2CSB204592R1400 ABB DDA204 B-40/0.03 AP-R RCD Block 4P 40A 30mA

2CSB204592R1400 ABB DDA204 B-40/0.03 AP-R RCD Block 4P 40A 30mA

ABB DDA204 B-40/0.03 AP-R is a four-pole 40 A Type B RCD block with 30 mA residual-current sensitivity and an AP-R high-immunity characteristic for circuits requiring AC, pulsating DC and smooth DC residual-current detection.

SKU: 2CSB204592R1400Alt SKU: DDA204B400.03APRMPN: 2CSB204592R1400
Price
List Price £1,336.90 ex VAT
Your Price (ex VAT) Save 35%
£868.99 35% OFF
You save £467.92 per unit
Manufacturer Lead Time Estimated Delivery 10 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £868.99
Trade pricing is personalised to your account

Manufacturer Lead Time

£868.99

Why Choose the ABB DDA204 B-40/0.03 AP-R RCD Block?

The ABB DDA204 B-40/0.03 AP-R is a four-pole Type B residual current device (RCD) block with ABB's AP-R high-immunity characteristic, designed for assembly with compatible ABB miniature circuit breakers. Part of the ABB DDA200 RCD block series, it provides residual-current protection for applications where a broader range of residual-current waveforms may occur.

Type B residual-current protection is designed to respond to sinusoidal AC, pulsating DC and smooth DC residual currents, making this device suitable for installations containing power-electronic equipment that can generate residual currents beyond the detection capability of Type AC or Type A devices. Its 30 mA rated residual operating current provides high-sensitivity protection, while the AP-R characteristic offers enhanced immunity against unwanted tripping.

With a 40 A rated current and four-pole configuration, the DDA204 B-40/0.03 AP-R is designed for multi-pole electrical circuits requiring Type B residual-current protection. When combined with a compatible ABB miniature circuit breaker, the resulting assembly provides residual-current protection alongside the MCB's overcurrent and short-circuit protection.

Key Advantages

  • Four-pole RCD block for multi-pole electrical circuits.
  • 40 A rated current for compatible ABB circuit protection assemblies.
  • 30 mA rated residual operating current for high-sensitivity residual-current protection.
  • Type B residual-current detection covers AC, pulsating DC and smooth DC residual currents.
  • AP-R high-immunity characteristic helps reduce unwanted operation caused by transient disturbances.
  • Designed for combination with compatible ABB miniature circuit breakers.

Key Features

  • ABB DDA200 RCD block series.
  • Four-pole configuration.
  • 40 A rated current.
  • 30 mA rated residual operating current.
  • Type B residual-current characteristic.
  • AP-R high-immunity characteristic.
  • Detection of sinusoidal AC, pulsating DC and smooth DC residual currents.
  • Suitable for circuits incorporating power-electronic equipment where Type B protection is specified.
  • Modular design for combination with compatible ABB MCBs.

Advanced Type B Residual-Current Protection

Electrical equipment incorporating rectifiers, inverters and other power-electronic circuitry can produce residual-current waveforms that include pulsating or smooth DC components. Type B residual-current protection extends detection beyond conventional AC residual currents, making it appropriate where these more complex residual-current forms can occur.

The DDA204 B-40/0.03 AP-R combines this broad Type B detection capability with a 30 mA sensitivity and ABB's AP-R high-immunity characteristic. This combination supports sensitive residual-current protection while providing increased resistance to transient disturbances that could otherwise result in unwanted operation.

Typical Applications

  • Commercial and industrial electrical distribution systems.
  • Four-pole circuits requiring 30 mA Type B residual-current protection.
  • Installations incorporating variable-speed drives and power converters.
  • Circuits containing inverter-based or other power-electronic equipment.
  • Applications where smooth DC residual currents may occur.
  • ABB modular circuit protection assemblies requiring enhanced immunity to transient disturbances.

Technical Specifications

Series DDA200
ABB order code 2CSB204592R1400
Product type Residual current device (RCD) block
Residual-current type B
Characteristic AP-R high immunity
Number of poles 4
Rated current 40 A
Rated residual operating current 30 mA
Residual-current detection Sinusoidal AC, pulsating DC and smooth DC
Applicable standard IEC/EN 61009 Annex G
Mounting DIN rail as part of a compatible modular circuit protection assembly

Frequently Asked Questions

What is the ABB DDA204 B-40/0.03 AP-R used for?

It is a four-pole Type B RCD block designed to provide 30 mA residual-current protection in circuits where AC, pulsating DC or smooth DC residual currents may occur, when assembled with a compatible ABB miniature circuit breaker.

What is the rated current of the DDA204 B-40/0.03 AP-R?

The ABB DDA204 B-40/0.03 AP-R has a rated current of 40 A.

What residual-current sensitivity does this RCD block provide?

It has a rated residual operating current of 30 mA.

What residual currents can a Type B RCD block detect?

Type B residual-current protection is designed to detect sinusoidal AC, pulsating DC and smooth DC residual currents, making it suitable for applications where power-electronic equipment can generate complex residual-current waveforms.

What does AP-R mean on this ABB RCD block?

The AP-R characteristic provides enhanced immunity to transient disturbances, helping reduce unwanted operation and improve continuity of service.

Trusted ABB Circuit Protection

ABB DDA200 Type B RCD blocks provide broad residual-current detection for modern electrical installations, while AP-R variants add enhanced immunity to transient disturbances for dependable modular circuit protection.