2CSB203001R3250 ABB DDA203 AC-25/0.3 RCD Block 3P 25 A 300 mA Type AC

2CSB203001R3250 ABB DDA203 AC-25/0.3 RCD Block 3P 25 A 300 mA Type AC

ABB DDA203 AC-25/0.3 is a 3-pole Type AC residual current device block rated at 25 A with 300 mA residual current sensitivity for compatible low-voltage three-phase electrical protection assemblies.

SKU: 2CSB203001R3250Alt SKU: DDA203AC250.3MPN: 2CSB203001R3250
Price
List Price £113.05 ex VAT
Your Price (ex VAT) Save 35%
£73.48 35% OFF
You save £39.57 per unit
Manufacturer Lead Time Estimated Delivery 8 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £73.48
Trade pricing is personalised to your account

Manufacturer Lead Time

£73.48

Why Choose the ABB DDA203 AC-25/0.3 RCD Block?

The ABB DDA203 AC-25/0.3, order code 2CSB203001R3250, is a compact 3-pole Type AC residual current device (RCD) block designed for assembly with compatible ABB miniature circuit breakers. As part of the ABB DDA200 RCD series, it provides residual current protection for low-voltage electrical installations requiring detection of sinusoidal alternating residual currents.

This Type AC RCD block has a 25 A rated current and a 300 mA rated residual operating current. Its three-pole configuration makes it suitable for compatible three-phase circuit protection arrangements in commercial and industrial electrical distribution systems.

With a 230 V rated voltage, 50/60 Hz rated frequency and modular construction, the DDA203 AC-25/0.3 provides a practical residual current protection solution. When assembled with a compatible ABB miniature circuit breaker, the RCD block provides earth fault protection while the associated MCB provides overcurrent and short-circuit protection.

Key Advantages

  • Compact 3-pole RCD block for residual current protection.
  • 25 A rated current for compatible low-voltage circuits.
  • 300 mA rated residual operating current.
  • Type AC detection for sinusoidal alternating residual currents.
  • Suitable for compatible three-phase electrical protection arrangements.
  • Designed for assembly with compatible ABB miniature circuit breakers.

Key Features

  • ABB DDA200 RCD series.
  • 3-pole configuration.
  • 25 A rated current.
  • 300 mA rated residual current.
  • Type AC residual current detection.
  • 230 V rated voltage.
  • 500 V rated insulation voltage.
  • 4 kV rated impulse withstand voltage.
  • 50/60 Hz rated frequency.
  • IP2X degree of protection.
  • Interlocking device for assembly with the associated miniature circuit breaker.
  • Designed for modular low-voltage electrical distribution systems.

Type AC Residual Current Protection for Three-Phase Circuits

Type AC residual current protection is designed to respond to sinusoidal alternating residual currents. The ABB DDA203 AC-25/0.3 provides this protection in a 3-pole configuration, making it suitable for compatible three-phase electrical circuits where Type AC protection is appropriate for the connected equipment and installation requirements.

The 300 mA residual current rating makes this model suitable for installations where this level of earth fault protection is specified. When correctly assembled with a compatible ABB miniature circuit breaker, the DDA203 AC-25/0.3 provides residual current protection while the associated MCB provides the required overcurrent and short-circuit protection.

Typical Applications

  • Commercial three-phase electrical distribution systems.
  • Industrial electrical installations.
  • Three-phase distribution and control panels.
  • Circuits requiring 300 mA Type AC residual current protection.
  • Compatible three-phase circuits rated up to 25 A.
  • Protection assemblies using compatible ABB miniature circuit breakers.

Technical Specifications

Series DDA200
Order code 2CSB203001R3250
Product group DDA200 RCD
Product type Residual current device block
Residual current type Type AC
Rated current 25 A
Rated residual current 300 mA (0.3 A)
Rated voltage 230 V
Rated insulation voltage 500 V
Rated impulse withstand voltage 4 kV
Number of poles 3
Frequency 50/60 Hz
Protection rating IP2X
Electrical endurance 10,000 cycles
Connectable conductor cross-section up to 16 mm²
Operating ambient temperature -25 to +55 °C
Standard IEC/EN 61009 Annex G
Dimensions (W × H × D) 87 × 93 × 76 mm
Catalogue weight approx. 0.22 kg

Frequently Asked Questions

What is the ABB DDA203 AC-25/0.3 used for?

The ABB DDA203 AC-25/0.3 is a 3-pole Type AC RCD block designed for assembly with a compatible miniature circuit breaker to provide 300 mA residual current protection in suitable low-voltage three-phase electrical installations.

What is the rated current of the ABB DDA203 AC-25/0.3?

The DDA203 AC-25/0.3 has a rated current of 25 A.

What is the residual current sensitivity of this RCD block?

The device has a rated residual operating current of 300 mA, equivalent to 0.3 A.

What does Type AC mean on the ABB DDA203 AC-25/0.3?

Type AC means the RCD block is designed to respond to sinusoidal alternating residual currents. Its suitability should be determined according to the connected equipment and the requirements of the electrical installation.

Can the ABB DDA203 AC-25/0.3 be used on its own as a circuit breaker?

No. The DDA203 AC-25/0.3 is an RCD block designed for assembly with a compatible miniature circuit breaker, which provides the associated overcurrent and short-circuit protection.

Trusted ABB Circuit Protection Technology

ABB DDA200 Type AC RCD blocks provide modular residual current protection for low-voltage electrical installations, with the DDA203 range offering three-pole solutions for compatible three-phase circuit protection assemblies.