2CSB203101R5400 ABB DDA203A401 DDA203 A-40/1 RCD 3P Type A 1000mA 40A

2CSB203101R5400 ABB DDA203A401 DDA203 A-40/1 RCD 3P Type A 1000mA 40A

ABB DDA203A401 is a three-pole Type A DDA200 residual current device block rated at 40 A with 1000 mA residual current sensitivity for compatible ABB electrical protection assemblies.

SKU: 2CSB203101R5400Alt SKU: DDA203A401MPN: 2CSB203101R5400
Price
List Price £148.60 ex VAT
Your Price (ex VAT) Save 35%
£96.59 35% OFF
You save £52.01 per unit
Manufacturer Lead Time Estimated Delivery 8 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £96.59
Trade pricing is personalised to your account

Manufacturer Lead Time

£96.59

Why Choose the ABB DDA203A401 RCD Block?

The ABB DDA203A401 is a reliable Type A residual current device (RCD) block designed to provide residual current protection when coupled with compatible ABB miniature circuit breakers. As part of the established ABB DDA200 RCD series, this three-pole device is engineered for residential, commercial and industrial electrical distribution systems requiring dependable protection against earth leakage and residual currents.

This RCD block has a rated current of 40 A and a rated residual operating current of 1000 mA. Its Type A residual current characteristic provides sensitivity to sinusoidal AC residual currents as well as pulsating DC residual currents, making it suitable for electrical installations containing modern electronic and conventional loads.

The DDA203A401 is designed for coupling with compatible ABB System pro M compact circuit breakers, including the S200 series, to create a combined residual-current and overcurrent protection solution. Its three-pole configuration and 230/400 V AC rated voltage make it particularly suitable for three-phase electrical distribution applications.

Key Advantages

  • Reliable Type A residual current protection for three-phase electrical systems.
  • 40 A rated current for compatible distribution circuits.
  • 1000 mA rated residual operating current.
  • Three-pole configuration for three-phase applications.
  • Detects both sinusoidal AC and pulsating DC residual currents.
  • Designed to couple with compatible ABB System pro M compact miniature circuit breakers.

Key Features

  • ABB DDA200 RCD series.
  • Type A residual current characteristic.
  • 40 A rated current.
  • 1000 mA residual current sensitivity.
  • 3-pole design.
  • 230/400 V AC rated voltage.
  • 50–60 Hz rated frequency.
  • IP2X protection rating.
  • Designed for combination with compatible ABB S200 series miniature circuit breakers.

Reliable Residual Current Protection for Electrical Installations

Residual current devices monitor electrical circuits for current imbalance caused by leakage to earth. When used with a compatible circuit breaker, the ABB DDA200 system provides residual current protection alongside the overcurrent protection supplied by the associated protective device.

Type A RCD technology is designed to detect both sinusoidal alternating residual currents and pulsating direct residual currents. The DDA203A401 therefore provides dependable residual current detection for a broad range of residential, commercial and industrial electrical installations.

Typical Applications

  • Three-phase electrical distribution systems.
  • Industrial electrical control panels.
  • Commercial electrical installations.
  • Residential distribution applications.
  • Machinery and equipment distribution circuits.
  • Electrical circuits requiring Type A residual current protection.
  • ABB System pro M compact modular protection assemblies.

Technical Specifications

Series DDA200
SKU DDA203A401
ABB order code 2CSB203101R5400
EAN 8012542809203
Product type Residual current device (RCD) block
Residual current type Type A
Rated current 40 A
Rated residual current 1000 mA
Rated voltage 230/400 V AC
Number of poles 3
Rated frequency 50–60 Hz
Protection rating IP2X
Reference standard IEC/EN 61009 Annex G
Dimensions (W × H × D) 87 × 93 × 76 mm
Weight 220 g

Frequently Asked Questions

What is the ABB DDA203A401 used for?

The ABB DDA203A401 is a three-pole RCD block used with compatible ABB circuit breakers to provide Type A residual current protection in electrical distribution systems.

What is the rated current of the DDA203A401?

The DDA203A401 has a rated current of 40 A.

What residual current sensitivity does this RCD block provide?

The device has a rated residual operating current of 1000 mA.

What does Type A mean on the ABB DDA203A401?

Type A means the RCD is designed to detect sinusoidal AC residual currents as well as pulsating DC residual currents, providing protection suitable for many modern electrical loads.

How many poles does the ABB DDA203A401 have?

The DDA203A401 is a three-pole RCD block designed for use in compatible three-phase electrical protection assemblies.

Trusted Electrical Protection from ABB

ABB DDA200 residual current blocks form part of the System pro M compact protection range, providing dependable residual current protection for residential, commercial and industrial electrical applications when combined with compatible ABB protective devices.