up to 63 A for compatible Type B RCCBs.

What operating voltage does the F3C-AR230 C 2/30 require?

The unit operates from a 230–240 V AC supply.

Does the F3C-AR230 C 2/30 check for faults before reclosing?

Yes. The unit incorporates system-check functionality and only attempts automatic reclosing after checking the protected installation for an effective fault.

How many automatic reclosing attempts can the unit make?

The F3C-AR230 C series supports up to 48 automatic reclosing attempts according to its programmed reclosing sequence.

Trusted ABB Protection Accessories for Service Continuity

ABB F3C-AR230 C automatic reclosing units combine automatic restoration with system verification, helping compatible residual current protection installations maintain continuity of service without automatically reclosing onto a detected persistent fault.